Literature DB >> 23736612

Translation position determination in ptychographic coherent diffraction imaging.

Fucai Zhang1, Isaac Peterson, Joan Vila-Comamala, Ana Diaz, Felisa Berenguer, Richard Bean, Bo Chen, Andreas Menzel, Ian K Robinson, John M Rodenburg.   

Abstract

Accurate knowledge of translation positions is essential in ptychography to achieve a good image quality and the diffraction limited resolution. We propose a method to retrieve and correct position errors during the image reconstruction iterations. Sub-pixel position accuracy after refinement is shown to be achievable within several tens of iterations. Simulation and experimental results for both optical and X-ray wavelengths are given. The method improves both the quality of the retrieved object image and relaxes the position accuracy requirement while acquiring the diffraction patterns.

Year:  2013        PMID: 23736612     DOI: 10.1364/OE.21.013592

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  23 in total

1.  3D X-Ray Imaging of Continuous Objects beyond the Depth of Focus Limit.

Authors:  M A Gilles; Y S G Nashed; M DU; C Jacobsen; S M Wild
Journal:  Optica       Date:  2018-09-20       Impact factor: 11.104

2.  Parallel ptychographic reconstruction.

Authors:  Youssef S G Nashed; David J Vine; Tom Peterka; Junjing Deng; Rob Ross; Chris Jacobsen
Journal:  Opt Express       Date:  2014-12-29       Impact factor: 3.894

3.  Ultra-high speed digital micro-mirror device based ptychographic iterative engine method.

Authors:  Aihui Sun; Xiaoliang He; Yan Kong; Haoyang Cui; Xiaojun Song; Liang Xue; Shouyu Wang; Cheng Liu
Journal:  Biomed Opt Express       Date:  2017-06-07       Impact factor: 3.732

4.  High-resolution three-dimensional structural microscopy by single-angle Bragg ptychography.

Authors:  S O Hruszkewycz; M Allain; M V Holt; C E Murray; J R Holt; P H Fuoss; V Chamard
Journal:  Nat Mater       Date:  2016-11-21       Impact factor: 43.841

5.  Coherent x-ray imaging of collagen fibril distributions within intact tendons.

Authors:  Felisa Berenguer; Richard J Bean; Laurent Bozec; Joan Vila-Comamala; Fucai Zhang; Cameron M Kewish; Oliver Bunk; John M Rodenburg; Ian K Robinson
Journal:  Biophys J       Date:  2014-01-21       Impact factor: 4.033

6.  Opportunities and limitations for combined fly-scan ptychography and fluorescence microscopy.

Authors:  Junjing Deng; David J Vine; Si Chen; Youssef S G Nashed; Tom Peterka; Rob Ross; Stefan Vogt; Chris Jacobsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-09-18

7.  Efficient positional misalignment correction method for Fourier ptychographic microscopy.

Authors:  Jiasong Sun; Qian Chen; Yuzhen Zhang; Chao Zuo
Journal:  Biomed Opt Express       Date:  2016-03-17       Impact factor: 3.732

8.  Adorym: a multi-platform generic X-ray image reconstruction framework based on automatic differentiation.

Authors:  Ming Du; Saugat Kandel; Junjing Deng; Xiaojing Huang; Arnaud Demortiere; Tuan Tu Nguyen; Remi Tucoulou; Vincent De Andrade; Qiaoling Jin; Chris Jacobsen
Journal:  Opt Express       Date:  2021-03-29       Impact factor: 3.894

9.  Quantitative electron phase imaging with high sensitivity and an unlimited field of view.

Authors:  A M Maiden; M C Sarahan; M D Stagg; S M Schramm; M J Humphry
Journal:  Sci Rep       Date:  2015-10-01       Impact factor: 4.379

10.  X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution.

Authors:  M Holler; A Diaz; M Guizar-Sicairos; P Karvinen; Elina Färm; Emma Härkönen; Mikko Ritala; A Menzel; J Raabe; O Bunk
Journal:  Sci Rep       Date:  2014-01-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.