Literature DB >> 29500554

Titanium mini locking plate with trans-osseous sutures for the treatment of humeral greater tuberosity fracture osteosynthesis versus PHILOS: a retrospective view.

Gang Xue1, Kapil Chahal1, Thou Lim2, Siyuan Hu1, Shaohua Li3, Jie Liu4.   

Abstract

PURPOSE: Greater tuberosity fractures (GTFs) account for 17 to 21% of proximal humerus fractures, most of these fractures are treated conservatively, but treatment for displaced fractures is still controversial. The aim of this study is to compare intra-operative clinical conditions and post-operative outcomes when displaced GTFs are treated with either proximal humeral internal locking system (PHILOS) or mini locking plate with trans-osseous sutures.
METHODS: This is a retrospective study conducted in Shanghai Tenth People's Hospital. A total of 60 patients (22 males and 38 females) with displaced humeral GTF between May 2013 and March 2017 were included, of whom 43 underwent PHILOS implant treatment and 17 underwent titanium mini plate implant with trans-osseous suture treatment. Intra-operative (incision size, intra-operative blood loss, operative duration) and postoperative (Constant-Murley score (CMS) and implant cost) variables were recorded for the comparison.
RESULTS: Mini locking plate with trans-osseous sutures shows better results. Operative duration (PHILOS mean 77.0 minutes vs mean 63.7 minutes, p value < 0.05), blood loss during surgery (PHILOS mean 111.5 vs 66.5 ml, p value < 0.05), incision size (PHILOS mean 7.2 vs 4.6 cm, p value < 0.05), CMS (PHILOS mean 81.0 vs 87.3, p value < 0.05), and implant costs (PHILOS mean 26,192.6 renminbi (RMB) vs mean 21,358.8 RMB, p value < 0.05). On the other hand, 9.30% of impingement in the PHILOS group was observed to have no complications compared to the mini locking plate group.
CONCLUSIONS: Mini locking plate with trans-osseous sutures shows better efficacy in reducing the incision size, operative duration, intraoperative blood loss, and implant cost and in improving CMS. No complication was found with its use. Our data can provide rationale and inform sample- size calculations for such studies. Larger, control studies are needed for better understanding.

Entities:  

Keywords:  Fracture; Gang Xue and Kapil Chahal contributed equally to this study.; Greater tuberosity fracture; Humerus; Mini locking plate; PHILOS; Trans-osseous sutures

Mesh:

Substances:

Year:  2018        PMID: 29500554     DOI: 10.1007/s00264-018-3823-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  28 in total

1.  Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures--results of an international multicentre study.

Authors:  Gerhard Konrad; Anja Hirschmüller; Laurent Audige; Simon Lambert; Ralf Hertel; Norbert P Südkamp
Journal:  Int Orthop       Date:  2011-11-30       Impact factor: 3.075

2.  Shoulder hemiarthroplasty for the treatment of three and four part fractures of the proximal humerus using Comprehensive® Fracture stem.

Authors:  Nasir Shah; Hafiz J Iqbal; Steven Brookes-Fazakerley; Chris Sinopidis
Journal:  Int Orthop       Date:  2010-07-14       Impact factor: 3.075

3.  Trabecular metal™ shoulder prosthesis in the treatment of complex proximal humeral fractures.

Authors:  Fenglong Li; Chunyan Jiang
Journal:  Int Orthop       Date:  2013-08-21       Impact factor: 3.075

4.  The amount of humeral head impaction of proximal humeral fractures fixed with the Humerusblock device.

Authors:  Stefano Carbone; Philipp Moroder; Valerio Arceri; Roberto Postacchini; Stefano Gumina
Journal:  Int Orthop       Date:  2014-04-04       Impact factor: 3.075

5.  Minimally invasive percutaneous osteosynthesis for proximal humeral shaft fractures with the PHILOS through the deltopectoral approach.

Authors:  Zu-Bin Zhou; You-Shui Gao; Ming-Jie Tang; Yu-Qiang Sun; Chang-Qing Zhang
Journal:  Int Orthop       Date:  2012-09-07       Impact factor: 3.075

Review 6.  Treatment of proximal humerus fractures in the elderly: a systemic review of 409 patients.

Authors:  Antti P Launonen; Vesa Lepola; Tapio Flinkkilä; Minna Laitinen; Mika Paavola; Antti Malmivaara
Journal:  Acta Orthop       Date:  2015-01-09       Impact factor: 3.717

7.  Mid-term results of a less-invasive locking plate fixation method for proximal humeral fractures: a prospective observational study.

Authors:  Benjamin Bockmann; Benjamin Buecking; Daniel Franz; Ralph Zettl; Steffen Ruchholtz; Juliane Mohr
Journal:  BMC Musculoskelet Disord       Date:  2015-07-04       Impact factor: 2.362

8.  Reverse shoulder arthroplasty for proximal humerus fracture using a dedicated stem: radiological outcomes at a minimum 2 years of follow-up-case series.

Authors:  Raffaele Garofalo; Brody Flanagin; Alessandro Castagna; Eddie Y Lo; Sumant G Krishnan
Journal:  J Orthop Surg Res       Date:  2015-08-22       Impact factor: 2.359

9.  Comparison between minimally invasive, percutaneous osteosynthesis and locking plate osteosynthesis in 3-and 4-part proximal humerus fractures.

Authors:  Reinhold Ortmaier; Verena Filzmaier; Wolfgang Hitzl; Robert Bogner; Thomas Neubauer; Herbert Resch; Alexander Auffarth
Journal:  BMC Musculoskelet Disord       Date:  2015-10-14       Impact factor: 2.362

10.  Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year.

Authors:  Jan-Magnus Björkenheim; Jarkko Pajarinen; Vesa Savolainen
Journal:  Acta Orthop Scand       Date:  2004-12
View more
  2 in total

Review 1.  Surgical fixation of isolated greater tuberosity fractures of the humerus- systematic review and meta-analysis.

Authors:  Sachin Kumar; Arya Mishra; Hemant Singh; David Clark; Marius Espag; Amol Tambe
Journal:  J Clin Orthop Trauma       Date:  2021-10-27

2.  Effect of Joint Use of External Minifixator and Titanium Lockplate on Total Active Motion Range and Hand Function Recovery in Comminuted Metacarpal and Phalanx Fracture Patients.

Authors:  Yao Li; Hongwei Zhang
Journal:  J Healthc Eng       Date:  2022-01-25       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.