Literature DB >> 19789417

Long-term follow-up of neointimal coverage of sirolimus-eluting stents--evaluation with optical coherence tomography.

Ken-ichi Ishigami1, Shiro Uemura, Yoshinobu Morikawa, Tsunenari Soeda, Satoshi Okayama, Taku Nishida, Yasuhiro Takemoto, Kenji Onoue, Satoshi Somekawa, Yukiji Takeda, Hiroyuki Kawata, Manabu Horii, Yoshihiko Saito.   

Abstract

BACKGROUND: Late stent thrombosis related to delayed neointimal growth is a major concern after drug-eluting stent (DES) implantation. The time course of neointimal growth and risk factors of uncovered stent struts after sirolimus-eluting stent (SES) was studied using optical coherence tomography (OCT). METHODS AND
RESULTS: The 60 patients were enrolled and classified into G1 (follow-up period <9 months, n=27), G2 (9-24 months, n=18), and G3 (>25 months, n=15). The time elapsed since SES implantation was associated with a significant increase in mean neointimal area and neointimal thickness, and also with a significant decrease in the number of uncovered stent struts (G1: 14.8%, G2: 11.7%, and G3: 4.1%, P<0.001). However, only 17.6% of implanted SES was completely covered by neointima, even in the G3 period. Small-diameter SES, complex coronary lesions with lipid and calcium content adjacent to stent struts, and diabetes predicted delayed neointimal coverage of SES struts in G1.
CONCLUSIONS: Neointima inside SES progressively increases after the routine follow-up period, but only a few SES were completely covered at 3 years after implantation. OCT is a useful modality for assessing neointimal formation after SES implantation, and may give important information about the strategy of antiplatelet therapy after DES implantation.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19789417     DOI: 10.1253/circj.cj-08-1116

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  11 in total

1.  Comparison of the performance of zotarolimus- and everolimus-eluting stents by optical coherence tomography and coronary angioscopy.

Authors:  Taito Masawa; Shichiro Abe; Shigeru Toyoda; Masashi Sakuma; Takahisa Nasuno; Michiya Kageyama; Michiaki Tokura; Satoshi Koizumi; Isao Taguchi; Teruo Inoue
Journal:  Heart Vessels       Date:  2015-08-14       Impact factor: 2.037

2.  Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Jung-Sun Kim; Changmyung Oh; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2011-05-31       Impact factor: 2.357

3.  Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.

Authors:  Hirofumi Ohtani; Shigeki Kimura; Tomoyo Sugiyama; Keiichi Hishikari; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Hiroyuki Hikita; Takashi Ashikaga; Atsushi Takahashi; Mitsuaki Isobe
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

Review 4.  Assessment of coronary stent by optical coherence tomography, methodology and definitions.

Authors:  Emile Aziz Mehanna; Guilherme Ferragut Attizzani; Hiroyuki Kyono; Michael Hake; Hiram Grando Bezerra
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-19       Impact factor: 2.357

5.  Comparable neointimal healing in patients with stable coronary lesions and acute coronary syndrome: 3-month optical coherence tomography analysis.

Authors:  Yuma Hamanaka; Yohei Sotomi; Tomoaki Kobayashi; Takashi Omatsu; Jouke Dijkstra; Yasushi Sakata; Atsushi Hirayama; Akio Hirata; Yoshiharu Higuchi
Journal:  Int J Cardiovasc Imaging       Date:  2021-02-16       Impact factor: 2.357

Review 6.  Optical coherence tomography endpoints in stent clinical investigations: strut coverage.

Authors:  Satoko Tahara; Daniel Chamié; Motaz Baibars; Chadi Alraies; Marco Costa
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-11       Impact factor: 2.357

7.  Very long-term follow-up of strut apposition and tissue coverage with Biolimus A9 stents analyzed by optical coherence tomography.

Authors:  Rodolfo Staico; Marco A Costa; Daniel Chamié; Hiram Bezerra; Luciana V Armaganijan; Ricardo A Costa; José Ribamar Costa; Dimytri Siqueira; Marinella Centemero; Áurea Chaves; Luiz Fernando Tanajura; Alexandre Abizaid; Fausto Feres; J Eduardo M R Sousa; Amanda G M R Sousa
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

Review 8.  Optical coherence tomography: from research to practice.

Authors:  Juan Luis Gutiérrez-Chico; Eduardo Alegría-Barrero; Rodrigo Teijeiro-Mestre; Pak Hei Chan; Hiroto Tsujioka; Ranil de Silva; Nicola Viceconte; Alistair Lindsay; Tiffany Patterson; Nicolas Foin; Takashi Akasaka; Carlo di Mario
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-02-13       Impact factor: 6.875

9.  Impact of statin treatment on strut coverage after drug-eluting stent implantation.

Authors:  Yongsung Suh; Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Yonsei Med J       Date:  2015-01       Impact factor: 2.759

10.  Vascular Healing Response after Everolimus-Eluting Stent Implantation in Acute Coronary Syndrome Culprit Lesions: Comparison with Implantation in Stable Angina Pectoris.

Authors:  Yutaka Goryo; Teruyoshi Kume; Tomoya Ueda; Makoto Watanabe; Ryotaro Yamada; Yoji Neishi; Yoshihiko Saito; Shiro Uemura
Journal:  Acta Cardiol Sin       Date:  2018-03       Impact factor: 2.672

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.