Literature DB >> 23516032

Low rate of dislocation of dual-mobility cups in primary total hip arthroplasty.

Antoine Combes1, Henri Migaud, Julien Girard, Alain Duhamel, Michel Henri Fessy.   

Abstract

BACKGROUND: Dual-mobility (DM) cups were introduced to minimize the risk of THA dislocation. The overall rate of dislocation of DM cups (including both large and small articulations) is controversial and ranges from 0% to 5% in previous studies. QUESTIONS/PURPOSES: We therefore recorded (1) the dislocation rate, (2) loosening and osteolysis, and (3) subsequent related revisions with DM cups.
METHODS: Between 1998 and 2003, 2480 primary THAs with DM cups were undertaken in 2179 patients. The mean age was 69 years (range, 19-94 years). This group underwent specific clinical and radiographic evaluation at a minimum followup of 0.17 years (mean, 7 years; range, 0.17-11 years) to assess dislocation, reoperation, osteolysis, and cup fixation.
RESULTS: There were 22 dislocations (0.88%): 15 dislocations of large articulations (0.6%), with two (0.08%) recurring but only one requiring revision (0.04%), and seven intraprosthetic small articulation dislocations (0.28%), all needing revision surgery. At last followup, mean Harris hip score was 91 (range, 60-100); 2439 cups (98%) showed no signs of loosening; and 141 patients (145 hips) had osteolysis (6%). Osteolysis and cup loosening were more frequent in patients younger than 50 years at the time of surgery. The 10-year survivorship considering revision for any reason was 93% (95% CI, 91%-95%).
CONCLUSIONS: DM cups had a low dislocation rate in primary THA, with a limited frequency of adverse effects. We recommend DM cups to minimize dislocation in populations at high risk for instability, but they should be avoided in younger, active patients at higher risk for osteolysis.

Entities:  

Mesh:

Year:  2013        PMID: 23516032      PMCID: PMC3825881          DOI: 10.1007/s11999-013-2929-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  36 in total

1.  [Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants].

Authors:  P Adam; F Farizon; M-H Fessy
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-11

2.  Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results.

Authors:  R C Johnston; R H Fitzgerald; W H Harris; R Poss; M E Müller; C B Sledge
Journal:  J Bone Joint Surg Am       Date:  1990-02       Impact factor: 5.284

3.  The multifactorial nature of polyethylene wear in vivo.

Authors:  T P Schmalzried; F J Dorey; H McKellop
Journal:  J Bone Joint Surg Am       Date:  1998-08       Impact factor: 5.284

4.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  Evaluation of cementless acetabular component migration. An experimental study.

Authors:  P Massin; L Schmidt; C A Engh
Journal:  J Arthroplasty       Date:  1989-09       Impact factor: 4.757

6.  [Numerical evaluation of hip function].

Authors:  R Merle D'Augibné
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1970 Jul-Aug

7.  Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial.

Authors:  P A Devane; E J Robinson; R B Bourne; C H Rorabeck; N N Nayak; J G Horne
Journal:  J Bone Joint Surg Am       Date:  1997-05       Impact factor: 5.284

8.  Hospital cost of dislocation after primary total hip arthroplasty.

Authors:  Joaquin Sanchez-Sotelo; George J Haidukewych; Carol J Boberg
Journal:  J Bone Joint Surg Am       Date:  2006-02       Impact factor: 5.284

9.  Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.

Authors:  J C Clohisy; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1999-02       Impact factor: 5.284

10.  An analysis of the risk of hip dislocation with a contemporary total joint registry.

Authors:  Monti Khatod; Thomas Barber; Elizabeth Paxton; Robert Namba; Donald Fithian
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

View more
  46 in total

Review 1.  Intra-prosthetic dislocation of dual-mobility cups after total hip arthroplasty: potential causes from a clinical and biomechanical perspective.

Authors:  Christian Fabry; Jean Langlois; Moussa Hamadouche; Rainer Bader
Journal:  Int Orthop       Date:  2015-10-01       Impact factor: 3.075

2.  Dual mobility cups in revision total hip arthroplasty.

Authors:  Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2016-12-08       Impact factor: 3.075

Review 3.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

4.  Equivalent wear performance of dual mobility bearing compared with standard bearing in total hip arthroplasty: in vitro study.

Authors:  Gaël Gaudin; André Ferreira; Romain Gaillard; Jean Louis Prudhon; Jacques H Caton; Sébastien Lustig
Journal:  Int Orthop       Date:  2016-11-22       Impact factor: 3.075

5.  Short-term outcome after total hip arthroplasty using dual-mobility cup: report from Lithuanian Arthroplasty Register.

Authors:  Sarunas Tarasevicius; Alfredas Smailys; Kazimieras Grigaitis; Otto Robertsson; Justinas Stucinskas
Journal:  Int Orthop       Date:  2017-01-12       Impact factor: 3.075

6.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

Review 7.  Wear of dual-mobility cups: a review article.

Authors:  Anna Di Laura; Harry Hothi; Clement Battisti; Arianna Cerquiglini; Johann Henckel; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-12-09       Impact factor: 3.075

Review 8.  Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision.

Authors:  Philippe Hernigou; Arnaud Dubory; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2016-11-21       Impact factor: 3.075

9.  Dual-mobility or Constrained Liners Are More Effective Than Preoperative Bariatric Surgery in Prevention of THA Dislocation.

Authors:  Philippe Hernigou; Matthieu Trousselier; François Roubineau; Charlie Bouthors; Charles Henri Flouzat Lachaniette
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

Review 10.  Total hip arthroplasty in acetabular fractures.

Authors:  Deepak Gautam; Saurabh Gupta; Rajesh Malhotra
Journal:  J Clin Orthop Trauma       Date:  2020-10-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.