Martin Stuschke, Andreas Kaiser, Jehad Abu Jawad, Christoph Pöttgen, Sabine Levegrün, Jonathan Farr.
Abstract
BACKGROUND: In a previous report, we compared the conformity of robust intensity-modulated proton therapy (IMPT) plans with that of helical tomotherapy plans for re-irradiations of head and neck carcinomas using a fixed set-up error of 2 mm. Here, we varied the maximum set-up errors between 0 and 5 mm and compared the robust IMPT-plans with planning target volume (PTV) based intensity-modulated photon therapy (IMRT).Entities:
Mesh:
Year: 2013 PMID: 23773560 PMCID: PMC3695849 DOI: 10.1186/1748-717X-8-145
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Figure 1Exposed body volumes. Body volumes exposed to doses higher than x% of the prescribed dose (Vbodyx%) in robust IMPT-plans assuming set-up errors of 0, 2, and 5 mm around the target volume derived from the original PTV through isotropic shrinkage by set-up margins of 0, 2, and 5 mm, respectively, for 7 patients with recurrent head and neck carcinomas and evaluated isodose levels x between 20% and 95%. The ratios of Vbodyx% in the 0 and 5 mm IMPT-plans (IMPT5mm and IMPT0mm, respectively) over Vbodyx% exposed in the 2 mm IMPT-plan (IMPT2mm) are displayed by red circles and green triangles, respectively. A significant decrease of −11.9 ± 0.8% in Vbodyx% in the robust IMPT5mm-plan was obtained in comparison with Vbodyx% exposed in the robust IMPT2mm-plan (p < 0.0001, F-Test). The respective increase in Vbodyx% in the IMPT0mm-plan was 6.2 ± 0.9% (p < 0.0001, F-Test).
Figure 2Dose difference plots. Distribution of the dose difference obtained by subtracting the dose distribution of the IMPT2mm-plan from the dose distributions of the IMPT0mm- and the IMPT5mm-plans. (a1) Dose difference IMPT0mm-IMPT2mm for patient 1. (a2) Dose difference IMPT5mm-IMPT2mm for patient 1. The corresponding dose difference plots for patient 7 are shown in (b1) and (b2), respectively.
Figure 3Normal tissue exposure. Mean dose difference to the ipsilateral temporal lobe and the cerebellum between the IMPT0mm- and IMPT2mm-plans (red circles) and between the IMPT5mm- and IMPT2mm-plans (green triangles) for the 7 patients (left vertical axis). The respective differences in D2%, quantifying hot spots in the serial organ of each patient exposed to the highest doses, i.e. the either brain stem or the spinal cord, are also shown (right vertical axis).