Literature DB >> 23649181

Magnetostimulation limits in magnetic particle imaging.

Emine U Saritas1, Patrick W Goodwill, George Z Zhang, Steven M Conolly.   

Abstract

For magnetic particle imaging (MPI), specific absorption rate (SAR) and more critically magnetostimulation (i.e., dB/dt) safety limits will determine the optimal scan parameters, such as the drive field strength and frequency. These parameters will impact the scanning speed, field-of-view (FOV) and signal-to-noise ratio in MPI. Understanding the potential safety hazards of the drive field is critical for scaling MPI for human use. In this work, we demonstrate that magnetostimulation is the primary magnetic safety consideration in MPI, and we describe the first human-subject magnetostimulation threshold experiments for MPI using homogeneous coils. Our experiments, performed on the arm and leg, indicate that magnetostimulation thresholds monotonically decrease with increasing frequency. Additionally, we show for the first time that a strong inverse correlation exists between the threshold and the body part size. The chronaxie time, on the other hand, did not vary with body part size. We conclude with an estimation of the magnetostimulation thresholds for a full-body MPI scanner: a mean asymptotic threshold of 14.3 mT-pp (peak-to-peak) with a mean chronaxie time of 289 μs, which correspond to a magnetostimulation threshold of about 15 mT-pp for frequencies between 25 and 50 kHz. These findings will have a great impact on the optimization of MPI parameters, especially in determining the number of partial FOVs required to cover a region of interest.

Entities:  

Mesh:

Year:  2013        PMID: 23649181     DOI: 10.1109/TMI.2013.2260764

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  36 in total

1.  Low drive field amplitude for improved image resolution in magnetic particle imaging.

Authors:  Laura R Croft; Patrick W Goodwill; Justin J Konkle; Hamed Arami; Daniel A Price; Ada X Li; Emine U Saritas; Steven M Conolly
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

2.  Effects of pulse duration on magnetostimulation thresholds.

Authors:  Emine U Saritas; Patrick W Goodwill; Steven M Conolly
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

3.  Slew-rate dependence of tracer magnetization response in magnetic particle imaging.

Authors:  Saqlain A Shah; R M Ferguson; K M Krishnan
Journal:  J Appl Phys       Date:  2014-10-29       Impact factor: 2.546

4.  Moving table magnetic particle imaging: a stepwise approach preserving high spatio-temporal resolution.

Authors:  Patryk Szwargulski; Nadine Gdaniec; Matthias Graeser; Martin Möddel; Florian Griese; Kannan M Krishnan; Thorsten M Buzug; Tobias Knopp
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

5.  Pulsed Excitation in Magnetic Particle Imaging.

Authors:  Zhi Wei Tay; Daniel Hensley; Jie Ma; Prashant Chandrasekharan; Bo Zheng; Patrick Goodwill; Steven Conolly
Journal:  IEEE Trans Med Imaging       Date:  2019-02-11       Impact factor: 10.048

6.  Magnetic Particle Imaging-Guided Heating in Vivo Using Gradient Fields for Arbitrary Localization of Magnetic Hyperthermia Therapy.

Authors:  Zhi Wei Tay; Prashant Chandrasekharan; Andreina Chiu-Lam; Daniel W Hensley; Rohan Dhavalikar; Xinyi Y Zhou; Elaine Y Yu; Patrick W Goodwill; Bo Zheng; Carlos Rinaldi; Steven M Conolly
Journal:  ACS Nano       Date:  2018-03-28       Impact factor: 15.881

7.  The Relaxation Wall: Experimental Limits to Improving MPI Spatial Resolution by Increasing Nanoparticle Core size.

Authors:  Zhi Wei Tay; Daniel W Hensley; Erika C Vreeland; Bo Zheng; Steven M Conolly
Journal:  Biomed Phys Eng Express       Date:  2017-04-27

8.  Sensitivity analysis of neurodynamic and electromagnetic simulation parameters for robust prediction of peripheral nerve stimulation.

Authors:  Valerie Klein; Mathias Davids; Lawrence L Wald; Lothar R Schad; Bastien Guérin
Journal:  Phys Med Biol       Date:  2018-12-19       Impact factor: 3.609

9.  Variation of Magnetic Particle Imaging Tracer Performance With Amplitude and Frequency of the Applied Magnetic Field.

Authors:  Asahi Tomitaka; Richard Matthew Ferguson; Amit P Khandhar; Scott J Kemp; Satoshi Ota; Kosuke Nakamura; Yasushi Takemura; Kannan M Krishnan
Journal:  IEEE Trans Magn       Date:  2015-03-25       Impact factor: 1.700

10.  Drive-field Frequency Dependent MPI Performance of Single-Core Magnetite Nanoparticle Tracers.

Authors:  C Kuhlmann; A P Khandhar; R M Ferguson; S Kemp; T Wawrzik; M Schilling; K M Krishnan; F Ludwig
Journal:  IEEE Trans Magn       Date:  2015-02       Impact factor: 1.700

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.