Literature DB >> 23535285

Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty.

Bart J Vundelinckx1, Liesbeth Bruckers, Kris De Mulder, Jo De Schepper, Gert Van Esbroeck.   

Abstract

Patient matched instrumentation is a new operative tool in the field of total knee arthroplasty. Custom made cutting blocks are designed to perform distal femoral and tibial bone cuts according to a pre-operative planning. This study evaluates the Visionaire system of Smith & Nephew. Thirty-one patients, operated with the Visionaire technique, were compared to an equal control group for different clinical and radiographic outcome parameters. Between both groups, no statistical significant difference could be found in post-operative pain, satisfaction, functional outcome, hospital stay, blood loss, radiographic alignment and precision of bone cuts. Only tibial plateau backslope can be created with more precision in the Visionaire group. But there was a statistical significant difference for residual flexion deformity after a mean follow-up time of 200 days.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23535285     DOI: 10.1016/j.arth.2012.09.010

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  29 in total

1.  Stability and alignment do not improve by using patient-specific instrumentation in total knee arthroplasty: a randomized controlled trial.

Authors:  Nienke M Kosse; Petra J C Heesterbeek; Janneke J P Schimmel; Gijs G van Hellemondt; Ate B Wymenga; Koen C Defoort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-11-28       Impact factor: 4.342

2.  Custom cutting guides in total knee arthroplasty.

Authors:  Morad Chughtai; Anton Khlopas; Iyooh U Davidson; George A Yakubek; Kim L Stearns; Michael A Mont
Journal:  Ann Transl Med       Date:  2017-05

3.  How are we addressing ligament balance in TKA? A literature review of revision etiology and technological advancement.

Authors:  Tyler Smith; Leah Elson; Christopher Anderson; William Leone
Journal:  J Clin Orthop Trauma       Date:  2016-08-03

Review 4.  Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis.

Authors:  Etienne Cavaignac; Regis Pailhé; Gregoire Laumond; Jérôme Murgier; Nicolas Reina; Jean Michel Laffosse; Emilie Bérard; Philippe Chiron
Journal:  Int Orthop       Date:  2014-10-10       Impact factor: 3.075

5.  Handheld Navigation Device and Patient-Specific Cutting Guides Result in Similar Coronal Alignment for Primary Total Knee Arthroplasty: a Retrospective Matched Cohort Study.

Authors:  Michael E Steinhaus; Alexander S McLawhorn; Shawn S Richardson; Patrick Maher; David J Mayman
Journal:  HSS J       Date:  2016-02-29

Review 6.  Patient-specific instruments in total knee arthroplasty.

Authors:  Fabio Conteduca; Raffaele Iorio; Daniele Mazza; Andrea Ferretti
Journal:  Int Orthop       Date:  2014-01-07       Impact factor: 3.075

7.  The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty?

Authors:  Emmanuel Thienpont; Irina Grosu; Frederic Paternostre; Pierre-Emmanuel Schwab; Jean Cyr Yombi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-27       Impact factor: 4.342

8.  Verification of in vivo accuracy of Trumatch™ patient-specific instrumentation in total knee replacement using pin-less computer navigation.

Authors:  Nikolai Briffa; Mohamed A Imam; Ravi Mallina; Ashraf Abdelkafy; Ajeya Adhikari
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-09-07

Review 9.  Systematic review of patient-specific instrumentation in total knee arthroplasty: new but not improved.

Authors:  Adam Sassoon; Denis Nam; Ryan Nunley; Robert Barrack
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

10.  Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation.

Authors:  Meng Zhu; Jerry Yongqiang Chen; Hwei Chi Chong; Andy Khye Soon Yew; Leon Siang Shen Foo; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-26       Impact factor: 4.342

View more