Literature DB >> 23728433

Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department.

M Kennedy Hall1, David M Spiro, Alfredo Sabbaj, Christopher L Moore, Katharine L Hopkins, Garth D Meckler.   

Abstract

OBJECTIVE: To determine the feasibility and test characteristics of optic nerve sheath diameter (ONSD) measured by ocular ultrasound as a screening tool for ventriculoperitoneal shunt (VPS) failure.
METHODS: Prospective observational study using a convenience sample of children 6 months to 18 years of age, presenting to an academic pediatric emergency department for evaluation of possible VPS failure between September 2008 and March 2009. ONSD was measured by anterior transbulbar and lateral transbulbar techniques. Mean ONSD was compared between subjects with and without shunt failure, as determined by neurosurgical decision to operate.
RESULTS: A total of 39 encounters were completed, including 20 VPS failures. The mean ONSD was 4.5 ± 0.9 and 5.0 ± 0.6 mm among encounters with and without shunt failure (p = 0.03), respectively. The mean ONSD was not statistically different when obtained by the anterior transbulbar vs. the lateral transbulbar approach (4.8 ± 1.0 vs. 4.7 ± 0.8 mm, p = 0.12). ONSD ultrasound had a sensitivity of 61.1 % (95 % CI 35.7-82.7) and specificity of 22.2 % (95 % CI 6.4-47.6 %) for detecting shunt failure in this sample.
CONCLUSIONS: ONSD ultrasound does not appear to be a useful primary screening tool in emergency department evaluation of VPS failure. There was no difference between the anterior transbulbar approach and the lateral transbulbar approach. Children with VPS in our sample have larger ONSD measurements than in previously reported studies.

Entities:  

Mesh:

Year:  2013        PMID: 23728433     DOI: 10.1007/s00381-013-2172-y

Source DB:  PubMed          Journal:  Childs Nerv Syst        ISSN: 0256-7040            Impact factor:   1.475


  16 in total

1.  Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.

Authors:  Vivek S Tayal; Matthew Neulander; H James Norton; Troy Foster; Timothy Saunders; Michael Blaivas
Journal:  Ann Emerg Med       Date:  2006-09-25       Impact factor: 5.721

2.  Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests.

Authors:  H C Hansen; K Helmke
Journal:  J Neurosurg       Date:  1997-07       Impact factor: 5.115

3.  Optic nerve ultrasound: artifacts and real images.

Authors:  Roberto Copetti; Luigi Cattarossi
Journal:  Intensive Care Med       Date:  2009-04-15       Impact factor: 17.440

4.  Signs and symptoms of cerebrospinal fluid shunt malfunction in the pediatric emergency department.

Authors:  Tommy Y Kim; Gail Stewart; Marcus Voth; James A Moynihan; Lance Brown
Journal:  Pediatr Emerg Care       Date:  2006-01       Impact factor: 1.454

5.  Standardized echography of the eye and orbit.

Authors:  S F Byrne
Journal:  Neuroradiology       Date:  1986       Impact factor: 2.804

6.  Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.

Authors:  W D Newman; A S Hollman; G N Dutton; R Carachi
Journal:  Br J Ophthalmol       Date:  2002-10       Impact factor: 4.638

7.  Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus.

Authors:  David McAuley; Anne Paterson; Louise Sweeney
Journal:  Childs Nerv Syst       Date:  2008-09-23       Impact factor: 1.475

8.  Emergency department evaluation of ventricular shunt malfunction: is the shunt series really necessary?

Authors:  Raymond Pitetti
Journal:  Pediatr Emerg Care       Date:  2007-03       Impact factor: 1.454

9.  Time-related patterns of ventricular shunt failure.

Authors:  J Kast; D Duong; F Nowzari; W M Chadduck; S J Schiff
Journal:  Childs Nerv Syst       Date:  1994-11       Impact factor: 1.475

10.  Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study.

Authors:  Mark S Pearce; Jane A Salotti; Mark P Little; Kieran McHugh; Choonsik Lee; Kwang Pyo Kim; Nicola L Howe; Cecile M Ronckers; Preetha Rajaraman; Alan W Sir Craft; Louise Parker; Amy Berrington de González
Journal:  Lancet       Date:  2012-06-07       Impact factor: 79.321

View more
  11 in total

Review 1.  CT scan exposure in children with ventriculo-peritoneal shunts: single centre experience and review of the literature.

Authors:  Gareth M Dobson; Arthur K Dalton; Claire L Nicholson; Alistair J Jenkins; Patrick B Mitchell; Christopher J A Cowie
Journal:  Childs Nerv Syst       Date:  2019-08-19       Impact factor: 1.475

Review 2.  Pediatric emergency medicine point-of-care ultrasound: summary of the evidence.

Authors:  Jennifer R Marin; Alyssa M Abo; Alexander C Arroyo; Stephanie J Doniger; Jason W Fischer; Rachel Rempell; Brandi Gary; James F Holmes; David O Kessler; Samuel H F Lam; Marla C Levine; Jason A Levy; Alice Murray; Lorraine Ng; Vicki E Noble; Daniela Ramirez-Schrempp; David C Riley; Turandot Saul; Vaishali Shah; Adam B Sivitz; Ee Tein Tay; David Teng; Lindsey Chaudoin; James W Tsung; Rebecca L Vieira; Yaffa M Vitberg; Resa E Lewiss
Journal:  Crit Ultrasound J       Date:  2016-11-03

3.  Change in optic nerve sheath diameter as a radiological marker of outcome from endoscopic third ventriculostomy in children.

Authors:  Llewellyn C Padayachy; Tracy Kilborn; Henri Carrara; Anthony A Figaji; Graham A Fieggen
Journal:  Childs Nerv Syst       Date:  2015-03-04       Impact factor: 1.475

4.  Effects of prone positioning with neck extension on intracranial pressure according to optic nerve sheath diameter measured using ultrasound in children.

Authors:  Soo-Bin Yoon; Sang-Hwan Ji; Young-Eun Jang; Ji-Hyun Lee; Eun-Hee Kim; Jin-Tae Kim; Hee-Soo Kim
Journal:  Childs Nerv Syst       Date:  2019-12-04       Impact factor: 1.475

5.  The authors reply.

Authors:  Steven L Shein; Michael J Bell
Journal:  Pediatr Crit Care Med       Date:  2016-07       Impact factor: 3.624

Review 6.  Neuromuscular ultrasound of cranial nerves.

Authors:  Eman A Tawfik; Francis O Walker; Michael S Cartwright
Journal:  J Clin Neurol       Date:  2015-04       Impact factor: 3.077

Review 7.  Optic Nerve and Cerebral Edema in the Course of Diabetic Ketoacidosis.

Authors:  Łukasz Szmygel; Wojciech Kosiak; Katarzyna Zorena; Małgorzata Myśliwiec
Journal:  Curr Neuropharmacol       Date:  2016       Impact factor: 7.363

8.  Computed tomography imaging-based normative orbital measurement in Indian population.

Authors:  Vivek Gupta; Anuj Prabhakar; Mukesh Yadav; Niranjan Khandelwal
Journal:  Indian J Ophthalmol       Date:  2019-05       Impact factor: 1.848

9.  Optic Nerve Sheath Diameter Measurement During Diabetic Ketoacidosis: A Pilot Study.

Authors:  Kelly R Bergmann; Donna M Milner; Constantinos Voulgaropoulos; Gretchen J Cutler; Anupam B Kharbanda
Journal:  West J Emerg Med       Date:  2016-07-25

Review 10.  Point-of-care ultrasound of optic nerve sheath diameter to detect intracranial pressure in neurocritically ill children - A narrative review.

Authors:  Jainn-Jim Lin; Aaron E Chen; Elaina E Lin; Shao-Hsuan Hsia; Ming-Chou Chiang; Kuang-Lin Lin
Journal:  Biomed J       Date:  2020-04-23       Impact factor: 4.910

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.