Literature DB >> 31919636

Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan.

Takayuki Shibutani1, Koichi Okuda2, Hajime Ichikawa3, Toyohiro Kato3, Kenta Miwa4, Hiroyuki Tsushima5, Masahisa Onoguchi6, Akio Nagaki7.   

Abstract

AIM: Recently, nuclear cardiology has dramatically advanced by a new technology development such as the device, short-term acquisition system, image reconstruction algorithm and image analysis. Although these innovations have been gradually employed in routine examinations, we did not investigate the current use of image acquisition, image reconstruction, and image analysis with myocardial perfusion single-photon emission computed tomography (MPS). We investigated the current status of MPS imaging technology in Japan.
METHODS: We carried out a survey using a Web-based questionnaire system, the opening of which was announced via e-mail, and it was available on a website for 3 months. We collected data on the current use of MPS with 201Tl and/or 99mTc agents with respect to routine protocols, image acquisition, image reconstruction, and image analysis.
RESULTS: We received responses to the Web-based questionnaire from 178 and 174 people for 99mTc and 201Tl MPS, respectively. The routine protocols of MPS of stress-rest and rest-stress MPS on 1-day protocols with 99mTc were 41.2% and 14.5%, respectively, and the rest-only scan response rate was 23.7%, whereas that of 201Tl MPS was 65.9% with stress-rest MPS, 19.0% with rest-only MPS, and 10.9% with stress-rest MPS adding a rest scan 24 h after injection. The filtered back projection (FBP) method is most commonly used image reconstruction method, yielding 70.5% for 99mTc MPS and 76.8% for 201Tl MPS, including combined FBP and ordered subset expectation maximization method. The results for no-correction (NC) images were 49.2% with 99mTc MPS and 55.2% with 201Tl MPS including the response of NC and combined attenuation correction (AC) and scatter correction (SC) (i.e., ACSC) images. The AC or ACSC images of 99mTc and 201Tl were provided by 30-40% of the institutions surveyed.
CONCLUSIONS: We investigated the current status of MPS imaging technology in Japan, and found that although the use of various technical developments has been reported, some of these technologies have not been utilized effectively. Hence, we expect that nuclear medicine technology will be used more effectively to improve diagnosis.

Entities:  

Keywords:  Japan; Myocardial perfusion SPECT; Nuclear cardiology technology; Questionnaire; Survey

Year:  2020        PMID: 31919636     DOI: 10.1007/s11604-019-00915-2

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  45 in total

1.  Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT.

Authors:  Y Ohyama; S Tomiguchi; T Kira; M Kira; A Tsuji; A Koi; M Matsumoto; M Takahashi; Y Inobe; H Yasue
Journal:  Ann Nucl Med       Date:  2001-02       Impact factor: 2.668

2.  Clinical usefulness of attenuation and scatter correction in Tl-201 SPECT studies using coronary angiography as a reference.

Authors:  Antigoni Velidaki; Kostas Perisinakis; Sophia Koukouraki; John Koutsikos; Panos Vardas; Nicolaos Karkavitsas
Journal:  Hellenic J Cardiol       Date:  2007 Jul-Aug

3.  Comparison Between Prone and Upright Imaging of the Inferior Wall Using 201TlCl Myocardial Perfusion SPECT.

Authors:  Koji Nakaya; Masahisa Onoguchi; Yoshihiro Nishimura; Keisuke Kiso; Hideki Otsuka; Yoshifumi Nouno; Takayuki Shibutani; Eisuke Yasuda
Journal:  J Nucl Med Technol       Date:  2017-10-17

4.  99mTc-sestamibi can improve the inferior attenuation of TL-201 myocardial spect imaging.

Authors:  S J Wang; Y T Chen; C L Hwang; M S Lin; C H Kao; S H Yeh
Journal:  Int J Card Imaging       Date:  1993-06

5.  Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT.

Authors:  Jonathan M Links; E Gordon DePuey; Raymond Taillefer; Lewis C Becker
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

6.  Clinical impact of arrhythmias on gated SPECT cardiac myocardial perfusion and function assessment.

Authors:  K Nichols; S S Yao; M Kamran; T L Faber; C D Cooke; E G DePuey
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

7.  Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.

Authors:  Rene Nkoulou; Tobias A Fuchs; Aju P Pazhenkottil; Silke M Kuest; Jelena R Ghadri; Julia Stehli; Michael Fiechter; Bernhard A Herzog; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2016-06-30       Impact factor: 10.057

8.  Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine Working Group.

Authors:  Kenichi Nakajima; Shinichiro Kumita; Yoshio Ishida; Mitsuru Momose; Jun Hashimoto; Koichi Morita; Junichi Taki; Shohei Yamashina; Hirotaka Maruno; Masami Ogawa; Masahiro Kubota; Munehiro Takahashi; Tetsuro Odagawa; Koichi Yokozuka
Journal:  Ann Nucl Med       Date:  2007-11-26       Impact factor: 2.668

9.  Diffuse slow washout of myocardial thallium-201: a new scintigraphic indicator of extensive coronary artery disease.

Authors:  T M Bateman; J Maddahi; R J Gray; F L Murphy; E V Garcia; C M Conklin; M J Raymond; M E Stewart; H J Swan; D S Berman
Journal:  J Am Coll Cardiol       Date:  1984-07       Impact factor: 24.094

10.  Diagnostic performance of fusion of myocardial perfusion imaging (MPI) and computed tomography coronary angiography.

Authors:  Cesar A Santana; Ernest V Garcia; Tracy L Faber; Gopi K R Sirineni; Fabio P Esteves; Rupan Sanyal; Raghuveer Halkar; Mario Ornelas; Liudmila Verdes; Stamatios Lerakis; Julie J Ramos; Santiago Aguadé-Bruix; Hugo Cuéllar; Jaume Candell-Riera; Paolo Raggi
Journal:  J Nucl Cardiol       Date:  2009-01-22       Impact factor: 5.952