Literature DB >> 23581278

Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets.

Norliza Ibrahim1, Azin Parsa, Bassam Hassan, Paul van der Stelt, Irene H A Aartman, Daniel Wismeijer.   

Abstract

OBJECTIVE: Cone-beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the system's limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CT (μCT).
MATERIALS AND METHODS: Twenty-four human mandibular cadavers were scanned using a CBCT system (80 μm) and a μCT system (35 μm). Three bone microstructural parameters trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp) were assessed using CTAn imaging software.
RESULTS: Intraclass correlation coefficients (ICC) showed a high intra-observer reliability (≥ 0.996) in all parameters for both systems. The Pearson correlation coefficients between the measurements of the two systems were for Tb.Th 0.82, for Tb.Sp 0.94 and for Tb.N 0.85 (all P's<0.001). The Bland and Altman plots showed strongest agreement in Tb.N (-0.37 μm) followed by Tb.Th (1.6 μm) and Tb.Sp (8.8 μm).
CONCLUSIONS: Cone-beam CT datasets can be used to evaluate trabecular bone microstructure at dental implant sites. The accuracy for measuring Tb.N was the best followed by Tb.Th and Tb.Sp.
© 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

Entities:  

Keywords:  cone-beam computed tomography; dental implants; micro-computed tomography; microarchitecture; trabecular bone

Mesh:

Substances:

Year:  2013        PMID: 23581278     DOI: 10.1111/clr.12163

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  19 in total

1.  The effect of scan parameters on cone beam CT trabecular bone microstructural measurements of the human mandible.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013-10-16       Impact factor: 2.419

2.  Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; I H A Aartman; P Nambiar
Journal:  Dentomaxillofac Radiol       Date:  2013-11-21       Impact factor: 2.419

3.  Comparison of mandibular bone microarchitecture between micro-CT and CBCT images.

Authors:  S Panmekiate; N Ngonphloy; T Charoenkarn; T Faruangsaeng; R Pauwels
Journal:  Dentomaxillofac Radiol       Date:  2015-01-07       Impact factor: 2.419

Review 4.  Capability of CBCT to identify patients with low bone mineral density: a systematic review.

Authors:  Eliete N S Guerra; Fabiana T Almeida; Fernanda V Bezerra; Paulo T D S Figueiredo; Maria A G Silva; Graziela De Luca Canto; Camila Pachêco-Pereira; André F Leite
Journal:  Dentomaxillofac Radiol       Date:  2017-07-03       Impact factor: 2.419

5.  Trabecular bone histomorphometric measurements and contrast-to-noise ratio in CBCT.

Authors:  E Klintström; O Smedby; B Klintström; T B Brismar; R Moreno
Journal:  Dentomaxillofac Radiol       Date:  2014-08-29       Impact factor: 2.419

6.  Effect of exposure parameters and voxel size on bone structure analysis in CBCT.

Authors:  R Pauwels; T Faruangsaeng; T Charoenkarn; N Ngonphloy; S Panmekiate
Journal:  Dentomaxillofac Radiol       Date:  2015-06-09       Impact factor: 2.419

7.  Validation of CBCT for the computation of textural biomarkers.

Authors:  Beatriz Paniagua; Antonio Carlos Ruellas; Erika Benavides; Steve Marron; Larry Woldford; Lucia Cevidanes
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17

8.  Accuracy of biomarkers obtained from cone beam computed tomography in assessing the internal trabecular structure of the mandibular condyle.

Authors:  Fouad H Ebrahim; Antonio C O Ruellas; Beatriz Paniagua; Erika Benavides; Karl Jepsen; Larry Wolford; Joao Roberto Goncalves; Lucia H S Cevidanes
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2017-08-24

9.  Quantitative analysis of metal artefacts of dental implant in CBCT image by correlation analysis to micro-CT: A microstructural study.

Authors:  Chang-Ki Min; Kyoung-A Kim
Journal:  Dentomaxillofac Radiol       Date:  2020-10-08       Impact factor: 2.419

10.  Distribution of mandibular trabeculae bone volume fraction in relation to different MOP intervals for accelerating orthodontic tooth movement.

Authors:  Ng Heng Khiang Teh; Saritha Sivarajan; Muhammad Khan Asif; Norliza Ibrahim; Mang Chek Wey
Journal:  Angle Orthod       Date:  2020-11-01       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.