Literature DB >> 23567009

Continuous glucose monitoring: evidence and consensus statement for clinical use.

Andreas Liebl1, Helmut R Henrichs, Lutz Heinemann, Guido Freckmann, Eberhard Biermann, Andreas Thomas.   

Abstract

Continuous glucose monitoring (CGM) is an essential tool for modern diabetes therapy. Randomized controlled studies have provided evidence that hemoglobin A1c (HbA1c) results can be improved in patients with type 1 diabetes with elevated baseline HbA1c when using CGM frequently enough and that the frequency and duration of hypoglycemic events can be reduced in patients with satisfactory baseline HbA1c. The CGM group within the Working Group Diabetes Technology (AGDT) of the German Diabetes Association (DDG) has defined evidence-based indications for the practical use of CGM in this consensus statement related to hypoglycemia (frequent, severe, or nocturnal) or hypoglycemia unawareness, insufficient metabolic control despite use of all possible therapeutic options and patient compliance, pregnancy associated with inadequate blood glucose results, and the need for more than 10 blood glucose measurements per day. Contraindications and defined preconditions for the successful use of CGM should be considered.
© 2013 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23567009      PMCID: PMC3737652          DOI: 10.1177/193229681300700227

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  53 in total

1.  Comparison of the numerical and clinical accuracy of four continuous glucose monitors.

Authors:  Boris Kovatchev; Stacey Anderson; Lutz Heinemann; William Clarke
Journal:  Diabetes Care       Date:  2008-03-13       Impact factor: 19.112

2.  Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?

Authors:  Roger S Mazze; Ellie Strock; Sarah Borgman; David Wesley; Philip Stout; Joel Racchini
Journal:  Diabetes Technol Ther       Date:  2009-01       Impact factor: 6.118

3.  Prolonged use of continuous glucose monitors in children with type 1 diabetes on continuous subcutaneous insulin infusion or intensive multiple-daily injection therapy.

Authors:  Stuart Weinzimer; Dongyuan Xing; Michael Tansey; Rosanna Fiallo-Scharer; Nelly Mauras; Tim Wysocki; Roy Beck; William Tamborlane; Katrina Ruedy
Journal:  Pediatr Diabetes       Date:  2008-10-20       Impact factor: 4.866

4.  Summary of revisions for the 2009 Clinical Practice Recommendations.

Authors: 
Journal:  Diabetes Care       Date:  2009-01       Impact factor: 19.112

5.  Continuous glucose monitoring counseling improves physical activity behaviors of individuals with type 2 diabetes: A randomized clinical trial.

Authors:  Nancy A Allen; James A Fain; Barry Braun; Stuart R Chipkin
Journal:  Diabetes Res Clin Pract       Date:  2008-03-04       Impact factor: 5.602

6.  Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study.

Authors:  Irl B Hirsch; Jill Abelseth; Bruce W Bode; Jerome S Fischer; Francine R Kaufman; John Mastrototaro; Christopher G Parkin; Howard A Wolpert; Bruce A Buckingham
Journal:  Diabetes Technol Ther       Date:  2008-10       Impact factor: 6.118

7.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

8.  Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems.

Authors:  Satish K Garg; James Smith; Christie Beatson; Benita Lopez-Baca; Mary Voelmle; Peter A Gottlieb
Journal:  Diabetes Technol Ther       Date:  2009-02       Impact factor: 6.118

9.  Feasibility of 10-day use of a continuous glucose-monitoring system in adults with type 1 diabetes.

Authors:  Satish K Garg; Mary K Voelmle; Peter Gottlieb
Journal:  Diabetes Care       Date:  2008-11-25       Impact factor: 19.112

10.  Effectiveness of continuous glucose monitoring in pregnant women with diabetes: randomised clinical trial.

Authors:  Helen R Murphy; Gerry Rayman; Karen Lewis; Susan Kelly; Balroop Johal; Katherine Duffield; Duncan Fowler; Peter J Campbell; Rosemary C Temple
Journal:  BMJ       Date:  2008-09-25
View more
  21 in total

1.  Continuous Glucose Monitoring After Gastric Bypass to Evaluate the Glucose Variability After a Low-Carbohydrate Diet and to Determine Hypoglycemia.

Authors:  Joan Bach Nielsen; Caroline Bruun Abild; Ane Mathilde Pedersen; Steen Bønløkke Pedersen; Bjørn Richelsen
Journal:  Obes Surg       Date:  2016-09       Impact factor: 4.129

Review 2.  [New technologies in diabetology. How far are we from a closed loop?].

Authors:  G Freckmann
Journal:  Internist (Berl)       Date:  2015-05       Impact factor: 0.743

3.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

Review 4.  The benefits, limitations, and cost-effectiveness of advanced technologies in the management of patients with diabetes mellitus.

Authors:  Robert A Vigersky
Journal:  J Diabetes Sci Technol       Date:  2015-03

Review 5.  Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.

Authors:  David Rodbard
Journal:  Diabetes Technol Ther       Date:  2017-06       Impact factor: 6.118

6.  The Comprehensive Glucose Pentagon: A Glucose-Centric Composite Metric for Assessing Glycemic Control in Persons With Diabetes.

Authors:  Robert A Vigersky; John Shin; Boyi Jiang; Thorsten Siegmund; Chantal McMahon; Andreas Thomas
Journal:  J Diabetes Sci Technol       Date:  2017-07-27

Review 7.  Technology to Reduce Hypoglycemia.

Authors:  Ester Yeoh; Pratik Choudhary
Journal:  J Diabetes Sci Technol       Date:  2015-04-16

8.  Feasibility of Factory Calibration for Subcutaneous Glucose Sensors in Subjects With Diabetes.

Authors:  Udo Hoss; Erwin S Budiman; Hanqing Liu; Mark P Christiansen
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

9.  Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes.

Authors:  B Bonora; A Maran; S Ciciliot; A Avogaro; G P Fadini
Journal:  J Endocrinol Invest       Date:  2016-06-10       Impact factor: 4.256

10.  Safety and feasibility of a factory-calibrated continuous glucose monitoring system in term and near-term infants at risk of hypoglycemia.

Authors:  Eri Nishimura; Shuntaro Oka; Junichi Ozawa; Kosuke Tanaka; Taichi Momose; Kazuhiko Kabe; Fumihiko Namba
Journal:  Turk Arch Pediatr       Date:  2021-01-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.