Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance.

Rein Raamat1, Kersti Jagomägi, Jaak Talts.   

Abstract

Digital pulse volume and arterial compliance have been estimated by using the finger arterial pressure and volume waveforms when performing measurements at rest and during local cold exposure in 17 volunteers. The amplitude-based algorithm determines compliance as a ratio of finger volume and pressure pulses. Cooling was conducted by immersion of the contra-lateral arm in water at 11 degrees C for 2 min. Continuous non-invasive finger blood pressure was measured by the Finapres monitor, while the finger volume pulses were recorded by the UT9201 physiograph, which provides a photoplethysmographic registration of volume changes in a large range of transmural pressures (P(transm)). The photoplethysmographic signal was calibrated by applying a graded modulation to the cuff. The study demonstrated that contra-lateral arm cooling induced a statistically significant (P<0.001) reduction in the digital arterial compliance at P(transm) approximately 0 as well as at P(transm) = 50 mmHg. The median compliance diminished during cooling from 0.67 mm(3 )mmHg(-1) to the level of 55% at P(transm) approximately 0, and from 0.14 mm(3 )mmHg(-1) to the level of 42% at P(transm) = 50 mmHg respectively. The observed changes were mostly due to the reduction in the pulse volume. Digital arterial pressure and volume waveforms recorded by the Finapres monitor combined with a calibrated photoplethysmograph can be used in estimating the absolute values of the dynamic compliance of finger arteries. A quantitative estimation instead of the non-calibrated recording of the digital pulse volume allows shortening the variability and widening the scope of finger arterial compliance measurements.

Mesh:

Year:  2007        PMID: 17944657     DOI: 10.1111/j.1475-097X.2007.00759.x

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  3 in total

1.  The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources.

Authors:  Ling Mou; Quan Gong; Wei Wei; Bo Gao
Journal:  J Clin Monit Comput       Date:  2013-03-10       Impact factor: 2.502

2.  New insights into the origin of remote PPG signals in visible light and infrared.

Authors:  Andreia V Moço; Sander Stuijk; Gerard de Haan
Journal:  Sci Rep       Date:  2018-05-31       Impact factor: 4.379

Review 3.  Diagnostic Features and Potential Applications of PPG Signal in Healthcare: A Systematic Review.

Authors:  Malak Abdullah Almarshad; Md Saiful Islam; Saad Al-Ahmadi; Ahmed S BaHammam
Journal:  Healthcare (Basel)       Date:  2022-03-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.