Literature DB >> 11916775

The feasibility of transesophageal echocardiograph-guided right and left ventricular oximetry in hemodynamically stable patients undergoing coronary artery bypass grafting.

J Margreiter1, C Keller, J Brimacombe.   

Abstract

UNLABELLED: There are no techniques available for continuous noninvasive measurement of the oxygen saturation of blood flowing through the heart. We assessed the feasibility and accuracy of transesophageal echocardiograph (TEE)-guided left ventricular (SpO2 LV) and right ventricular (SpO2 RV) oximetry. Twenty hemodynamically stable, well-oxygenated anesthetized patients (ASA physical status III, aged 51-75 yr) undergoing coronary artery bypass grafting were studied. A TEE probe was modified by attaching a single-use pediatric reflectance pulse oximeter just proximal to the ultrasound transducer. The TEE probe was directed toward the LV by using the transgastric mid-short axis view or toward the RV by using the transgastric RV inflow view, in random order. Readings were taken every 30 s for 10 min during a hemodynamically stable period of anesthesia. Simultaneous blood samples were taken from the radial artery and pulmonary artery to determine arterial oxygen saturation (SaO2) and mixed venous oxygen saturation (SvO2), respectively. During SpO2 LV readings, simultaneous finger pulse oximetry (SpO2 finger) was also recorded. SpO2 LV was feasible in 20 of 20 patients, and SpO2 RV was feasible in 19 of 20 patients. The mean +/- SD (range) oxygen saturation for each method was the following: SpO2 LV, 98.7% +/- 0.6% (97%-100%); SaO2, 98.7% +/- 0.6% (96.6%-99.4%); SpO2 finger, 98.1% +/- 1.2% (97%-100%); SpO2 RV, 73.9% +/- 4.7% (64%-85%); and SvO2, 74.5% +/- 4.4% (66.8%-82.6%). SpO2 LV agreed closely with SaO2 (mean difference, 0.072%). SpO2 RV agreed closely with SvO2 (mean difference, 0.65%). SpO2 LV agreed more closely with SaO2 than finger oximetry (mean difference, -0.072 vs -0.692). TEE-guided SpO2 LV and SpO2 RV are feasible in hemodynamically stable anesthetized patients and provide similar readings to arterial and mixed venous blood samples. The technique merits further investigation. IMPLICATIONS: Transesophageal echocardiograph-guided left and right ventricular oximetry is feasible in hemodynamically stable anesthetized patients and provides similar readings to arterial and mixed venous blood samples.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11916775     DOI: 10.1097/00000539-200204000-00005

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Can the descending aortic stroke volume be estimated by transesophageal descending aortic photoplethysmography?

Authors:  Peng Ling; Gong Quan; Yu Siyuan; Gao Bo; Wei Wei
Journal:  J Anesth       Date:  2017-03-27       Impact factor: 2.078

2.  Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia.

Authors:  Guo Chen; Zhaoqiong Zhu; Jin Liu; Wei Wei
Journal:  Front Med       Date:  2012-10-02       Impact factor: 4.592

3.  A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry.

Authors:  Li Wang; Wei Wei; Ming Gong; Ling Mu
Journal:  J Clin Monit Comput       Date:  2010-03-12       Impact factor: 2.502

4.  The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Authors:  Ling Mou; Quan Gong; Wei Wei; Bo Gao
Journal:  J Clin Monit Comput       Date:  2013-03-10       Impact factor: 2.502

5.  A preliminary study on the monitoring of mixed venous oxygen saturation through the left main bronchus.

Authors:  Xiang-rui Wang; Yong-jun Zheng; Jie Tian; Zheng-hong Wang; Zhi-ying Pan
Journal:  Crit Care       Date:  2006-02       Impact factor: 9.097