Low radiation dose protocol in cardiac CT with 100 kVp: usefulness of display preset optimization.

Takeshi Nakaura1, Masafumi Kidoh, Naritsugu Sakaino, Shota Nakamura, Toshimitsu Nozaki, Akari Izumi, Kazunori Harada, Yasuyuki Yamashita.   

Abstract

To evaluate the radiation dose and image quality of 100 kVp cardiac CT, and the effects of display setting optimization. We randomly assigned 100 patients undergoing cardiac CT to one of following two protocols. Fifty patients underwent our conventional protocol with 120 kVp, and the other 50 patients underwent our low radiation dose protocol with 100 kVp. We compared effective dose (ED); CT number, image noise, and contrast noise ratio (CNR) of ascending aorta at 120 and 100 kVp protocol. We also performed quantitative analysis and qualitative analysis for bitmap image of 120, 100 kVp, and display preset optimization for 100 kVp images. The estimated ED was 48 % lower with the 100 kVp protocol than the 120 kVp protocol (2.8 vs. 5.5 mSv, p < 0.01). There is no significant difference in the CNR between 100 and 120 kVp protocol (18.5 ± 3.6 vs. 18.6 ± 3.8, p = 0.84). Display preset optimization significantly improved image quality of 100 kVp cardiac CT, and there is no significant difference in qualitative analysis and quantitative analysis between 100 kVp scan with optimized display preset and 120 kVp scan (p > 0.05). The 100 kVp scanning with optimized display preset offers almost same image quality at cardiac CT of thin adults under 48 % decreased radiation dose.

Entities:  

Mesh:

Year:  2013        PMID: 23568561     DOI: 10.1007/s10554-013-0214-x

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  26 in total

1.  Technique factors and image quality as functions of patient weight at abdominal CT.

Authors:  W Huda; E M Scalzetti; G Levin
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings.

Authors:  Claudia Schueller-Weidekamm; Cornelia M Schaefer-Prokop; Michael Weber; Christian J Herold; Mathias Prokop
Journal:  Radiology       Date:  2006-12       Impact factor: 11.105

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  Low-kilovoltage, high-tube-current MDCT of liver in thin adults: pilot study evaluating radiation dose, image quality, and display settings.

Authors:  Takeshi Nakaura; Kazuo Awai; Seitaro Oda; Yoshinori Funama; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2011-06       Impact factor: 3.959

6.  Acute stroke: improved nonenhanced CT detection--benefits of soft-copy interpretation by using variable window width and center level settings.

Authors:  M H Lev; J Farkas; J J Gemmete; S T Hossain; G J Hunter; W J Koroshetz; R G Gonzalez
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

7.  Lower tube voltage reduces contrast material and radiation doses on 16-MDCT aortography.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Duo Liu; Takeshi Nakaura; Yoshitaka Tamura; Yasuyuki Yamashita
Journal:  AJR Am J Roentgenol       Date:  2006-11       Impact factor: 3.959

8.  Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise.

Authors:  Yoshiharu Nakayama; Kazuo Awai; Yoshinori Funama; Masahiro Hatemura; Masanori Imuta; Takeshi Nakaura; Da Ryu; Shoji Morishita; Shamima Sultana; Natsuko Sato; Yasuyuki Yamashita
Journal:  Radiology       Date:  2005-10-19       Impact factor: 11.105

9.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  3 in total

1.  Diagnosis of small posterior fossa stroke on brain CT: effect of iterative reconstruction designed for brain CT on detection performance.

Authors:  Taihei Inoue; Takeshi Nakaura; Morikatsu Yoshida; Koichi Yokoyama; Kenichiro Hirata; Masafumi Kidoh; Seitaro Oda; Daisuke Utsunomiya; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-03-08       Impact factor: 5.315

Review 2.  Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.

Authors:  Sock Keow Tan; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Kwan Hoong Ng; Yang Faridah Abdul Aziz; Kok Han Chee; Zhonghua Sun
Journal:  Br J Radiol       Date:  2018-03-29       Impact factor: 3.039

3.  Cardiac helical CT involving a low-radiation-dose protocol with a 100-kVp setting: Usefulness of hybrid iterative reconstruction and display preset optimization.

Authors:  Yuji Iyama; Takeshi Nakaura; Koichi Yokoyama; Masafumi Kidoh; Yasuyuki Yamashita
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.