Literature DB >> 23493224

Can sinogram-affirmed iterative (SAFIRE) reconstruction improve imaging quality on low-dose lung CT screening compared with traditional filtered back projection (FBP) reconstruction?

Wen Jie Yang1, Fu Hua Yan, Bo Liu, Li Fang Pang, Liang Hou, Huan Zhang, Zi Lai Pan, Ke Min Chen.   

Abstract

OBJECTIVE: To evaluate the performance of sinogram-affirmed iterative (SAFIRE) reconstruction on image quality of low-dose lung computed tomographic (CT) screening compared with filtered back projection (FBP).
METHODS: Three hundred four patients for annual low-dose lung CT screening were examined by a dual-source CT system at 120 kilovolt (peak) with reference tube current of 40 mA·s. Six image serials were reconstructed, including one data set of FBP and 5 data sets of SAFIRE with different reconstruction strengths from 1 to 5. Image noise was recorded; and subjective scores of image noise, images artifacts, and the overall image quality were also assessed by 2 radiologists.
RESULTS: The mean ± SD weight for all patients was 66.3 ± 12.8 kg, and the body mass index was 23.4 ± 3.2. The mean ± SD dose-length product was 95.2 ± 30.6 mGy cm, and the mean ± SD effective dose was 1.6 ± 0.5 mSv. The observation agreements for image noise grade, artifact grade, and the overall image quality were 0.785, 0.595 and 0.512, respectively. Among the overall 6 data sets, both the measured mean objective image noise and the subjective image noise of FBP was the highest, and the image noise decreased with the increasing of SAFIRE reconstruction strength. The data sets of S3 obtained the best image quality scores.
CONCLUSION: Sinogram-affirmed iterative reconstruction can significantly improve image quality of low-dose lung CT screening compared with FBP, and SAFIRE with reconstruction strength 3 was a pertinent choice for low-dose lung CT.

Entities:  

Mesh:

Year:  2013        PMID: 23493224     DOI: 10.1097/RCT.0b013e31827b8c66

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  20 in total

1.  Computer-assisted solid lung nodule 3D volumetry on CT: influence of scan mode and iterative reconstruction: a CT phantom study.

Authors:  Adriaan Coenen; Osamu Honda; Eric J van der Jagt; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2013-08-18       Impact factor: 2.374

2.  High-pitch computed tomography pulmonary angiography with iterative reconstruction at 80 kVp and 20 mL contrast agent volume.

Authors:  Guang Ming Lu; Song Luo; Felix G Meinel; Andrew D McQuiston; Chang Sheng Zhou; Xiang Kong; Yan E Zhao; Ling Zheng; U Joseph Schoepf; Long Jiang Zhang
Journal:  Eur Radiol       Date:  2014-08-07       Impact factor: 5.315

3.  What is the preferred strength setting of the sinogram-affirmed iterative reconstruction algorithm in abdominal CT imaging?

Authors:  Andrew D Hardie; Rachel M Nelson; Robert Egbert; William J Rieter; Sameer V Tipnis
Journal:  Radiol Phys Technol       Date:  2014-08-28

4.  Sinogram Affirmed Iterative Reconstruction (SAFIRE) versus weighted filtered back projection (WFBP) effects on quantitative measure in the COPDGene 2 test object.

Authors:  J P Sieren; E A Hoffman; M K Fuld; K S Chan; J Guo; J D Newell
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

5.  Dose reduction potential of iterative reconstruction algorithms in neck CTA-a simulation study.

Authors:  Stephan Ellmann; Ferdinand Kammerer; Thomas Allmendinger; Michael Brand; Rolf Janka; Matthias Hammon; Michael M Lell; Michael Uder; Manuel Kramer
Journal:  Dentomaxillofac Radiol       Date:  2016-08-19       Impact factor: 2.419

6.  A phantom study for ground-glass nodule detectability using chest digital tomosynthesis with iterative reconstruction algorithm by ten observers: association with radiation dose and nodular characteristics.

Authors:  Katsunori Miyata; Yukihiro Nagatani; Mitsuru Ikeda; Masashi Takahashi; Norihisa Nitta; Satoru Matsuo; Shinichi Ohta; Hideji Otani; Ayumi Nitta-Seko; Yoko Murakami; Keiko Tsuchiya; Akitoshi Inoue; Sayaka Misaki; Khishigdorj Erdenee; Tetsuo Kida; Kiyoshi Murata
Journal:  Br J Radiol       Date:  2017-02-17       Impact factor: 3.039

7.  Estimating subjective evaluation of low-contrast resolution using convolutional neural networks.

Authors:  Yujiro Doi; Atsushi Teramoto; Ayumi Yamada; Masanao Kobayashi; Kuniaki Saito; Hiroshi Fujita
Journal:  Phys Eng Sci Med       Date:  2021-10-11

8.  The Impact of Different Levels of Adaptive Iterative Dose Reduction 3D on Image Quality of 320-Row Coronary CT Angiography: A Clinical Trial.

Authors:  Sarah Feger; Matthias Rief; Elke Zimmermann; Peter Martus; Joanne Désirée Schuijf; Jörg Blobel; Felicitas Richter; Marc Dewey
Journal:  PLoS One       Date:  2015-05-06       Impact factor: 3.240

9.  Image quality at low tube voltage (70 kV) and sinogram-affirmed iterative reconstruction for computed tomography in infants with congenital heart disease.

Authors:  Motoo Nakagawa; Yoshiyuki Ozawa; Keita Sakurai; Masashi Shimohira; Kazuya Ohashi; Miki Asano; Sachiko Yamaguchi; Yuta Shibamoto
Journal:  Pediatr Radiol       Date:  2015-06-27

10.  Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality.

Authors:  Peijie Lv; Jie Liu; Rui Zhang; Yan Jia; Jianbo Gao
Journal:  Korean J Radiol       Date:  2015-05-13       Impact factor: 3.500

View more