Literature DB >> 18829031

Structural properties of fourth-generation composite femurs and tibias.

Anneliese D Heiner1.   

Abstract

The purpose of this study was to measure the structural properties of the latest design (fourth-generation) of composite femurs and tibias from Pacific Research Laboratories, Inc. Fourth-generation composite bones have the same geometries as the third-generation bones, but the cortical bone analogue material was changed to one with increased fracture and fatigue resistance, tensile and compressive properties, thermal stability, and moisture resistance. The stiffnesses of the femurs and tibias were tested under bending, axial, and torsional loading, and the longitudinal strain distribution along the proximal-medial diaphysis of the femur was also determined. The fourth-generation composite bones had average stiffnesses and strains that were for the most part closer to corresponding values measured for natural bones, than was the case for third-generation composite bones; all measurements were taken by the same investigator in separate studies using identical methodology. For the stiffness tests, variability between the specimens was less than 10% for all cases, and setup variability was less than 6%.

Entities:  

Mesh:

Year:  2008        PMID: 18829031     DOI: 10.1016/j.jbiomech.2008.08.013

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  63 in total

1.  Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? A biomechanical study.

Authors:  Gaston Camino Willhuber; Ivan Zderic; Florian Gras; Dieter Wahl; Carlos Sancineto; Jorge Barla; Markus Windolf; Robert Geoff Richards; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2015-10-05       Impact factor: 3.075

2.  Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

Authors:  Nikhil R Oak; John R Lien; Alexander Brunfeldt; Jeffrey N Lawton
Journal:  Hand (N Y)       Date:  2017-03-23

3.  Inversion of the acetabular labrum causes increased localized contact pressure on the femoral head: a biomechanical study.

Authors:  Xipeng Wang; Kiyokazu Fukui; Ayumi Kaneuji; Kenichi Hirosaki; Hiroyasu Miyakawa; Norio Kawahara
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

4.  A new angle stable nailing concept for the treatment of distal tibia fractures.

Authors:  Sebastian Kuhn; Philipp Appelmann; Philip Pairon; Dorothea Mehler; Frank Hartmann; Pol M Rommens
Journal:  Int Orthop       Date:  2014-01-09       Impact factor: 3.075

5.  Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty.

Authors:  A Completo; F Fonseca; C Relvas; A Ramos; J A Simões
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-01       Impact factor: 4.342

6.  Comparative assessment of different reconstructive techniques of distal femur in revision total knee arthroplasty.

Authors:  A Completo; F Fonseca; A Ramos; J Simões
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-30       Impact factor: 4.342

7.  Vertically Oriented Femoral Neck Fractures: A Biomechanical Comparison of 3 Fixation Constructs.

Authors:  Joey P Johnson; Todd R Borenstein; Gregory R Waryasz; Stephen A Klinge; Philip K McClure; Alison B Chambers; Roman A Hayda; Christopher T Born
Journal:  J Orthop Trauma       Date:  2017-07       Impact factor: 2.512

8.  Pullout Strength After Multiple Reinsertions in Radial Bone Fixation.

Authors:  Alfonso Mejia; Giovanni Solitro; Elena Gonzalez; Amit Parekh; Mark Gonzalez; Farid Amirouche
Journal:  Hand (N Y)       Date:  2018-09-06

9.  A Biomechanical Comparison Of Pin Configurations Used For Percutaneous Pinning Of Distal Tibia Fractures In Children.

Authors:  Justin Brantley; Aditi Majumdar; J Taylor Jobe; Antony Kallur; Christina Salas
Journal:  Iowa Orthop J       Date:  2016

10.  Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.

Authors:  Lars Eden; Stefanie Doht; Sönke P Frey; Dirk Ziegler; Jan Stoyhe; Kai Fehske; Torsten Blunk; Rainer H Meffert
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.