Literature DB >> 17762472

Sacroiliac joint compression using an anterior pelvic compressor: a mechanical study in synthetic bone.

Michael J Gardner1, Daniel Kendoff, Sven Ostermeier, Musa Citak, Tobias Hüfner, Christian Krettek, Sean E Nork.   

Abstract

OBJECTIVES: Pelvic external fixation pins placed in the supraacetabular region, directed posteriorly, and mounted with a femoral distractor as a compressor may impart compression forces across the sacroiliac joint. This would be useful for indirect reduction and stabilization of the posterior pelvis. The purpose of this study was to determine the forces achieved by this construct compared with other forms of fixation.
DESIGN: Mechanical study.
SETTING: University laboratory. PATIENTS: Synthetic pelvis models. INTERVENTION: A complete symphyseal and unilateral sacroiliac joint disruption was created in 6 synthetic pelves. Five different fixation constructs were applied, and a pressure-sensitive film (TekScan) was fixed in the sacroiliac joint. Each construct was compressed in a standardized fashion. MAIN OUTCOME MEASUREMENTS: After maximal compression of each trial, the magnitude and regional distribution of the force was recorded.
RESULTS: Standard 2-bar external fixation did not allow for any compression across the sacroiliac joint in any specimen. The pelvic compressor delivered 86.3 N (SD, 12.1 N) of force across the sacroiliac joint when the pins were inserted half way, and 85.8 N (SD, 11.0 N) with full pin insertion. Iliosacral screws led to 145 N of compression on average (SD, 69.9 N), but this was not statistically different from the pelvic compressor groups. A C-clamp generated compression of 206 N (SD, 31.9 N), which was significantly greater than both the pelvic compressor groups (P < 0.005).
CONCLUSIONS: A simple modification of pelvic external fixation, placing a femoral distractor as a compressor on supraacetabular pins, allows for indirect medial translation of the innominate bone and compression across the sacroiliac joint. The force achieved is less than with a C-clamp, but it is safer, involves techniques familiar to most surgeons, and may be useful in the acute management of unstable pelvic fractures.

Entities:  

Mesh:

Year:  2007        PMID: 17762472     DOI: 10.1097/BOT.0b013e318126bb8e

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  13 in total

1.  13-Year experience in external fixation of the pelvis: complications, reduction and removal.

Authors:  P M Mitchell; C M Corrigan; N A Patel; A J Silverberg; S E Greenberg; R V Thakore; W T Obremskey; J M Ehrenfeld; J M Evans; M K Sethi
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-24       Impact factor: 3.693

2.  Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Rahul Vaidya
Journal:  Int Orthop       Date:  2013-05-04       Impact factor: 3.075

3.  Emergency pelvic stabilization in patients with pelvic posttraumatic instability.

Authors:  Dan V Poenaru; Mircea Popescu; Bogdan Anglitoiu; Iulian Popa; Diana Andrei; Florin Birsasteanu
Journal:  Int Orthop       Date:  2015-03-14       Impact factor: 3.075

4.  Can a modified anterior external fixator provide posterior compression of AP compression type III pelvic injuries?

Authors:  Richard Martin Sellei; Peter Schandelmaier; Philipp Kobbe; Matthias Knobe; Hans-Christoph Pape
Journal:  Clin Orthop Relat Res       Date:  2013-09       Impact factor: 4.176

5.  How effective are different models of pelvic binders: results of a study using a Pelvic Emergency Simulator.

Authors:  Uwe Schweigkofler; Dennis Wincheringer; Jörg Holstein; Tobias Fritz; Reinhard Hoffmann; Tim Pohlemann; Steven C Herath
Journal:  Eur J Trauma Emerg Surg       Date:  2020-05-26       Impact factor: 3.693

6.  Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Ndidi A Onwudiwe; Rahul Vaidya
Journal:  J Orthop Surg Res       Date:  2012-09-27       Impact factor: 2.359

7.  Mechanical testing of a device for subcutaneous internal anterior pelvic ring fixation versus external pelvic ring fixation.

Authors:  Georg Osterhoff; Simon Tiziani; Stephen J Ferguson; Gregor Spreiter; Max J Scheyerer; Gian-Leza Spinas; Guido A Wanner; Hans-Peter Simmen; Clément M L Werner
Journal:  BMC Musculoskelet Disord       Date:  2014-03-31       Impact factor: 2.362

8.  Biomechanical Comparison of Five Fixation Techniques for Unstable Fragility Fractures of the Pelvic Ring.

Authors:  Moritz F Lodde; J Christoph Katthagen; Clemens O Schopper; Ivan Zderic; Geoff Richards; Boyko Gueorguiev; Michael J Raschke; René Hartensuer
Journal:  J Clin Med       Date:  2021-05-26       Impact factor: 4.241

9.  The role of anterior supra-acetabular external fixator as definitive treatment for anterior ring fixation in unstable pelvic fractures.

Authors:  Cristián Barrientos-Mendoza; Julián Brañes; Rodrigo Wulf; Alex Kremer; Maximiliano Barahona; Sebastián León
Journal:  Eur J Trauma Emerg Surg       Date:  2021-06-07       Impact factor: 2.374

10.  Compression and contact area of anterior strut grafts in spinal instrumentation: a biomechanical study.

Authors:  Antonius Pizanis; Jörg H Holstein; Felix Vossen; Markus Burkhardt; Tim Pohlemann
Journal:  BMC Musculoskelet Disord       Date:  2013-08-26       Impact factor: 2.362

View more