Literature DB >> 7744919

Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses.

L Ryd1, B E Albrektsson, L Carlsson, F Dansgård, P Herberts, A Lindstrand, L Regnér, S Toksvig-Larsen.   

Abstract

The tibial components in 143 patients with total knee replacements performed before 1988 were assessed for micromotion using roentgen stereophotogrammetric analysis (RSA) over a period of 13 years. The fixation of the prostheses remained clinically sound in all cases, although revision had been required for other reasons in seven. In a second group taken from all cases with RSA available on our full database to 1990, 15 tibial components had been followed by RSA from the insertion until, 1 to 11 years after the initial arthroplasty, they were revised for mechanical loosening of the tibial component; 12 of these comprised all the loosenings in the base group, thus making a total of 155 consecutive cases, while an additional three were inserted after the base material had been compiled. The mean migration in the first group was about 1 mm at one year, but subsequent migration was slower, reaching a mean of about 1.5 mm after ten years. About one-third migrated continuously throughout follow-up, while two-thirds ceased to migrate after one to two years. In the revision group, 14 components had migrated continuously and at one year significantly more than those in the first group. One revision case lacked the crucial one-year follow-up and could not be classified. These findings suggest that mechanical loosening begins early in the postoperative period. Clinical symptoms which necessitate revision, seen at this stage in 20% of abnormally migrating tibial components, may not appear until up to ten years after the operation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7744919

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  130 in total

Review 1.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

Review 2.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

3.  Early migration of the cemented tibial component of unicompartmental knee arthroplasty: a radiostereometry study.

Authors:  Andrea Ensini; Paolo Barbadoro; Alberto Leardini; Fabio Catani; Sandro Giannini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-04       Impact factor: 4.342

4.  Level of constraint in revision knee arthroplasty.

Authors:  Pier Francesco Indelli; Nick Giori; William Maloney
Journal:  Curr Rev Musculoskelet Med       Date:  2015-12

5.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

6.  Topical bisphosphonate augments fixation of bone-grafted hydroxyapatite coated implants, BMP-2 causes resorption-based decrease in bone.

Authors:  Jorgen Baas; Marianne Vestermark; Thomas Jensen; Joan Bechtold; Kjeld Soballe; Thomas Jakobsen
Journal:  Bone       Date:  2017-01-07       Impact factor: 4.398

7.  Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening.

Authors:  Shuo Liu; Amarjit S Virdi; Kotaro Sena; W Frank Hughes; Dale R Sumner
Journal:  J Biomed Mater Res A       Date:  2012-01-24       Impact factor: 4.396

8.  Comparison of cementing techniques of the tibial component in total knee replacement.

Authors:  Tuuli Saari; Ming Guo Li; David Wood; Bo Nivbrant
Journal:  Int Orthop       Date:  2008-08-15       Impact factor: 3.075

9.  Randomised clinical trial assessing migration of uncemented primary total hip replacement stems, with and without autologous impaction bone grafting.

Authors:  Michael Rutherford; Riaz J K Khan; Daniel P Fick; Samantha Haebich; Oscar Nivbrant; Thomas Kozak
Journal:  Int Orthop       Date:  2019-01-31       Impact factor: 3.075

10.  Assessment of modified gold surfaced titanium implants on skeletal fixation.

Authors:  Kasra Zainali; Gorm Danscher; Thomas Jakobsen; Jorgen Baas; Per Møller; Joan E Bechtold; Kjeld Soballe
Journal:  J Biomed Mater Res A       Date:  2012-07-30       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.