Jonathan M Vigdorchik1, Amanda O Esquivel, Xin Jin, King H Yang, Rahul Vaidya. 1. Orthopaedic Surgery, Detroit Medical Center, 4D4 University Health Center, Detroit Receiving Hospital, Wayne State University, 4201 St. Antoine Blvd., Detroit, MI 48201, USA. JVigdorchik@gmail.com
Abstract
PURPOSE: The purpose of this study was to evaluate the biomechanical stability and compressive forces across the sacroiliac (SI) joint of an anterior internal fixator compared to the femoral distractor and external fixator for vertically unstable pelvic fractures. METHODS: Five composite pelvises with a simulated APC type III injury fixed with a femoral distractor, external fixator, or anterior internal fixator were tested. A pressure-sensitive film (Tekscan) was placed in the disrupted SI joint recording the magnitude of force. Then, in a single-leg stance model (Instron machine), a load was applied through the sacrum. We recorded displacement at the pubic symphysis and SI joint using high-speed video. Peak load and displacement were measured, and axial stiffness was calculated. Values were compared using a Student's t-test (p < 0.05). RESULTS: The SI joint was compressed significantly (p < 0.001) more using the anterior internal fixator (18.9 N) and femoral distractor (18.6 N) than the two-pin external fixator (2.5 N). There was no significant difference between the anterior internal fixator and the femoral distractor in displacement at the SI joint. The pubic symphysis displaced less with the femoral distractor than the anterior internal fixator (5.5 mm vs. 4.1 mm; p < 0.05). CONCLUSIONS: The anterior pedicle screw internal fixator allows for indirect compression across the sacroiliac joint that is superior to two-pin external fixation and comparable to the femoral distractor. The anterior internal fixator may be an option for temporary anterior pelvic fixation in situations where external fixation or the femoral distractor have otherwise been used.
PURPOSE: The purpose of this study was to evaluate the biomechanical stability and compressive forces across the sacroiliac (SI) joint of an anterior internal fixator compared to the femoral distractor and external fixator for vertically unstable pelvic fractures. METHODS: Five composite pelvises with a simulated APC type III injury fixed with a femoral distractor, external fixator, or anterior internal fixator were tested. A pressure-sensitive film (Tekscan) was placed in the disrupted SI joint recording the magnitude of force. Then, in a single-leg stance model (Instron machine), a load was applied through the sacrum. We recorded displacement at the pubic symphysis and SI joint using high-speed video. Peak load and displacement were measured, and axial stiffness was calculated. Values were compared using a Student's t-test (p < 0.05). RESULTS: The SI joint was compressed significantly (p < 0.001) more using the anterior internal fixator (18.9 N) and femoral distractor (18.6 N) than the two-pin external fixator (2.5 N). There was no significant difference between the anterior internal fixator and the femoral distractor in displacement at the SI joint. The pubic symphysis displaced less with the femoral distractor than the anterior internal fixator (5.5 mm vs. 4.1 mm; p < 0.05). CONCLUSIONS: The anterior pedicle screw internal fixator allows for indirect compression across the sacroiliac joint that is superior to two-pin external fixation and comparable to the femoral distractor. The anterior internal fixator may be an option for temporary anterior pelvic fixation in situations where external fixation or the femoral distractor have otherwise been used.
Authors: Michael J Gardner; Daniel Kendoff; Sven Ostermeier; Musa Citak; Tobias Hüfner; Christian Krettek; Sean E Nork Journal: J Orthop Trauma Date: 2007-08 Impact factor: 2.512
Authors: Rahul Vaidya; Erik N Kubiak; Patrick F Bergin; Derek G Dombroski; Ren J Critchlow; Anil Sethi; Adam J Starr Journal: Clin Orthop Relat Res Date: 2012-08 Impact factor: 4.176
Authors: G Osterhoff; S Tiziani; C Hafner; S J Ferguson; H-P Simmen; C M L Werner Journal: Eur J Trauma Emerg Surg Date: 2015-04-17 Impact factor: 3.693
Authors: Rahul Vaidya; Adam Jonathan Martin; Matthew Roth; Kerellos Nasr; Petra Gheraibeh; Frederick Tonnos Journal: Int Orthop Date: 2017-01-11 Impact factor: 3.075
Authors: Miguel Pishnamaz; Thomas Dienstknecht; Barbara Hoppe; Christina Garving; Henning Lange; Frank Hildebrand; Philipp Kobbe; Hans-Christoph Pape Journal: Int Orthop Date: 2015-08-11 Impact factor: 3.075
Authors: Martin C Jordan; Veronika Jäckle; Sebastian Scheidt; Fabian Gilbert; Stefanie Hölscher-Doht; Süleyman Ergün; Rainer H Meffert; Timo M Heintel Journal: Sci Rep Date: 2021-06-29 Impact factor: 4.379