Literature DB >> 23478893

Shortened acquisition time or reduced-activity dose for gated myocardial perfusion SPECT with new reconstruction algorithm.

Xiao-Xin Sun1, Yue-Qin Tian, Dao-Yu Wang, Zuo-Xiang He.   

Abstract

To confirm that shortened acquisition time or reduced-activity dose in single-photon emission computed tomography (SPECT) myocardial perfusion imaging reconstructed with Astonish software (AS) does not compromise image quality or diagnostic accuracy. One hundred patients referred for SPECT myocardial perfusion imaging were prospectively studied. The patients were randomly selected to receive the full-dose protocol (group A, n = 54) or the half-dose protocol (group B, n = 46). The patients of group A underwent a 2-day stress/rest protocol. After half-time acquisition, they underwent a full-time acquisition for stress and rest SPECT. Group B underwent a 1-day stress/rest protocol. During peak stress, all patients received an intravenous injection of (99m)Tc-methoxyisobutylisonitrile (MIBI; 5.2 ± 0.6 mCi). After the full-time stress acquisition, the patients underwent a double-time stress acquisition. If the stress image showed a defect, a patient received (99m)Tc-MIBI (19.5 ± 1.7 mCi) at rest on the same day. The rest SPECT acquisition protocol was the same in both groups. The low count (LC) and high count (HC) were acquired for each patient. AS and filtered back projection (FBP) reconstructed each set of raw data. Image quality of perfusion was assessed on a four-point scale. Perfusion parameters and function parameters were calculated by quantitative perfusion SPECT and quantitative gated SPECT. Mean image quality for LC-AS and HC-AS (3.5 ± 0.5 and 3.7 ± 0.5, respectively) was superior to HC-FBP (3.1 ± 0.4) in group A (for all, p < 0.001). LC-AS and HC-AS (3.5 ± 0.5 and 3.6 ± 0.5, respectively) in group B were superior to HC-FBP (3.1 ± 0.3) (for all, p < 0.001). LC-AS, HC-AS and LC-FBP showed high diagnostic concordance with HC-FBP (kappa value was 0.92, 0.92, and 0.94, respectively; all p < 0.001). Cardiac SPECT studies can be acquired with half of the scan time or reduced radioactivity dose and reconstructed by using the AS algorithm without compromising image quality.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23478893     DOI: 10.1007/s10554-013-0205-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  18 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Warren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Circulation       Date:  2002-01-29       Impact factor: 29.690

2.  Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography.

Authors:  W Lane Duvall; Joseph M Sweeny; Lori B Croft; Eric Ginsberg; Krista A Guma; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2011-12-07       Impact factor: 5.952

3.  Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies.

Authors:  Salvador Borges-Neto; Robert A Pagnanelli; Linda K Shaw; Emily Honeycutt; Shuli C Shwartz; George L Adams; Ralph Edward Coleman
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

4.  A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Anna Leykekhman; Linda B Thompson; Marvin Friedman
Journal:  J Nucl Cardiol       Date:  2011-02-02       Impact factor: 5.952

Review 5.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

6.  High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results.

Authors:  Alessia Gimelli; Matteo Bottai; Dario Genovesi; Assuero Giorgetti; Fabio Di Martino; Paolo Marzullo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-09-02       Impact factor: 9.236

7.  Ordered subset expectation maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" filtered backprojection.

Authors:  E Gordon DePuey; Ramesh Gadiraju; John Clark; Linda Thompson; Frank Anstett; Shuli C Shwartz
Journal:  J Nucl Cardiol       Date:  2008-04-24       Impact factor: 5.952

8.  High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.

Authors:  Tali Sharir; Simona Ben-Haim; Konstantine Merzon; Vitali Prochorov; Dalia Dickman; Shlomo Ben-Haim; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2008-03

9.  Exposure to low-dose ionizing radiation from medical imaging procedures.

Authors:  Reza Fazel; Harlan M Krumholz; Yongfei Wang; Joseph S Ross; Jersey Chen; Henry H Ting; Nilay D Shah; Khurram Nasir; Andrew J Einstein; Brahmajee K Nallamothu
Journal:  N Engl J Med       Date:  2009-08-27       Impact factor: 91.245

10.  Wide beam reconstruction "quarter-time" gated myocardial perfusion SPECT functional imaging: a comparison to "full-time" ordered subset expectation maximum.

Authors:  E Gordon DePuey; Srinivas Bommireddipalli; John Clark; Linda Thompson; Yossi Srour
Journal:  J Nucl Cardiol       Date:  2009-06-17       Impact factor: 5.952

View more
  5 in total

1.  Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients.

Authors:  M Lecchi; I Martinelli; O Zoccarato; C Maioli; Giovanni Lucignani; A Del Sole
Journal:  J Nucl Cardiol       Date:  2016-02-24       Impact factor: 5.952

2.  Advances in image reconstruction software in nuclear cardiology: Is all that glitters gold?

Authors:  Claudio Marcassa; Orazio Zoccarato
Journal:  J Nucl Cardiol       Date:  2016-05-24       Impact factor: 5.952

3.  Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan.

Authors:  Takayuki Shibutani; Koichi Okuda; Hajime Ichikawa; Toyohiro Kato; Kenta Miwa; Hiroyuki Tsushima; Masahisa Onoguchi; Akio Nagaki
Journal:  Jpn J Radiol       Date:  2020-01-09       Impact factor: 2.374

4.  Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT.

Authors:  Norikazu Matsutomo; Akio Nagaki; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2014

5.  Optimization of 99m Tc whole-body SPECT/CT image quality: A phantom study.

Authors:  Mansour M Alqahtani; Kathy P Willowson; Chris Constable; Roger Fulton; Peter L Kench
Journal:  J Appl Clin Med Phys       Date:  2022-01-20       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.