Literature DB >> 21709340

Is it necessary to plan with safety margins for actively scanned proton therapy?

F Albertini1, E B Hug, A J Lomax.   

Abstract

In radiation therapy, a plan is robust if the calculated and the delivered dose are in agreement, even in the case of different uncertainties. The current practice is to use safety margins, expanding the clinical target volume sufficiently enough to account for treatment uncertainties. This, however, might not be ideal for proton therapy and in particular when using intensity modulated proton therapy (IMPT) plans as degradation in the dose conformity could also be found in the middle of the target resulting from misalignments of highly in-field dose gradients. Single field uniform dose (SFUD) and IMPT plans have been calculated for different anatomical sites and the need for margins has been assessed by analyzing plan robustness to set-up and range uncertainties. We found that the use of safety margins is a good way to improve plan robustness for SFUD and IMPT plans with low in-field dose gradients but not necessarily for highly modulated IMPT plans for which only a marginal improvement in plan robustness could be detected through the definition of a planning target volume.

Mesh:

Substances:

Year:  2011        PMID: 21709340     DOI: 10.1088/0031-9155/56/14/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

1.  Robust optimization of intensity modulated proton therapy.

Authors:  Wei Liu; Xiaodong Zhang; Yupeng Li; Radhe Mohan
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

2.  Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques.

Authors:  Wei Liu; Yupeng Li; Xiaoqiang Li; Wenhua Cao; Xiaodong Zhang
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

Review 3.  Robust Proton Treatment Planning: Physical and Biological Optimization.

Authors:  Jan Unkelbach; Harald Paganetti
Journal:  Semin Radiat Oncol       Date:  2018-04       Impact factor: 5.934

4.  Robust optimization for intensity-modulated proton therapy with soft spot sensitivity regularization.

Authors:  Wenbo Gu; Dan Ruan; Daniel O'Connor; Wei Zou; Lei Dong; Min-Yu Tsai; Xun Jia; Ke Sheng
Journal:  Med Phys       Date:  2019-01-21       Impact factor: 4.071

Review 5.  Robustness Analysis for External Beam Radiation Therapy Treatment Plans: Describing Uncertainty Scenarios and Reporting Their Dosimetric Consequences.

Authors:  Adam D Yock; Radhe Mohan; Stella Flampouri; Walter Bosch; Paige A Taylor; David Gladstone; Siyong Kim; Jason Sohn; Robert Wallace; Ying Xiao; Jeff Buchsbaum
Journal:  Pract Radiat Oncol       Date:  2018-12-15

6.  PET/CT-guided treatment planning for paediatric cancer patients: a simulation study of proton and conventional photon therapy.

Authors:  J S Kornerup; N P Brodin; T Björk-Eriksson; C Birk Christensen; A Kiil-Berthelsen; M C Aznar; C Hollensen; E Markova; P Munck Af Rosenschöld
Journal:  Br J Radiol       Date:  2014-12-12       Impact factor: 3.039

Review 7.  Treatment planning optimisation in proton therapy.

Authors:  S E McGowan; N G Burnet; A J Lomax
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

8.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

9.  Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.

Authors:  Wenbo Gu; Daniel O'Connor; Dan Nguyen; Victoria Y Yu; Dan Ruan; Lei Dong; Ke Sheng
Journal:  Med Phys       Date:  2018-03-01       Impact factor: 4.071

10.  Site-specific range uncertainties caused by dose calculation algorithms for proton therapy.

Authors:  J Schuemann; S Dowdell; C Grassberger; C H Min; H Paganetti
Journal:  Phys Med Biol       Date:  2014-07-03       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.