Betabox: a beta particle imaging system based on a position sensitive avalanche photodiode.

A A Dooraghi1, N T Vu, R W Silverman, R Farrell, K S Shah, J Wang, J R Heath, A F Chatziioannou.   

Abstract

A beta camera has been developed that allows planar imaging of the spatial and temporal distribution of beta particles using a 14 × 14 mm(2) position sensitive avalanche photodiode (PSAPD). This camera system, which we call Betabox, can be directly coupled to microfluidic chips designed for cell incubation or other biological applications. Betabox allows for imaging the cellular uptake of molecular imaging probes labeled with charged particle emitters such as (18)F inside these chips. In this work, we investigate the quantitative imaging capabilities of Betabox for (18)F beta particles, in terms of background rate, efficiency, spatial resolution, and count rate. Measurements of background and spatial resolution are considered both at room temperature (21 °C ± 1 °C) and at an elevated operating temperature (37 °C ± 1 °C), as is often required for biological assays. The background rate measured with a 4 keV energy cutoff is below 2 cph mm(-2) at both 21 and 37 °C. The absolute efficiency of Betabox for the detection of (18)F positron sources in contact with a PSAPD with the surface passivated from ambient light and damage is 46% ± 1%. The lower detection limit is estimated using the Rose Criterion to be 0.2 cps mm(-2) for 1 min acquisitions and a 62 × 62 µm(2) pixel size. The upper detection limit is approximately 21 000 cps. The spatial resolution at both 21 and 37 °C ranges from 0.4 mm FWHM at the center of the field of view (FOV), and degrades to 1 mm at a distance of 5 mm away from center yielding a useful FOV of approximately 10 × 10 mm(2). We also investigate the effects on spatial resolution and sensitivity that result from the use of a polymer based microfluidic chip. For these studies we place varying layers of low-density polyethylene (LDPE) between the detector and the source and find that the spatial resolution degrades by ∼180 µm for every 100 µm of LDPE film. Sensitivity is reduced by half with the inclusion of ∼200 µm of additional LDPE film. Lastly, we demonstrate the practical utilization of Betabox, with an imaging test of its linearity, when coupled to a polydimethylsiloxane microfluidic chip designed for cell based assays.

Entities:  

Mesh:

Year:  2013        PMID: 23656911      PMCID: PMC3706465          DOI: 10.1088/0031-9155/58/11/3739

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Beta camera for static and dynamic imaging of charged-particle emitting radionuclides in biologic samples.

Authors:  K Ljunggren; S E Strand
Journal:  J Nucl Med       Date:  1990-12       Impact factor: 10.057

2.  Production of radioactive quality assurance phantoms using a standard inkjet printer.

Authors:  J A van Staden; H du Raan; M G Lötter; A van Aswegen; C P Herbst
Journal:  Phys Med Biol       Date:  2007-07-03       Impact factor: 3.609

3.  A New Positioning Algorithm for Position-Sensitive Avalanche Photodiodes.

Authors:  Jin Zhang; Peter D Olcott; Craig S Levin
Journal:  IEEE Trans Nucl Sci       Date:  2007-06-01       Impact factor: 1.679

Review 4.  Applications of autoradiography in neurobiological research.

Authors:  C Pilgrim; W E Stumpf
Journal:  J Histochem Cytochem       Date:  1987-08       Impact factor: 2.479

5.  A new high resolution radioimager for the quantitative analysis of radiolabelled molecules in tissue section.

Authors:  P Laniece; Y Charon; A Cardona; L Pinot; S Maitrejean; R Mastrippolito; B Sandkamp; L Valentin
Journal:  J Neurosci Methods       Date:  1998-12-31       Impact factor: 2.390

6.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

Review 7.  Use of PET for monitoring cancer therapy and for predicting outcome.

Authors:  Wolfgang A Weber
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

8.  A beta-camera integrated with a microfluidic chip for radioassays based on real-time imaging of glycolysis in small cell populations.

Authors:  Nam T Vu; Zeta T F Yu; Begonya Comin-Anduix; Jonas N Søndergaard; Robert W Silverman; Canny Y N Chang; Antoni Ribas; Hsian-Rong Tseng; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2011-05       Impact factor: 10.057

9.  Temperature dependent operation of PSAPD-based compact gamma camera for SPECT imaging.

Authors:  Sangtaek Kim; Mickel McClish; Fares Alhassen; Youngho Seo; Kanai S Shah; Robert G Gould
Journal:  IEEE Trans Nucl Sci       Date:  2011-10-10       Impact factor: 1.679

10.  Positron detection for the intraoperative localisation of cancer deposits.

Authors:  Morand Piert; Maria Burian; Günther Meisetschläger; Hubert J Stein; Sibylle Ziegler; Jörg Nährig; Maria Picchio; Andreas Buck; Joerg R Siewert; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-04-12       Impact factor: 9.236

View more
  7 in total

1.  Integration of High-Resolution Radiation Detector for Hybrid Microchip Electrophoresis.

Authors:  Jason Jones; Noel S Ha; Alec G Barajas; Arion F Chatziioannou; R Michael van Dam
Journal:  Anal Chem       Date:  2020-02-07       Impact factor: 6.986

2.  Performance evaluation of 18 F radioluminescence microscopy using computational simulation.

Authors:  Qian Wang; Debanti Sengupta; Tae Jin Kim; Guillem Pratx
Journal:  Med Phys       Date:  2017-04-17       Impact factor: 4.071

3.  Optimization of microfluidic PET tracer synthesis with Cerenkov imaging.

Authors:  Alex A Dooraghi; Pei Y Keng; Supin Chen; Muhammad R Javed; Chang-Jin C J Kim; Arion F Chatziioannou; R Michael van Dam
Journal:  Analyst       Date:  2013-10-07       Impact factor: 4.616

4.  Quantitative assessments of glycolysis from single cells.

Authors:  Young Shik Shin; Jungwoo Kim; Dazy Johnson; Alex A Dooraghi; Wilson X Mai; Lisa Ta; Arion F Chatziioannou; Michael E Phelps; David A Nathanson; James R Heath
Journal:  Technology (Singap World Sci)       Date:  2015-06-25

5.  Fast metabolic response to drug intervention through analysis on a miniaturized, highly integrated molecular imaging system.

Authors:  Jun Wang; Kiwook Hwang; Daniel Braas; Alex Dooraghi; David Nathanson; Dean O Campbell; Yuchao Gu; Troy Sandberg; Paul Mischel; Caius Radu; Arion F Chatziioannou; Michael E Phelps; Heather Christofk; James R Heath
Journal:  J Nucl Med       Date:  2013-08-26       Impact factor: 10.057

Review 6.  Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals.

Authors:  Noel S Ha; Saman Sadeghi; R Michael van Dam
Journal:  Micromachines (Basel)       Date:  2017-11-21       Impact factor: 2.891

7.  Single-Cell Phosphoproteomics Resolves Adaptive Signaling Dynamics and Informs Targeted Combination Therapy in Glioblastoma.

Authors:  Wei Wei; Young Shik Shin; Min Xue; Tomoo Matsutani; Kenta Masui; Huijun Yang; Shiro Ikegami; Yuchao Gu; Ken Herrmann; Dazy Johnson; Xiangming Ding; Kiwook Hwang; Jungwoo Kim; Jian Zhou; Yapeng Su; Xinmin Li; Bruno Bonetti; Rajesh Chopra; C David James; Webster K Cavenee; Timothy F Cloughesy; Paul S Mischel; James R Heath; Beatrice Gini
Journal:  Cancer Cell       Date:  2016-04-11       Impact factor: 31.743

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.