Complications associated with defibrillation threshold testing: the Canadian experience.

David Birnie1, Stanley Tung, Christopher Simpson, Eugene Crystal, Derek Exner, Felix-Alejandro Ayala Paredes, Andrew Krahn, Ratika Parkash, Yaariv Khaykin, Francois Philippon, Peter Guerra, Shane Kimber, Douglas Cameron, Jeffrey S Healey.   

Abstract

BACKGROUND: Defibrillation threshold (DFT) testing has traditionally been a routine part of implantable cardioverter-defibrillator (ICD) implantation, despite a lack of compelling evidence that it predicts or improves outcomes. In the past, when devices were much less reliable, DFT testing seemed prudent; however, modern ICD systems have such a high rate of successful defibrillation that many electrophysiologists now question whether DFT testing is still worthwhile, particularly since DFT testing may now be the highest acute risk component of ICD implantation.
OBJECTIVE: The purpose of this study was to systematically document complications directly attributable to intraoperative DFT testing.
METHODS: We obtained data on DFT-related complications from all 21 adult ICD implant centers in Canada, covering the period from January 1, 2000, to September 30, 2006.
RESULTS: There were a total of 19,067 ICD implants in Canada during the study period. There were three DFT testing-related deaths, five DFT testing-related strokes, and 27 episodes that required prolonged resuscitation. Two patients had significant clinical sequelae after prolonged resuscitation.
CONCLUSIONS: The risk of severe complications from intraoperative DFT testing appears small, even allowing for the underestimation of its true rate with the current study methodology. These slight but measurable risks must be considered when assessing the risk-benefit ratio of the procedure. Additional data from ongoing prospective ICD registries and/or clinical trials are required.

Entities:  

Mesh:

Year:  2007        PMID: 18243813     DOI: 10.1016/j.hrthm.2007.11.018

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  27 in total

1.  A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

Authors:  Peter Thomas Burke; Hamid Ghanbari; Patrick B Alexander; Michael K Shaw; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2010-01-29       Impact factor: 1.900

2.  [Is intraoperative ICD-testing still necessary?].

Authors:  C Mewis; H-R Neuberger; A Buob
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2010-06

Review 3.  Complications of defibrillation testing. A review of the literature.

Authors:  Bishoy Deif; Jeff S Healey
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-11-30

4.  Is defibrillation testing of ICDs necessary?

Authors:  J Lacy Sturdivant; Michael R Gold
Journal:  Nat Rev Cardiol       Date:  2012-10-02       Impact factor: 32.419

5.  Shock or no shock - a question of philosophy or should intraoperative implantable cardioverter defibrillator testing be recommended?

Authors:  Andreas Keyser; Michael K Hilker; Sebastian Schmidt; Christian von Bary; Wolfgang Zink; Michael Ried; Christof Schmid; Claudius Diez
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-12-07

6.  An Effective and Reproducible Model of Ventricular Fibrillation in Crossbred Yorkshire Swine (Sus scrofa) for Use in Physiologic Research.

Authors:  James M Burgert; Arthur D Johnson; Jose C Garcia-Blanco; W John Craig; Joseph C O'Sullivan
Journal:  Comp Med       Date:  2015-10       Impact factor: 0.982

7.  Effectiveness of VF induction with DC fibber versus conventional induction methods in patients on chronic amiodarone therapy.

Authors:  Jason C Rubenstein; Manish S Gupta; Michael H Kim
Journal:  J Interv Card Electrophysiol       Date:  2013-09-08       Impact factor: 1.900

Review 8.  Racial and gender disparities among patients with gout.

Authors:  Jasvinder A Singh
Journal:  Curr Rheumatol Rep       Date:  2013-02       Impact factor: 4.592

9.  How to Manage a High Defibrillation Threshold in ICD Patients: and Does it Really Matter?

Authors:  Maria Vittoria Matassini; Jeff S Healey
Journal:  Curr Treat Options Cardiovasc Med       Date:  2013-08

10.  Echocardiographic parameters to predict inadequate defibrillation safety margin in patients receiving implantable cardioverter defibrillators for primary prevention.

Authors:  Sachin Kumar Amruthlal Jain; Hamid Ghanbari; Rayan Hourani; Timothy R Larsen; Marcos Daccarett; Christian Machado
Journal:  J Interv Card Electrophysiol       Date:  2013-01-20       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.