Literature DB >> 23682177

Open reduction and locking plate fixation of displaced proximal humerus fractures.

Chandan Kumar1, Anil Kumar Gupta, Rohit Nath, Javed Ahmad.   

Abstract

BACKGROUND: Treatment of proximal humerus fractures is controversial and various operative modalities have been tried in the literature. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus locking plate.
MATERIALS AND METHODS: 52 patients with displaced proximal humerus fractures treated with proximal humerus locking plate between May 2008 and October 2010 were included in the study. Fractures were classified according to Neer's classification into displaced 2-part, 3-part, and 4-part fractures. Patients were followed for a minimum period of 1 year. 11 patients had less than 1 year of followup and were not considered in the evaluation of final results. Forty one patients were considered for final evaluation. Functional evaluation was done according to the Constant-Murley scoring system. Constant score was compared between 2-part, 3-part, and 4-part fractures at final up and also between young (≤60 yrs) and old (>60 yrs).
RESULTS: 11 patients had 2-part fractures, 22 patients had 3-part fractures, and 19 patients had 4-part fractures. The mean followup period was 15.21 ± 2.59 months. 65.8% (n = 27) patients had good to excellent result, 19.5% (n = 8) had fair, and 14.7% (n = 6) had poor result. Constant scores for 2-part (79.83 ± 6.95) and 3-part fractures (74.22 ± 12.53) were significantly superior to those of 4-part fractures (61.09 ± 14.29) (P value = 0.002 and 0.018, respectively). Difference between 2-part and 3-part fractures was not significant (P value = 0.623). There was no significant difference between younger (≤60) and older patients (>60). Complications encountered in this series were varus malreduction in 17% (n = 7), screw perforation in 10% (n = 4), plate impingement in 12% (n = 5), infection in 2% (n = 1), and nonunion in 2% (n = 1) of cases.
CONCLUSION: Proximal humerus locking plate gives reliable fixation for 2-part and 3-part fractures. Its use in more complicated fracture patterns of 4-part fractures is associated with poor clinical outcome.

Entities:  

Keywords:  Proximal humerus locking plate; proximal humerus fracture; unstable fracture

Year:  2013        PMID: 23682177      PMCID: PMC3654465          DOI: 10.4103/0019-5413.108903

Source DB:  PubMed          Journal:  Indian J Orthop        ISSN: 0019-5413            Impact factor:   1.251


INTRODUCTION

The majority of proximal humerus fractures occur in older age groups as a result of trivial trauma where bones are osteoporotic. Because of osteoporosis and comminution both reduction and fixation are difficult. While for undisplaced fractures, literature strongly suggests nonoperative treatment,1–3 the treatment of displaced fractures is still controversial and challenging. A wide variety of treatment modalities have been used in the past which include transosseous suture fixation, tension band wiring, standard plate and screw fixation, hemireplacement arthroplasty, percutaneous wire, and screw fixation.4–6 But consensus is available on the ideal treatment modality especially of 3-part and 4-part fractures.7–9 Precontoured locking plates work on the principle of angular stability, less disruption of vascularity, and less chances of plate failure.10 Improved fixation by locking plates is attributed to the angular stability of the screws locking in the plate and their three-dimensional distribution in the humeral head. But their use for the treatment of proximal humerus fractures demands an accurate surgical technique, long learning curve to avoid plate impingement, and screw perforation of the articular surface.11–13 Also, like with all locking plates, fracture reduction must be achieved prior to plate application which can be challenging. The aim of the present study was to evaluate functional outcome and complication rate after open reduction and internal fixation of displaced proximal humerus fractures by proximal humerus locking plate.

MATERIALS AND METHODS

This was a prospective study conducted in our institute on a consecutive series of patients for the treatment of displaced (angulation of the articular surface of >45 degrees or displacement of more than 1 cm between the major fracture segments)14 2-part, 3-part, and 4-part proximal humerus fractures from May 2008 to October 2010. After obtaining institutional ethical committee clearance, 57 consecutive patients of displaced proximal humerus fractures (as defined by Neer's criteria) were enrolled in the study. Written informed consent was obtained from all the patients. Open fractures, stable 2-part fractures, isolated tuberosity fractures, bilateral fractures, fractures with ipsilateral significant injuries which could prevent early rehabilitation, head splitting fractures, fracture dislocations, and fractures occurring in children less than 18 years old were excluded from the study. Anteroposterior and axillary views of shoulder were obtained in all patients [Figure 1a and b]. 3-D CT reconstruction was used only in those patients in whom head splitting fracture was suspected. Fractures were classified according to Neer's classification15 into 2-part, 3-part, and 4-part. There were eleven 2-part, twenty two 3-part, and nineteen 4-part fractures. To precisely classify the fractures independent opinion of two orthopaedic surgeons were taken. We used proximal humerus locking plate (Uma surgical, Mumbai) in all patients which is a precontoured plate according to the anatomy of proximal part of humerus. There are five locking screw holes for the head fragment in which the direction of screws are nonparallel. The screw holes in the shaft portion are combi holes and the plate is available in different sizes.
Figure 1

(a) and (b) Preoperative X-ray (anteroposterior and axillary view) of a 3-part proximal humerus fracture

(a) and (b) Preoperative X-ray (anteroposterior and axillary view) of a 3-part proximal humerus fracture All the fractures were operated by senior orthopaedic surgeon (AKG) using a standard deltopectoral approach with the patient in the supine position on a radiolucent table with access for image intensifier to obtain intraoperative anteroposterior and axillary views. Fractures were reduced by manual traction and abduction to neutralize pull of the deltoid muscle. After provisional stabilization of fractures by k-wires, definitive fixation with proximal humerus locking plate was done. Tuberosity fractures were reduced by means of nonabsorbable Ethibond sutures whenever required. If the fracture was reduced plate was applied over lateral aspect of proximal humerus and locking screws were inserted first in the head fragment. Care was taken in placing the plate lateral to the biceps tendon and 5-8 mm distal to upper end of greater tuberosity. In case the shaft was medially displaced first cortical screw (3.5 mm) was inserted in the shaft portion to neutralize pull of pectoralis major muscle. After that, locking screws in the head were inserted. Postoperative x-ray was obtained in all patients [Figure 2]. On immediate postoperative evalutation of X-rays varus malreduction of more than 20 degrees was present in 7 patients and screw perforation was identified in 3 patients.
Figure 2

Postoperative X-rays showing anatomical reduction

Postoperative X-rays showing anatomical reduction Postoperatively arm sling was applied and continued till fracture union. Passive-guarded physiotherapy was started in the first postoperative week and continued till fracture union. Active range of motion exercises and passive stretching exercises were started after fracture union. Patients were followed up at 6 weeks, 3 months, 6 months, 1 year, 1.5 years, and 2 years [Figure 3a and b]. At each visit, functional evaluation was done according to Constant-Murley scoring system [Figure 4a-c].16 The Constant score was graded as poor (0-55 points), fair (56-70), good (71-85), or excellent (86-100). Constant score and its various subcomponents were compared between 2-part, 3-part, and 4-part fractures at the last available followup after 1 year. Scores were also compared between young (≤60 years) and old (>60 years) patients.
Figure 3

(a) and (b) Followup X-ray at 18 months showing union

Figure 4

(a-c) Clinical photographs at 18 month followup showing range of motion

(a) and (b) Followup X-ray at 18 months showing union (a-c) Clinical photographs at 18 month followup showing range of motion The Student t test was used for comparison of scores between young and old patients, while for comparison between three fracture types ANOVA was used. All the statistical calculations were done using SPSS 16 software and the level of significance was set at ≤0.05.

RESULTS

A total of 57 patients of proximal humerus fractures were treated during the above-mentioned period of study. Five patients were excluded from the study by above-mentioned exclusion criteria (two patients had proximal humerus fracture dislocation, two patients had displaced greater tuberosity fracture, and one patient had head splitting fracture). Eleven patients had less than 1 year of followup and were not included in the evaluation of final result. Forty one patients were considered for final evaluation. Patient characteristics are represented in Table 1. 54% patients (n = 22) were less than or equal to 60 years of age and 46% (n = 19) were more than 60 years of age. Patients were operated after an average period of 6.2 days. The average union time was 3 months (range 2-5 months). Clinical evaluation was done according to Constant-Murley score. The overall mean score was 72.34 ± 13.57. 66% (n = 27) patients had good to excellent result, 20% (n = 8) had fair, and 15% (n = 6) had poor result. The mean Constant score for 2-part fractures was 79.83 ± 6.95, of 3-part fractures was 74.22 ± 12.53, and of 4-part fractures was 61.09 ± 14.29. Constant scores for 2-part and 3-part fractures were significantly superior to those of 4-part fractures (P value = 0.002 and 0.018, respectively). Difference between 2-part and 3-part fractures was not significant (P value 0.623). Mean score of patients with age less than or equal to 60 years of age was 73.61 ± 13.51 and in patients with more than 60 years was 70.31 ± 14.26. The difference was not significant (P value 0.564). Differences between pain, activities of daily living, range of motion and strength subcomponents of the Constant-Murley score between 2-part, 3-part and 4-part fractures were also significant [Table 2]. Overall 18 complications occurred in 10 patients [Table 3].
Table 1

Patient demography

Table 2

Comparison of subscores of Constant. Murley score between three fracture types

Table 3

Complications associated with management of proximal humerus fractures with proximal humerus locking plate

Patient demography Comparison of subscores of Constant. Murley score between three fracture types Complications associated with management of proximal humerus fractures with proximal humerus locking plate

DISCUSSION

Treatment of proximal humerus fractures has been controversial. For displaced fractures, traditional treatment with conventional plates and screws has been associated with high rates of unsatisfactory results and complications.17 Locking plates are angular stable plates which has advantage of secure fixation in metaphyseal and osteoporotic bones. There are biomechanical studies which suggest that locking plates resist physiological loads more effectively.1819 There are many clinical studies which indicate that proximal humerus locking plates have good result in proximal humerus fractures.202122 In our study, 66% (n = 27) of the patients had excellent to good outcome. The overall mean Constant score was 72.34 ± 13.57. Aggarwal et al.23 in their study found moderate to excellent outcome in 90% of patients. They also found significantly higher Constant score for younger patients (P value = 0.12). The mean age of the patients in this series was 58.51 years (range 23-81 years) and fracture types were Neer 2-part, 3-part, and 4-part fractures and fracture dislocations. Thyagarajan et al.10 in their study on 30 patients showed an overall average Constant score of 57.5. The mean age in this series was 58 years (range 19-92 years) and fractures were Neer's 2-part, 3-part, and 4-part fractures. Parmaksizoglu et al.24 in their study showed 68.7% excellent to good results. Mean age was 63 years (range 29-82 years) and fractures were Neers, 3-part, and 4-part 31.8% (n=10). Patients have not achieved optimal results. Solberget al.25 in their retrospective study of Neer, 3 and 4-part fractures showed mean Constant score of 64.7 in 4-part fractures. The mean age of the patients in locked plate group was 66.5 ± 8.6 years. In the study of Aggarwal et al.23 the mean Constant score for 4-part fractures was 66 ± 12.61 and was significantly inferior to other types. In our study also the mean Constant score for 4-part fractures was 61.09 ± 14.29 which was significantly inferior compared to 2-part and 3-part fractures (P value = 0.001 and = 0.018, respectively). This result is comparable to the above mentioned studies. In our study, the comparison of subcomponents of Constant score shows a significant difference between 4-part fracture and other two fracture types. Similar findings were reported by Aggarwal et al.23 Varus malreduction has been correlated with poor outcome in many studies. In our study varus malreduction of >20 degrees occurred in 17% of cases (n = 7) [Table 3]. All the patients with varus malreduction had Constant score <70. All but one of the fractures with varus malreduction of >20 degrees united. Four of these cases also had plate impingement in the subacromial area. This implicates varus malreduction as a principal cause of plate impingement in the subacromial area and this error is more common than placing the plate too far superiorly. Screw perforation [Figure 5] occurred in our study in 4 cases. Three out of four screw perforations occurred because of intraoperative errors of screw placement. Similar incidence of screw perforation has been reported in other studies.
Figure 5

Axillary view of shoulder following proximal humeral locking plate fixation showing screw perforation of humeral head

Axillary view of shoulder following proximal humeral locking plate fixation showing screw perforation of humeral head We found no significant difference in outcome between patients of age group less than or more than 60 years of age. Similar findings have been reported by Koukakis et al.20 who reported no significant difference between younger (<65) and older (>65) patients. Moonot et al.22 also reported similar findings. No osteonecrosis occurred in our series. This may be because of smaller number of patients in 4-part fracture group (n = 11). Also, a majority of fractures in 4-part group were in the surgical neck region and hence had low risk of osteonecrosis. The limitation of this study is lack of a control group. A randomized study comparing the result of other treatment modalities will probably serve as a better guideline for treatment of these fractures. We conclude that proximal humerus locking plate fixation for 2-part and 3-part fractures has good functional outcome but its use in 4-part fractures is associated with high complication rate. Use of this implant needs technical expertise and most of the complications occur because of intraoperative technical errors.
  25 in total

1.  Fixation of proximal humerus fractures using the PHILOS plate: early experience.

Authors:  Athanasios Koukakis; Constantinos D Apostolou; Tarun Taneja; Dimitrios S Korres; Alexander Amini
Journal:  Clin Orthop Relat Res       Date:  2006-01       Impact factor: 4.176

2.  A clinical method of functional assessment of the shoulder.

Authors:  C R Constant; A H Murley
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

3.  Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly.

Authors:  John-Erik Bell; Brian C Leung; Kevin F Spratt; Ken J Koval; James D Weinstein; David C Goodman; Anna N A Tosteson
Journal:  J Bone Joint Surg Am       Date:  2011-01-19       Impact factor: 5.284

4.  Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures.

Authors:  David S Thyagarajan; Samarth J Haridas; Denise Jones; Colin Dent; Richard Evans; Rhys Williams
Journal:  Int J Shoulder Surg       Date:  2009-07

5.  Surgical treatment of three and four-part proximal humeral fractures.

Authors:  Brian D Solberg; Charles N Moon; Dennis P Franco; Guy D Paiement
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

6.  Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study.

Authors:  N Südkamp; J Bayer; P Hepp; C Voigt; H Oestern; M Kääb; C Luo; M Plecko; K Wendt; W Köstler; G Konrad
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

7.  Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system.

Authors:  P Moonot; N Ashwood; M Hamlet
Journal:  J Bone Joint Surg Br       Date:  2007-09

8.  Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates.

Authors:  Kenneth A Egol; Crispin C Ong; Michael Walsh; Laith M Jazrawi; Nirmal C Tejwani; Joseph D Zuckerman
Journal:  J Orthop Trauma       Date:  2008-03       Impact factor: 2.512

9.  Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected].

Authors:  Kevin C Owsley; John T Gorczyca
Journal:  J Bone Joint Surg Am       Date:  2008-02       Impact factor: 5.284

10.  Humeral head replacement for acute, four-part proximal humerus fractures.

Authors:  A Green; W L Barnard; R S Limbird
Journal:  J Shoulder Elbow Surg       Date:  2009-02-19       Impact factor: 3.019

View more
  5 in total

1.  [Proximal humerus fractures. Decisive factors for therapy choice, treatment and complications].

Authors:  V Braunstein
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

2.  Titanium mini locking plate with trans-osseous sutures for the treatment of humeral greater tuberosity fracture osteosynthesis versus PHILOS: a retrospective view.

Authors:  Gang Xue; Kapil Chahal; Thou Lim; Siyuan Hu; Shaohua Li; Jie Liu
Journal:  Int Orthop       Date:  2018-03-03       Impact factor: 3.075

3.  Open reduction and Internal Fixation of Displaced Proximal Humerus Fractures with AO Stainless Steel T-Plate.

Authors:  S Hussain; Ma Gul; Sa Dhar
Journal:  Malays Orthop J       Date:  2014-03

Review 4.  Complications Associated with Locking Plate of Proximal Humerus Fractures.

Authors:  Venkat Kavuri; Blake Bowden; Neil Kumar; Doug Cerynik
Journal:  Indian J Orthop       Date:  2018 Mar-Apr       Impact factor: 1.251

5.  Assessment of Surgical Outcome in Three- and Four-Part Proximal Humerus Fracture Treated With Proximal Humerus Internal Locking System (PHILOS) Plate Versus Neer's Prosthesis in Elderly Patients.

Authors:  Sagar Gurnani; Tushar Pisal; Mukesh O Phalak; Tushar Chaudhari; Shivam Patel; Parth Yadav; S K Mizanur
Journal:  Cureus       Date:  2022-02-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.