Literature DB >> 23591908

How to Manage a High Defibrillation Threshold in ICD Patients: and Does it Really Matter?

Maria Vittoria Matassini1, Jeff S Healey.   

Abstract

OPINION STATEMENT: In the 30 years since its introduction, implantable cardioverter defibrillator (ICD) hardware and programming has evolved greatly. Coupled with a better understanding of how patient factors and anti-arrhythmic drug therapy affect ICD function, these changes have resulted in a modern ICD system which is highly effective at terminating ventricular arrhythmias. This has led to a marked decrease in the conduct of intraoperative defibrillation testing. Still, clinicians are faced with patients who have had unsuccessful intraoperative defibrillation testing or who have experienced one or more failed clinical shocks for ventricular arrhythmias. Thus, clinicians caring for ICD patients must understand the expected performance of modern ICD systems, understand the issues with intraoperative defibrillation testing, and have a strategy for dealing with patients when their ICD has failed to terminate a clinical or induced ventricular arrhythmia. This review will focus on the clinical approach to such patients, including trouble-shooting and system revision.

Entities:  

Year:  2013        PMID: 23591908     DOI: 10.1007/s11936-013-0244-7

Source DB:  PubMed          Journal:  Curr Treat Options Cardiovasc Med        ISSN: 1092-8464


  46 in total

1.  Implantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.

Authors:  Rajmund Wilczek; Maciej Swiątkowski; Aleksandra Czepiel; Maciej Sterliński; Ewa Makowska; Piotr Kułakowski
Journal:  Kardiol Pol       Date:  2011       Impact factor: 3.108

2.  Effect of amiodarone and sotalol on ventricular defibrillation threshold: the optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial.

Authors:  Stefan H Hohnloser; Paul Dorian; Robin Roberts; Michael Gent; Carsten W Israel; Eric Fain; Jean Champagne; Stuart J Connolly
Journal:  Circulation       Date:  2006-07-03       Impact factor: 29.690

3.  High defibrillation thresholds in transvenous biphasic implantable defibrillators: clinical predictors and prognostic implications.

Authors:  Himanshu H Shukla; Greg C Flaker; Vinod Jayam; David Roberts
Journal:  Pacing Clin Electrophysiol       Date:  2003-01       Impact factor: 1.976

4.  Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?

Authors:  Andrea M Russo; William Sauer; Edward P Gerstenfeld; Henry H Hsia; David Lin; Joshua M Cooper; Sanjay Dixit; Ralph J Verdino; Hemal M Nayak; David J Callans; Vickas Patel; Francis E Marchlinski
Journal:  Heart Rhythm       Date:  2005-05       Impact factor: 6.343

5.  High defibrillation threshold in patients with implantable defibrillator: how effective is the subcutaneous finger lead?

Authors:  Brigitte R Osswald; Raffaele De Simone; Sabine Most; Ursula Tochtermann; Ahmed Tanzeem; Matthias Karck
Journal:  Eur J Cardiothorac Surg       Date:  2009-01-14       Impact factor: 4.191

6.  Effects of amiodarone and its active metabolite desethylamiodarone on the ventricular defibrillation threshold.

Authors:  L Zhou; B P Chen; J Kluger; C Fan; M S Chow
Journal:  J Am Coll Cardiol       Date:  1998-06       Impact factor: 24.094

7.  Comparison of fixed tilt and tuned defibrillation waveforms: the PROMISE study.

Authors:  Michael R Gold; Jesus Val-Mejias; Frank Cuoco; Mukkaram Siddiqui
Journal:  J Cardiovasc Electrophysiol       Date:  2012-12-04

8.  Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study.

Authors:  A E Epstein; K A Ellenbogen; K A Kirk; G N Kay; S M Dailey; V J Plumb
Journal:  Circulation       Date:  1992-10       Impact factor: 29.690

9.  Canadian Registry of ICD Implant Testing procedures (CREDIT): current practice, risks, and costs of intraoperative defibrillation testing.

Authors:  Jeff S Healey; Paul Dorian; L Brent Mitchell; Mario Talajic; Francois Philippon; Chris Simpson; Raymond Yee; Carlos A Morillo; Andre Lamy; Magdy Basta; David H Birnie; Xiaoyin Wang; Girish M Nair; Eugene Crystal; Charles R Kerr; Stuart J Connolly
Journal:  J Cardiovasc Electrophysiol       Date:  2009-10-05

10.  Complications associated with defibrillation threshold testing: the Canadian experience.

Authors:  David Birnie; Stanley Tung; Christopher Simpson; Eugene Crystal; Derek Exner; Felix-Alejandro Ayala Paredes; Andrew Krahn; Ratika Parkash; Yaariv Khaykin; Francois Philippon; Peter Guerra; Shane Kimber; Douglas Cameron; Jeffrey S Healey
Journal:  Heart Rhythm       Date:  2007-11-28       Impact factor: 6.343

View more
  4 in total

1.  ICD Shock, Not Ventricular Fibrillation, Causes Elevation of High Sensitive Troponin T after Defibrillation Threshold Testing--The Prospective, Randomized, Multicentre TropShock-Trial.

Authors:  Verena Semmler; Jürgen Biermann; Bernhard Haller; Clemens Jilek; Nikolaus Sarafoff; Carsten Lennerz; Hrvoje Vrazic; Bernhard Zrenner; Stefan Asbach; Christof Kolb
Journal:  PLoS One       Date:  2015-07-24       Impact factor: 3.240

2.  Traumatic Tension Pneumothorax as a Cause of ICD Failure: A Case Report and Review of the Literature.

Authors:  Ehtesham Ul Haq; Bassam Omar
Journal:  Case Rep Cardiol       Date:  2014-10-07

Review 3.  Implantable Cardioverter-Defibrillators for Secondary Prevention of Sudden Cardiac Death: A Review.

Authors:  Ryan T Borne; David Katz; Jarrod Betz; Pamela N Peterson; Frederick A Masoudi
Journal:  J Am Heart Assoc       Date:  2017-03-03       Impact factor: 5.501

4.  Analysis of Temporal Trends and Variation in the Use of Defibrillation Testing in Contemporary Practice.

Authors:  Ryan T Borne; Tiffany Randolph; Yongfei Wang; Jeptha P Curtis; Pamela N Peterson; Frederick A Masoudi; Amneet Sandhu; Matthew M Zipse; Kevin Thomas; Valentina Kutyifa; Nihar R Desai; Yong-Mei Cha; Jonathan C Hsu; Andrea M Russo
Journal:  JAMA Netw Open       Date:  2019-10-02
  4 in total