Fluid-structure interactions in micro-interlocked regions of the cement-bone interface.

Kenneth A Mann1, Mark A Miller.   

Abstract

Experimental tests and computational modelling were used to explore the fluid dynamics at the trabeculae-cement interlock regions found in the tibial component of total knee replacements. A cement-bone construct of the proximal tibia was created to simulate the immediate post-operative condition. Gap distributions along nine trabeculae-cement regions ranged from 0 to 50.4 μm (mean = 12 μm). Micro-motions ranged from 0.56 to 4.7 μm with a 1 MPa compressive load to the cement. Fluid-structure analysis between the trabeculae and the cement used idealised models with parametric evaluation of loading direction, gap closing fraction (GCF), gap thickness, loading frequency and fluid viscosity. The highest fluid shear stresses (926 Pa) along the trabecular surface were found for conditions with very thin and large GCFs, much larger than reported physiological levels (~1-5 Pa). A second fluid-structure model was created with a provision for bone resorption using a constitutive model with resorption velocity proportional to fluid shear rate. A lower cut-off was used, below which bone resorption would not occur (50 s(-1)). Results showed that there was initially high shear rates (>1000 s(-1)) that diminished after initial trabecular resorption. Resorption continued in high shear rate regions, resulting in a final shape with bone left deep in the cement layer, and is consistent with morphology found in post-mortem retrievals. Small gaps between the trabecular surface and the cement in the immediate post-operative state produce fluid flow conditions that appear to be supra-physiologic; these may cause fluid-induced lysis of trabeculae in the micro-interlock regions.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23480611      PMCID: PMC3686830          DOI: 10.1080/10255842.2013.767336

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  30 in total

1.  Mechanisms for pumping fluid through cementless acetabular components with holes.

Authors:  William L Walter; Jonathan Clabeaux; Timothy M Wright; William Walsh; William K Walter; Thomas P Sculco
Journal:  J Arthroplasty       Date:  2005-12       Impact factor: 4.757

2.  A controlled experimental model of revision implants: Part II. Implementation with loaded titanium implants and bone graft.

Authors:  J E Bechtold; O Mouzin; L Kidder; K Søballe
Journal:  Acta Orthop Scand       Date:  2001-12

3.  Short periods of oscillating fluid pressure directed at a titanium-bone interface in rabbits lead to bone lysis.

Authors:  H van der Vis; P Aspenberg; R de Kleine; W Tigchelaar; C J van Noorden
Journal:  Acta Orthop Scand       Date:  1998-02

4.  High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

Authors:  Mark J Conroy; Annaïg Pédrono; Joan E Bechtold; Kjeld Søballe; Dominique Ambard; Pascal Swider
Journal:  Magn Reson Imaging       Date:  2006-02-13       Impact factor: 2.546

5.  Influence of time in-situ and implant type on fixation strength of cemented tibial trays - a post mortem retrieval analysis.

Authors:  Anne Gebert de Uhlenbrock; Vesna Püschel; Klaus Püschel; Michael M Morlock; Nicholas E Bishop
Journal:  Clin Biomech (Bristol, Avon)       Date:  2012-07-20       Impact factor: 2.063

6.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002.

Authors:  Steven Kurtz; Fionna Mowat; Kevin Ong; Nathan Chan; Edmund Lau; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

7.  Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses.

Authors:  L Ryd; B E Albrektsson; L Carlsson; F Dansgård; P Herberts; A Lindstrand; L Regnér; S Toksvig-Larsen
Journal:  J Bone Joint Surg Br       Date:  1995-05

8.  Synergistic effect of particles and cyclic pressure on cytokine production in human monocyte/macrophages: proposed role in periprosthetic osteolysis.

Authors:  A McEvoy; M Jeyam; G Ferrier; C E Evans; J G Andrew
Journal:  Bone       Date:  2002-01       Impact factor: 4.398

9.  Thermal analysis of bone cement polymerisation at the cement-bone interface.

Authors:  M Stańczyk; B van Rietbergen
Journal:  J Biomech       Date:  2004-12       Impact factor: 2.712

10.  Loosening of the cemented hip prosthesis. The importance of heat injury.

Authors:  B Mjöberg
Journal:  Acta Orthop Scand Suppl       Date:  1986
View more
  14 in total

1.  Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties.

Authors:  Mark A Miller; Jacklyn R Goodheart; Timothy H Izant; Clare M Rimnac; Richard J Cleary; Kenneth A Mann
Journal:  Clin Orthop Relat Res       Date:  2013-08-24       Impact factor: 4.176

2.  GSK-3β inhibition suppresses instability-induced osteolysis by a dual action on osteoblast and osteoclast differentiation.

Authors:  Mehdi Amirhosseini; Rune V Madsen; K Jane Escott; Mathias P Bostrom; F Patrick Ross; Anna Fahlgren
Journal:  J Cell Physiol       Date:  2017-09-28       Impact factor: 6.384

3.  Similitude of cement-bone micromechanics in cemented rat and human knee replacement.

Authors:  Kenneth A Mann; Mark A Miller; Megan E Tatusko; Megan E Oest
Journal:  J Orthop Res       Date:  2020-03-20       Impact factor: 3.494

4.  Strain shielding in trabecular bone at the tibial cement-bone interface.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Mech Behav Biomed Mater       Date:  2016-11-10

5.  Trabecular resorption patterns of cement-bone interlock regions in total knee replacements.

Authors:  Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Kenneth A Mann
Journal:  J Orthop Res       Date:  2017-05-15       Impact factor: 3.494

6.  In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties.

Authors:  Jacklyn R Goodheart; Mark A Miller; Kenneth A Mann
Journal:  J Orthop Res       Date:  2014-04-29       Impact factor: 3.494

Review 7.  [Endoprostheses in the elderly : Biomaterials, implant selection and fixation technique].

Authors:  M M Morlock; M Jäger
Journal:  Orthopade       Date:  2017-01       Impact factor: 1.087

8.  Changes in microgaps, micromotion, and trabecular strain from interlocked cement-trabecular bone interfaces in total knee replacements with in vivo service.

Authors:  Mark A Miller; Jacklyn R Goodheart; Benjamin Khechen; Dennis Janssen; Kenneth A Mann
Journal:  J Orthop Res       Date:  2015-12-10       Impact factor: 3.494

Review 9.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

10.  Experimental and computational micromechanics at the tibial cement-trabeculae interface.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Biomech       Date:  2016-04-02       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.