PURPOSE: Validation of a novel minimally invasive, image-guided approach to implant electrodes from three FDA-approved manufacturers-Medel, Cochlear, and Advanced Bionics-in the cochlea via a linear tunnel from the lateral cranium through the facial recess to the cochlea. METHODS: Custom microstereotactic frames that mount on bone-implanted fiducial markers and constrain the drill along the desired path were utilized on seven cadaver specimens. A linear tunnel was drilled from the lateral skull to the cochlea followed by a marginal, round window cochleostomy and insertion of the electrode array into the cochlea through the drilled tunnel. Post-insertion CT scan and histological analysis were used to analyze the results. RESULTS: All specimens ([Formula: see text]) were successfully implanted without visible injury to the facial nerve. The Medel electrodes ([Formula: see text]) had minimal intracochlear trauma with 8, 8, and 10 (out of 12) electrodes intracochlear. The Cochlear lateral wall electrodes (straight research arrays) ([Formula: see text]) had minimal trauma with 20 and 21 of 22 electrodes intracochlear. The Advanced Bionics electrodes ([Formula: see text]) were inserted using their insertion tool; one had minimal insertion trauma and 14 of 16 electrodes intracochlear, while the other had violation of the basilar membrane just deep to the cochleostomy following which it remained in scala vestibuli with 13 of 16 electrodes intracochlear. CONCLUSIONS: Minimally invasive, image-guided cochlear implantation is possible using electrodes from the three FDA-approved manufacturers. Lateral wall electrodes were associated with less intracochlear trauma suggesting that they may be better suited for this surgical technique.
PURPOSE: Validation of a novel minimally invasive, image-guided approach to implant electrodes from three FDA-approved manufacturers-Medel, Cochlear, and Advanced Bionics-in the cochlea via a linear tunnel from the lateral cranium through the facial recess to the cochlea. METHODS: Custom microstereotactic frames that mount on bone-implanted fiducial markers and constrain the drill along the desired path were utilized on seven cadaver specimens. A linear tunnel was drilled from the lateral skull to the cochlea followed by a marginal, round window cochleostomy and insertion of the electrode array into the cochlea through the drilled tunnel. Post-insertion CT scan and histological analysis were used to analyze the results. RESULTS: All specimens ([Formula: see text]) were successfully implanted without visible injury to the facial nerve. The Medel electrodes ([Formula: see text]) had minimal intracochlear trauma with 8, 8, and 10 (out of 12) electrodes intracochlear. The Cochlear lateral wall electrodes (straight research arrays) ([Formula: see text]) had minimal trauma with 20 and 21 of 22 electrodes intracochlear. The Advanced Bionics electrodes ([Formula: see text]) were inserted using their insertion tool; one had minimal insertion trauma and 14 of 16 electrodes intracochlear, while the other had violation of the basilar membrane just deep to the cochleostomy following which it remained in scala vestibuli with 13 of 16 electrodes intracochlear. CONCLUSIONS: Minimally invasive, image-guided cochlear implantation is possible using electrodes from the three FDA-approved manufacturers. Lateral wall electrodes were associated with less intracochlear trauma suggesting that they may be better suited for this surgical technique.
Authors: Ramya Balachandran; Jason E Mitchell; Grégoire Blachon; Jack H Noble; Benoit M Dawant; J Michael Fitzpatrick; Robert F Labadie Journal: Otolaryngol Head Neck Surg Date: 2010-03 Impact factor: 3.497
Authors: Elias D Stratigouleas; Brian P Perry; Susan Marenda King; Charles A Syms Journal: Otolaryngol Head Neck Surg Date: 2006-09 Impact factor: 3.497
Authors: Robert Frederick Labadie; Jack H Noble; Benoit M Dawant; Ramya Balachandran; Omid Majdani; J Michael Fitzpatrick Journal: Laryngoscope Date: 2008-06 Impact factor: 3.325
Authors: Robert F Labadie; Ramya Balachandran; Jason E Mitchell; Jack H Noble; Omid Majdani; David S Haynes; Marc L Bennett; Benoit M Dawant; J Michael Fitzpatrick Journal: Otol Neurotol Date: 2010-01 Impact factor: 2.311
Authors: Louis B Kratchman; Daniel Schurzig; Theodore R McRackan; Ramya Balachandran; Jack H Noble; Robert J Webster; Robert F Labadie Journal: IEEE Trans Biomed Eng Date: 2012-07-25 Impact factor: 4.538
Authors: Jan-Philipp Kobler; Sergej Wall; G Jakob Lexow; Carl Philipp Lang; Omid Majdani; Lüder A Kahrs; Tobias Ortmaier Journal: Int J Comput Assist Radiol Surg Date: 2015-02-12 Impact factor: 2.924
Authors: Jan-Philipp Kobler; Michael Schoppe; G Jakob Lexow; Thomas S Rau; Omid Majdani; Lüder A Kahrs; Tobias Ortmaier Journal: Int J Comput Assist Radiol Surg Date: 2014-04-12 Impact factor: 2.924
Authors: Pooyan Rohani; Jason Pile; Lueder A Kahrs; Ramya Balachandran; Grégoire S Blachon; Nabil Simaan; Robert F Labadie Journal: Otolaryngol Head Neck Surg Date: 2014-01-27 Impact factor: 3.497