PURPOSE: To report a method for explicitly designing a planning target volume (PTV) for treatment planning and evaluation in heterogeneous media for passively scattered proton therapy and scanning beam proton therapy using single-field optimization (SFO). METHODS AND MATERIALS: A beam-specific PTV (bsPTV) for proton beams was derived by ray-tracing and shifting ray lines to account for tissue misalignment in the presence of setup error or organ motion. Range uncertainties resulting from inaccuracies in computed tomography-based range estimation were calculated for proximal and distal surfaces of the target in the beam direction. The bsPTV was then constructed based on local heterogeneity. The bsPTV thus can be used directly as a planning target as if it were in photon therapy. To test the robustness of the bsPTV, we generated a single-field proton plan in a virtual phantom. Intentional setup and range errors were introduced. Dose coverage to the clinical target volume (CTV) under various simulation conditions was compared between plans designed based on the bsPTV and a conventional PTV. RESULTS: The simulated treatment using the bsPTV design performed significantly better than the plan using the conventional PTV in maintaining dose coverage to the CTV. With conventional PTV plans, the minimum coverage to the CTV dropped from 99% to 67% in the presence of setup error, internal motion, and range uncertainty. However, plans using the bsPTV showed minimal drop of target coverage from 99% to 94%. CONCLUSIONS: The conventional geometry-based PTV concept used in photon therapy does not work well for proton therapy. We investigated and validated a beam-specific PTV method for designing and evaluating proton plans.
PURPOSE: To report a method for explicitly designing a planning target volume (PTV) for treatment planning and evaluation in heterogeneous media for passively scattered proton therapy and scanning beam proton therapy using single-field optimization (SFO). METHODS AND MATERIALS: A beam-specific PTV (bsPTV) for proton beams was derived by ray-tracing and shifting ray lines to account for tissue misalignment in the presence of setup error or organ motion. Range uncertainties resulting from inaccuracies in computed tomography-based range estimation were calculated for proximal and distal surfaces of the target in the beam direction. The bsPTV was then constructed based on local heterogeneity. The bsPTV thus can be used directly as a planning target as if it were in photon therapy. To test the robustness of the bsPTV, we generated a single-field proton plan in a virtual phantom. Intentional setup and range errors were introduced. Dose coverage to the clinical target volume (CTV) under various simulation conditions was compared between plans designed based on the bsPTV and a conventional PTV. RESULTS: The simulated treatment using the bsPTV design performed significantly better than the plan using the conventional PTV in maintaining dose coverage to the CTV. With conventional PTV plans, the minimum coverage to the CTV dropped from 99% to 67% in the presence of setup error, internal motion, and range uncertainty. However, plans using the bsPTV showed minimal drop of target coverage from 99% to 94%. CONCLUSIONS: The conventional geometry-based PTV concept used in photon therapy does not work well for proton therapy. We investigated and validated a beam-specific PTV method for designing and evaluating proton plans.
Authors: Jeff Meyer; Jaques Bluett; Richard Amos; Larry Levy; Seungtaek Choi; Quynh-Nhu Nguyen; X Ron Zhu; Michael Gillin; Andrew Lee Journal: Int J Radiat Oncol Biol Phys Date: 2010-01-25 Impact factor: 7.038
Authors: Wenbo Gu; Dan Ruan; Daniel O'Connor; Wei Zou; Lei Dong; Min-Yu Tsai; Xun Jia; Ke Sheng Journal: Med Phys Date: 2019-01-21 Impact factor: 4.071
Authors: Wei Liu; Radhe Mohan; Peter Park; Zhong Liu; Heng Li; Xiaoqiang Li; Yupeng Li; Richard Wu; Narayan Sahoo; Lei Dong; X Ronald Zhu; David R Grosshans Journal: Pract Radiat Oncol Date: 2014-01-14
Authors: Steven J Frank; James D Cox; Michael Gillin; Radhe Mohan; Adam S Garden; David I Rosenthal; G Brandon Gunn; Randal S Weber; Merrill S Kies; Jan S Lewin; Mark F Munsell; Matthew B Palmer; Narayan Sahoo; Xiaodong Zhang; Wei Liu; X Ronald Zhu Journal: Int J Radiat Oncol Biol Phys Date: 2014-05-24 Impact factor: 7.038
Authors: Joey P Cheung; Peter C Park; Laurence E Court; X Ronald Zhu; Rajat J Kudchadker; Steven J Frank; Lei Dong Journal: Med Phys Date: 2013-05 Impact factor: 4.071
Authors: Wei Liu; Steven J Frank; Xiaoqiang Li; Yupeng Li; Peter C Park; Lei Dong; X Ronald Zhu; Radhe Mohan Journal: Med Phys Date: 2013-05 Impact factor: 4.071