Literature DB >> 23456358

Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.

Rodolfo Staico1, Marco A Costa, Daniel Chamié, Hiram Bezerra, Luciana V Armaganijan, Ricardo A Costa, José Ribamar Costa, Dimytri Siqueira, Marinella Centemero, Áurea Chaves, Luiz Fernando Tanajura, Alexandre Abizaid, Fausto Feres, J Eduardo M R Sousa, Amanda G M R Sousa.   

Abstract

First generation drug-eluting stents (DES) are associated with reduced in-stent restenosis but significant increased risk of very late stent thrombosis (VLST). The absence of polymer in DES systems may reduce the occurrence of VLST. Optic coherence tomography (OCT) has been used for stent analysis as a surrogate safety endpoint. This study aimed to assess the long-term follow up of strut apposition and tissue coverage of BioMatrix DES by OCT. 20 patients undergoing BioMatrix DES (n = 15) or S-Stent BMS (n = 5) implantation were followed for at least 5 years and evaluated by quantitative coronary angiography, intravascular ultrasound, and OCT. The difference between the stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by Fisher exact test. Rates of in-stent late loss were similar between groups [0.40 (0.21;0.77) vs. 0.68 (0.66; 0.82) mm, p = 0.205, for BioMatrix and S-Stent, respectively]. The vessel, stent and lumen volumes did not differ between groups. Patients treated with BioMatrix had significantly less stent obstruction [5.6 (4.4;9.7) vs. 28.6 (24.7;29.0) %, p = 0.001]. OCT analysis of 12 stents (Biomatrix = 9 and S-Stent = 3) demonstrated 126 (8.7 %) uncovered struts in the BioMatrix group compared to 23 (4.0 %) in the S-Stent group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6 %) struts in the DES and 2 (0.4 %) struts in the BMS groups were simultaneously uncovered and malapposed (p = 0.924). BioMatrix DES was associated with lower rates of in-stent obstruction, and similar percentage of neointimal coverage on struts and of complete strut apposition.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23456358     DOI: 10.1007/s10554-013-0188-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  27 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

Review 2.  Coronary-artery stents.

Authors:  Patrick W Serruys; Michael J B Kutryk; Andrew T L Ong
Journal:  N Engl J Med       Date:  2006-02-02       Impact factor: 91.245

Review 3.  Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern.

Authors:  Edoardo Camenzind; P Gabriel Steg; William Wijns
Journal:  Circulation       Date:  2007-03-07       Impact factor: 29.690

4.  Long-term follow-up of neointimal coverage of sirolimus-eluting stents--evaluation with optical coherence tomography.

Authors:  Ken-ichi Ishigami; Shiro Uemura; Yoshinobu Morikawa; Tsunenari Soeda; Satoshi Okayama; Taku Nishida; Yasuhiro Takemoto; Kenji Onoue; Satoshi Somekawa; Yukiji Takeda; Hiroyuki Kawata; Manabu Horii; Yoshihiko Saito
Journal:  Circ J       Date:  2009-09-29       Impact factor: 2.993

5.  Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation.

Authors:  Davide Capodanno; Francesco Prati; Tomasz Pawlowsky; Maria Cera; Alessio La Manna; Mario Albertucci; Corrado Tamburino
Journal:  EuroIntervention       Date:  2009-11       Impact factor: 6.534

6.  Serial angiographic and intravascular ultrasound evaluation to interrogate the presence of late "catch-up" phenomenon after Cypher® sirolimus-eluting stent implantation.

Authors:  Daniel Chamié; Alexandre Abizaid; J Ribamar Costa; Fausto Feres; J Fábio Almiro da Silva; Luiz Alberto P Mattos; Rodolfo Staico; Ricardo A Costa; Andréa Abizaid; Luiz Fernando L Tanajura; Amanda G M R Sousa; J Eduardo Sousa
Journal:  Int J Cardiovasc Imaging       Date:  2010-11-17       Impact factor: 2.357

7.  Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden.

Authors:  Bo Lagerqvist; Stefan K James; Ulf Stenestrand; Johan Lindbäck; Tage Nilsson; Lars Wallentin
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

8.  Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents.

Authors:  Adnan Kastrati; Julinda Mehilli; Jürgen Pache; Christoph Kaiser; Marco Valgimigli; Henning Kelbaek; Maurizio Menichelli; Manel Sabaté; Maarten J Suttorp; Dietrich Baumgart; Melchior Seyfarth; Matthias E Pfisterer; Albert Schömig
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

9.  A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

Authors:  Gregg W Stone; Stephen G Ellis; David A Cox; James Hermiller; Charles O'Shaughnessy; James Tift Mann; Mark Turco; Ronald Caputo; Patrick Bergin; Joel Greenberg; Jeffrey J Popma; Mary E Russell
Journal:  N Engl J Med       Date:  2004-01-15       Impact factor: 91.245

Review 10.  Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting.

Authors:  Giulio Guagliumi; Vasile Sirbu
Journal:  Catheter Cardiovasc Interv       Date:  2008-08-01       Impact factor: 2.692

View more
  2 in total

Review 1.  Cardiovascular imaging 2013 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2014-04       Impact factor: 2.357

Review 2.  Management of CAD in Patients with Active Cancer: the Interventional Cardiologists' Perspective.

Authors:  Dana Elena Giza; Kostas Marmagkiolis; Elie Mouhayar; Jean-Bernard Durand; Cezar Iliescu
Journal:  Curr Cardiol Rep       Date:  2017-06       Impact factor: 2.931

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.