The PENN-PET scanner consists of six hexagonally arranged position-sensitive Nal(TI) detectors. This design offers high spatial resolution in all three dimensions, high sampling density along all three axes without scanner motion, a large axial acceptance angle, good energy resolution, and good timing resolution. This results in three-dimensional imaging capability with high sensitivity and low scatter and random backgrounds. The spatial resolution is 5.5 mm (FWHM) in all directions near the center. The true sensitivity, for a brain-sized object, is a maximum of 85 kcps/microCi/ml and the scatter fraction is a minimum of 10%, both depending on the lower level energy threshold. The scanner can handle up to 5 mCi in the field of view, at which point the randoms equal the true coincidences and the detectors reach their count rate limit. We have so far acquired [18F]FDG brain studies and cardiac studies, which show the applicability of our scanner for both brain and whole-body imaging. With the results to date, we feel that this design results in a simple yet high performance scanner which is applicable to many types of static and dynamic clinical studies.

Mesh:

Year:  1990        PMID: 2341898

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  14 in total

1.  Application of a generalized scan statistic model to evaluate TOF PET images.

Authors:  Suleman Surti; Joel S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2011       Impact factor: 1.679

Review 2.  From PET detectors to PET scanners.

Authors:  John L Humm; Anatoly Rosenfeld; Alberto Del Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-02       Impact factor: 9.236

3.  Performance evaluation of the Philips MOSAIC small animal PET scanner.

Authors:  Marc C Huisman; Sybille Reder; Axel W Weber; Sibylle I Ziegler; Markus Schwaiger
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-11-22       Impact factor: 9.236

4.  Significant clinical impact and prognostic stratification provided by FDG-PET in the staging of oesophageal cancer.

Authors:  Cuong P Duong; Helen Demitriou; Leann Weih; Anne Thompson; David Williams; Robert J S Thomas; Rodney J Hicks
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-02-10       Impact factor: 9.236

5.  Optimization and assessment of quantitative 124I imaging on a Philips Gemini dual GS PET/CT system.

Authors:  Rebecca A Gregory; Claire A Hooker; Mike Partridge; Glenn D Flux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03-14       Impact factor: 9.236

Review 6.  Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose.

Authors:  P Rigo; P Paulus; B J Kaschten; R Hustinx; T Bury; G Jerusalem; T Benoit; J Foidart-Willems
Journal:  Eur J Nucl Med       Date:  1996-12

7.  Total Body PET: Why, How, What for?

Authors:  Suleman Surti; Austin R Pantel; Joel S Karp
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-04-03

Review 8.  Recent developments in PET detector technology.

Authors:  Tom K Lewellen
Journal:  Phys Med Biol       Date:  2008-08-11       Impact factor: 3.609

Review 9.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

10.  Regional cerebral glucose metabolism in late-life depression and Alzheimer disease: a preliminary positron emission tomography study.

Authors:  A Kumar; A Newberg; A Alavi; J Berlin; R Smith; M Reivich
Journal:  Proc Natl Acad Sci U S A       Date:  1993-08-01       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.