Clarion 1.2 standard electrode array with partial space-filling positioner: radiological and histological evaluation in human temporal bones.

Bernhard Richter1, Antje Aschendorff, Petra Lohnstein, Hartmut Husstedt, Heiner Nagursky, Roland Laszig.   

Abstract

The purpose of this study was to evaluate whether use of a positioner for situating the Clarion 1.29 standard electrode array in close proximity to the modiolus, causes damage to fine intra-cochlear structures, and to provide a comparison with results obtained for insertions of the array performed without a positioner. The study was performed in seven freshly frozen human temporal bones. Electrode location and intra-cochlear trauma was analysed using cross-sectional imaging and histological analysis. Insertion of the Clarion array did not reveal major trauma. The devices inserted with the positioner showed a consistently closer location of the electron array towards the modiolus, however, insertion resulted in significant displacement of both the electrode array and the positioner resulting in severe destruction of the basilar membrane and osseous spiral lamina along the length of the basal and middle turns. The devices inserted with the positioner resulted in major trauma to the basilar membrane and osseous spiral lamina. Therefore, systematic safety studies in larger samples of human temporal bones should be performed and the results carefully evaluated before implantation can be recommended unreservedly.

Entities:  

Mesh:

Year:  2002        PMID: 12238669     DOI: 10.1258/002221502760132584

Source DB:  PubMed          Journal:  J Laryngol Otol        ISSN: 0022-2151            Impact factor:   1.469


  8 in total

Review 1.  [Current developments in cochlear implantation].

Authors:  R Laszig; A Aschendorff; J Schipper; T Klenzner
Journal:  HNO       Date:  2004-04       Impact factor: 1.284

2.  Predicting the effect of post-implant cochlear fibrosis on residual hearing.

Authors:  Chul-Hee Choi; John S Oghalai
Journal:  Hear Res       Date:  2005-07       Impact factor: 3.208

3.  [Cochlear implants in isolated temporal bones: evaluation of electrode position with 64-slice computed tomography].

Authors:  J H Wagner; G Rademacher; A Ernst; I Todt
Journal:  HNO       Date:  2009-06       Impact factor: 1.284

4.  The pattern and degree of capsular fibrous sheaths surrounding cochlear electrode arrays.

Authors:  Reuven Ishai; Barbara S Herrmann; Joseph B Nadol; Alicia M Quesnel
Journal:  Hear Res       Date:  2017-02-17       Impact factor: 3.208

5.  Cochlear Histopathology as Observed in Two Patients With a Cochlear Implant Electrode With Positioner.

Authors:  Takefumi Kamakura; Joseph B Nadol
Journal:  Otol Neurotol       Date:  2016-07       Impact factor: 2.311

Review 6.  Cochlear implants: system design, integration, and evaluation.

Authors:  Fan-Gang Zeng; Stephen Rebscher; William Harrison; Xiaoan Sun; Haihong Feng
Journal:  IEEE Rev Biomed Eng       Date:  2008-11-05

7.  Histopathology of the Clarion cochlear implant electrode positioner in a human subject.

Authors:  M Seyyedi; B J Burgess; D K Eddington; B J Gantz; J B Nadol
Journal:  Audiol Neurootol       Date:  2013-06-14       Impact factor: 1.854

8.  Technical devices for hearing-impaired individuals: cochlear implants and brain stem implants - developments of the last decade.

Authors:  Joachim Müller
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2005-09-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.