Literature DB >> 9160940

Measurement of polyethylene wear in acetabular components inserted with and without cement. A randomized trial.

P A Devane1, E J Robinson, R B Bourne, C H Rorabeck, N N Nayak, J G Horne.   

Abstract

We measured the three-dimensional wear of polyethylene after total hip arthroplasty with a titanium metal-backed Mallory-Head prosthesis that was inserted with cement in sixty-nine patients (sixty-nine hips) and with a press-fit titanium metal-backed Mallory-Head prosthesis that was inserted without cement in seventy patients (seventy hips). A modular titanium femoral head was used in all of the hips. The patients in the present study were part of a larger double-blind randomized trial comparing the result of total hip arthroplasty performed with cement with that of the same procedure performed without cement in 250 patients. The criterion for inclusion in the study of polyethylene wear was a minimum duration of follow-up of four years, which was met by 148 patients. As adequate radiographs for digitization were not available for nine patients, 139 patients were included in the present study. The age of the patient, the postoperative Harris hip score, the diameter of the femoral head, the thickness of the liner in the polar region of the acetabular component, and the duration of follow-up were similar for the two groups. The mean rate of volumetric wear of the polyethylene was significantly greater in the prostheses that had been inserted without cement than in those that had been inserted with cement (155.1 cubic millimeters per year compared with 98.5 cubic millimeters per year; p = 0.000008). Thirty-four (49 per cent) of the seventy hips in which the prosthesis had been inserted without cement had evidence of osteolysis on radiographs, compared with twelve (17 per cent) of the sixty-nine hips in the other group (p = 0.0002). Osteolysis was associated with an increased rate of polyethylene wear only in the hips in which the prosthesis had been inserted without cement.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9160940     DOI: 10.2106/00004623-199705000-00007

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  13 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

Review 2.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

3.  Long-term results of cementless femoral reconstruction following intertrochanteric osteotomy.

Authors:  Christian Merle; Marcus R Streit; Moritz Innmann; Tobias Gotterbarm; Peter R Aldinger
Journal:  Int Orthop       Date:  2012-01-12       Impact factor: 3.075

4.  Bone remodeling around stable uncemented titanium stems during the second decade after total hip arthroplasty: a DXA study at 12 and 17 years.

Authors:  C Merle; M R Streit; C Volz; M Pritsch; T Gotterbarm; P R Aldinger
Journal:  Osteoporos Int       Date:  2010-11-23       Impact factor: 4.507

Review 5.  2009 Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear.

Authors:  Thomas D Brown; Hannah J Lundberg; Douglas R Pedersen; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2009-04-28       Impact factor: 4.176

6.  Total knee arthroplasty in patients with varus deformities greater than ten degrees: survival analysis at a mean ten year follow-up.

Authors:  Benjamin Puliero; Henri Favreau; David Eichler; Philippe Adam; François Bonnomet; Matthieu Ehlinger
Journal:  Int Orthop       Date:  2018-06-21       Impact factor: 3.075

Review 7.  Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Authors:  Deborah A Marshall; Karen Pykerman; Jason Werle; Diane Lorenzetti; Tracy Wasylak; Tom Noseworthy; Donald A Dick; Greg O'Connor; Aish Sundaram; Sanne Heintzbergen; Cy Frank
Journal:  Clin Orthop Relat Res       Date:  2014-04-04       Impact factor: 4.176

8.  Low rate of dislocation of dual-mobility cups in primary total hip arthroplasty.

Authors:  Antoine Combes; Henri Migaud; Julien Girard; Alain Duhamel; Michel Henri Fessy
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Recurrence of dislocation following total hip arthroplasty revision using dual mobility cups was rare in 180 hips followed over 7 years.

Authors:  Patrice Mertl; Antoine Combes; Frédérique Leiber-Wackenheim; Michel Henri Fessy; Julien Girard; Henri Migaud
Journal:  HSS J       Date:  2012-09-19

10.  Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Ali Abdulkarim; Prasad Ellanti; Nicola Motterlini; Tom Fahey; John M O'Byrne
Journal:  Orthop Rev (Pavia)       Date:  2013-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.