Varying kVp as a means of reducing CT breast dose to pediatric patients.

K B Mathieu1, A C Turner, M Khatonabadi, M F McNitt-Gray, C H Cagnon, D D Cody.   

Abstract

We investigated the possibility of reducing radiation dose to the breast tissue of pediatric females by using multiple tube voltages within a single CT examination. The peak kilovoltage (kVp) was adjusted when the x-ray beam was directly exposing the representative breast tissue of a 5-year-old, 10-year-old, and an adult female anthropomorphic phantom; this strategy was called kVp splitting and was emulated by using a different kVp over the anterior and posterior tube angles. Dose savings from kVp splitting were calculated relative to using a fixed kVp over all tube angles and the results indicated savings in all three phantoms when using 80 kVp over the posterior tube angles regardless of the anterior kVp. Monte Carlo (MC) simulations with and without kVp splitting were performed to estimate absorbed breast dose in voxelized models constructed from the CT images of pediatric female patients; 80 kVp was used over the posterior tube angles. The MC simulations revealed breast dose savings of between 9.8% and 33% from using kVp splitting compared to simulations using a fixed kVp protocol with the anterior technique. Before this strategy could be implemented clinically, the development of suitable image reconstruction algorithms and the image quality of scans with kVp splitting would need further study.

Entities:  

Mesh:

Year:  2013        PMID: 23756499      PMCID: PMC3920986          DOI: 10.1088/0031-9155/58/13/4455

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers.

Authors:  W A Kalender; H Wolf; C Suess; M Gies; H Greess; W A Bautz
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

2.  Multi-detector row CT: radiation dose characteristics.

Authors:  Leena M Hamberg; James T Rhea; George J Hunter; James H Thrall
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 4.  Radiation dose reduction in chest CT: a review.

Authors:  Takeshi Kubo; Pei-Jan Paul Lin; Wolfram Stiller; Masaya Takahashi; Hans-Ulrich Kauczor; Yoshiharu Ohno; Hiroto Hatabu
Journal:  AJR Am J Roentgenol       Date:  2008-02       Impact factor: 3.959

Review 5.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

6.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

7.  Water calibration for CT scanners with tube voltage modulation.

Authors:  Ludwig Ritschl; Frank Bergner; Christof Fleischmann; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2010-07-05       Impact factor: 3.609

8.  Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations.

Authors:  Sabrina V Vollmar; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-04-15       Impact factor: 5.315

9.  Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT.

Authors:  Erin Angel; Nazanin Yaghmai; Cecilia Matilda Jude; John J Demarco; Christopher H Cagnon; Jonathan G Goldin; Andrew N Primak; Donna M Stevens; Dianna D Cody; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Phys Med Biol       Date:  2009-01-06       Impact factor: 3.609

10.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose.

Authors:  J J DeMarco; C H Cagnon; D D Cody; D M Stevens; C H McCollough; M Zankl; E Angel; M F McNitt-Gray
Journal:  Phys Med Biol       Date:  2007-04-17       Impact factor: 3.609

View more
  1 in total

1.  Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction.

Authors:  Kuei-Yuan Hou; Katsumi Tsujioka; Ching-Ching Yang
Journal:  J Appl Clin Med Phys       Date:  2019-12-30       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.