Perimodiolar electrodes in cochlear implant surgery.

W K Gstoettner1, O Adunka, P Franz, J Hamzavi, H Plenk, M Susani, W Baumgartner, J Kiefer.   

Abstract

Perimodiolar-positioned cochlear implant electrodes have been developed in order to bring the electrode contacts as close as possible to the spiral ganglion cells, which are the target of electrostimulation. This results in lower electrical thresholds, higher dynamic ranges and less channel interaction when compared with normal implant electrodes which are usually located peripherally within the scala tympani. In this study we evaluated 4 different types of perimodiolar electrode: the Clarion Preformed electrode, the Clarion Preformed electrode with positioner, the Nucleus Contour electrode and the Med-El Perimodiolar Combi 40 electrode. These devices require different approaches to achieve a perimodiolar electrode position. The electrodes were inserted in fresh human temporal bones. After processing these bones with the electrodes in situ by employing a sawing, grinding and polishing technique, the inner ear structures as well as the electrode positions could be evaluated in detail. All electrode types studied had a more or less perimodiolar position; however, each type produced a certain amount of trauma to cochlear structures which is discussed in relation to mechanical properties. Further human temporal bone studies with improved perimodiolar cochlear implant electrodes are necessary in order to find an optimized type of electrode.

Entities:  

Mesh:

Year:  2001        PMID: 11349782     DOI: 10.1080/000164801300043569

Source DB:  PubMed          Journal:  Acta Otolaryngol        ISSN: 0001-6489            Impact factor:   1.494


  18 in total

1.  Complication of cochlear implantation surgery.

Authors:  Michael A Mecca; William Wagle; Allison Lupinetti; Steven Parnes
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

Review 2.  [Current developments in cochlear implantation].

Authors:  R Laszig; A Aschendorff; J Schipper; T Klenzner
Journal:  HNO       Date:  2004-04       Impact factor: 1.284

3.  Intra-Operative Neural Response Telemetry and Acoustic Reflex Assessment using an Advance-In-Stylet Technique and Modiolus-Hugging: A prospective cohort study.

Authors:  Abdulrahman Hagr
Journal:  Sultan Qaboos Univ Med J       Date:  2011-08-15

4.  [Vestibular dysfunction after cochlear implant in adults].

Authors:  F Holinski; F Elhajzein; G Scholz; B Sedlmaier
Journal:  HNO       Date:  2012-10       Impact factor: 1.284

5.  [Cochlear implantation with preservation of residual deep frequency hearing].

Authors:  W Gstöttner; S-M Pok; S Peters; J Kiefer; O Adunka
Journal:  HNO       Date:  2005-09       Impact factor: 1.284

6.  Modelling encapsulation tissue around cochlear implant electrodes.

Authors:  T Hanekom
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

7.  Cochlear Histopathology as Observed in Two Patients With a Cochlear Implant Electrode With Positioner.

Authors:  Takefumi Kamakura; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2016-07       Impact factor: 2.311

8.  Vestibulo-ocular reflex responses to a multichannel vestibular prosthesis incorporating a 3D coordinate transformation for correction of misalignment.

Authors:  Gene Y Fridman; Natan S Davidovics; Chenkai Dai; Americo A Migliaccio; Charles C Della Santina
Journal:  J Assoc Res Otolaryngol       Date:  2010-02-23

9.  Would an endosteal CI-electrode make sense? Comparison of the auditory nerve excitability from different stimulation sites using ESRT measurements and mathematical models.

Authors:  Hans Wilhelm Pau; Annekathrin Grünbaum; Karsten Ehrt; Rüdiger Dahl; Tino Just; Ursula van Rienen
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-05-09       Impact factor: 2.503

10.  Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography.

Authors:  Aarno Dietz; Dzemal Gazibegovic; Jyrki Tervaniemi; Veli-Matti Vartiainen; Heikki Löppönen
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-05-19       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.