BACKGROUND: Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumptions. QUESTIONS/PURPOSES: We asked: (1) Do patient-specific cutting blocks achieve neutral mechanical alignment more reliably during TKA when compared with conventional methods? (2) Does patient-specific instrumentation (PSI) provide financial benefit through improved surgical efficiency? (3) Does the use of patient-specific cutting blocks translate to improved clinical results after TKA when compared with conventional instrumentation? METHODS: We performed a systematic review in accordance with Cochrane guidelines of controlled studies (prospective and retrospective) in MEDLINE® and EMBASE® with respect to patient-specific cutting blocks and their effect on alignment, cost, operative time, clinical outcome scores, complications, and survivorship. Sixteen studies (Level I-III on the levels of evidence rubric) were identified and used in addressing the first question, 13 (Level I-III) for the second question, and two (Level III) for the third question. Qualitative assessment of the selected Level I studies was performed using the modified Jadad score; Level II and III studies were rated based on the Newcastle-Ottawa scoring system. RESULTS: The majority of studies did not show an improvement in overall limb alignment when PSI was compared with standard instrumentation. Mixed results were seen across studies with regard to the prevalence of alignment outliers when PSI was compared with conventional cutting blocks with some studies demonstrating no difference, some showing an improvement with PSI, and a single study showing worse results with PSI. The studies demonstrated mixed results regarding the influence of PSI on operative times. Decreased operative times were not uniformly observed, and when noted, they were found to be of minimal clinical or financial significance. PSI did reliably reduce the number of instrument trays required for processing perioperatively. The accuracy of the preoperative plan, generated by the PSI manufacturers, was found lacking, often leading to multiple intraoperative changes, thereby disrupting the flow of the operation and negatively impacting efficiency. Limited data exist with regard to the effect of PSI on postoperative function, improvement in pain, and patient satisfaction. Neither of the two studies we identified provided strong evidence to support an advantage favoring the use of PSI. No identified studies addressed survivorship of components placed with PSI compared with those placed with standard instrumentation. CONCLUSIONS: PSI for TKA has not reliably demonstrated improvement of postoperative limb or component alignment when compared with standard instrumentation. Although decisive evidence exists to support that PSI requires fewer surgical trays, PSI has not clearly been shown to improve overall surgical efficiency or the cost-effectiveness of TKA. Mid- and long-term data regarding PSI's effect on functional outcomes and component survivorship do not exist and short-term data are scarce. Limited available literature does not clearly support any improvement of postoperative pain, activity, function, or ROM when PSI is compared with traditional instrumentation.
BACKGROUND:Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumptions. QUESTIONS/PURPOSES: We asked: (1) Do patient-specific cutting blocks achieve neutral mechanical alignment more reliably during TKA when compared with conventional methods? (2) Does patient-specific instrumentation (PSI) provide financial benefit through improved surgical efficiency? (3) Does the use of patient-specific cutting blocks translate to improved clinical results after TKA when compared with conventional instrumentation? METHODS: We performed a systematic review in accordance with Cochrane guidelines of controlled studies (prospective and retrospective) in MEDLINE® and EMBASE® with respect to patient-specific cutting blocks and their effect on alignment, cost, operative time, clinical outcome scores, complications, and survivorship. Sixteen studies (Level I-III on the levels of evidence rubric) were identified and used in addressing the first question, 13 (Level I-III) for the second question, and two (Level III) for the third question. Qualitative assessment of the selected Level I studies was performed using the modified Jadad score; Level II and III studies were rated based on the Newcastle-Ottawa scoring system. RESULTS: The majority of studies did not show an improvement in overall limb alignment when PSI was compared with standard instrumentation. Mixed results were seen across studies with regard to the prevalence of alignment outliers when PSI was compared with conventional cutting blocks with some studies demonstrating no difference, some showing an improvement with PSI, and a single study showing worse results with PSI. The studies demonstrated mixed results regarding the influence of PSI on operative times. Decreased operative times were not uniformly observed, and when noted, they were found to be of minimal clinical or financial significance. PSI did reliably reduce the number of instrument trays required for processing perioperatively. The accuracy of the preoperative plan, generated by the PSI manufacturers, was found lacking, often leading to multiple intraoperative changes, thereby disrupting the flow of the operation and negatively impacting efficiency. Limited data exist with regard to the effect of PSI on postoperative function, improvement in pain, and patient satisfaction. Neither of the two studies we identified provided strong evidence to support an advantage favoring the use of PSI. No identified studies addressed survivorship of components placed with PSI compared with those placed with standard instrumentation. CONCLUSIONS: PSI for TKA has not reliably demonstrated improvement of postoperative limb or component alignment when compared with standard instrumentation. Although decisive evidence exists to support that PSI requires fewer surgical trays, PSI has not clearly been shown to improve overall surgical efficiency or the cost-effectiveness of TKA. Mid- and long-term data regarding PSI's effect on functional outcomes and component survivorship do not exist and short-term data are scarce. Limited available literature does not clearly support any improvement of postoperative pain, activity, function, or ROM when PSI is compared with traditional instrumentation.
Authors: John B Meding; Michael E Berend; Merrill A Ritter; Matthew R Galley; Robert A Malinzak Journal: J Arthroplasty Date: 2011-06 Impact factor: 4.757
Authors: Ryan M Nunley; Bradley S Ellison; Erin L Ruh; Brandon M Williams; Keith Foreman; Adrienne D Ford; Robert L Barrack Journal: Clin Orthop Relat Res Date: 2011-12-20 Impact factor: 4.176
Authors: Merrill A Ritter; Kenneth E Davis; John B Meding; Jeffery L Pierson; Michael E Berend; Robert A Malinzak Journal: J Bone Joint Surg Am Date: 2011-09-07 Impact factor: 5.284
Authors: C H Pang; W L Chan; C H Yen; S C Cheng; S B Woo; S T Choi; W K Hui; K H Mak Journal: J Orthop Surg (Hong Kong) Date: 2009-08 Impact factor: 1.118
Authors: Constantin Mayer; Alexander Franz; Jan-Frieder Harmsen; Fina Queitsch; Michael Behringer; Johannes Beckmann; Rüdiger Krauspe; Christoph Zilkens Journal: J Orthop Date: 2017-06-24
Authors: Eric Alexander Lewallen; Scott M Riester; Carolina A Bonin; Hilal Maradit Kremers; Amel Dudakovic; Sanjeev Kakar; Robert C Cohen; Jennifer J Westendorf; David G Lewallen; Andre J van Wijnen Journal: Tissue Eng Part B Rev Date: 2014-12-18 Impact factor: 6.389
Authors: Mo Saffarini; Jacobus H Müller; Giuseppe La Barbera; Gerjon Hannink; Kyung Jin Cho; Cécile Toanen; David Dejour Journal: Knee Surg Sports Traumatol Arthrosc Date: 2017-03-07 Impact factor: 4.342