Literature DB >> 23400447

Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: a phantom study.

Ko Higuchi1, Michinobu Nagao, Yoshio Matsuo, Shunya Sunami, Takeshi Kamitani, Mikako Jinnouchi, Masato Yonezawa, Yuzo Yamasaki, Hidetake Yabuuchi, Masamitsu Hatkenaka, Hiroshi Honda.   

Abstract

The detection of ground-glass opacities (GGOs) is an important issue in lung cancer screening with low-dose CT. The iterative reconstruction (IR) technique has the ability to improve the image quality relative to the filtered back projection (FBP) technique with low-dose CT. Our purpose was to investigate the ability to detect GGO in a chest phantom using a low-dose CT and hybrid IR, named iDose. Simulated GGOs in a chest phantom were scanned with 256-section CT at tube current second products of 20, 50, 100, and 200 mAs. Five radiologists visually assessed the detectability of GGOs in the phantom. The contrast-to-noise ratio (CNR) for GGOs was used as an estimate of image quality. Comparison of the detectability and CNR between standard images with 200 mAs-FBP and low-dose images with 20, 50, and 100-mAs FBP/iDose were performed by ANOVA with Dunnett's and Tukey's test. The detectability was significantly lower at 20-mAs FBP/iDose and 50-mAs FBP than that at 200-mAs FBP (p < 0.05). There was no significant difference between 50-mAs iDose and 200-mAs FBP and between 100-mAs iDose/FBP and 200-mAs FBP. The CNR was significantly higher on iDose images than that on FBP images at each mAs value. The CNR at 200-mAs FBP was the same as that at 50-mAs iDose (CNR:1.8). The hybrid IR technique and low-dose CT imaging with 50 mAs enabled noise and to maintain the detectability for GGOs in a chest phantom that is equivalent to the reference acquisitions of 200 mAs with FBP.

Entities:  

Mesh:

Year:  2013        PMID: 23400447     DOI: 10.1007/s12194-013-0200-y

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  18 in total

1.  Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography.

Authors:  Jiro Sato; Masaaki Akahane; Sachiko Inano; Mariko Terasaki; Hiroyuki Akai; Masaki Katsura; Izuru Matsuda; Akira Kunimatsu; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2011-12-17       Impact factor: 2.374

2.  Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT.

Authors:  Peter B Noël; Alexander A Fingerle; Bernhard Renger; Daniela Münzel; Ernst J Rummeny; Martin Dobritz
Journal:  AJR Am J Roentgenol       Date:  2011-12       Impact factor: 3.959

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: experimental study using chest phantom.

Authors:  Hisanobu Koyama; Yoshiharu Ohno; Atsushi A Kono; Akiko Kusaka; Minoru Konishi; Masaru Yoshii; Kazuro Sugimura
Journal:  Eur J Radiol       Date:  2009-04-10       Impact factor: 3.528

5.  The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devices.

Authors:  Yoshihisa Muramatsu; Yukihiro Tsuda; Yoshimasa Nakamura; Mitsuru Kubo; Toshiyuki Takayama; Kouzou Hanai
Journal:  J Comput Assist Tomogr       Date:  2003 May-Jun       Impact factor: 1.826

Review 6.  State of the art: technologies for computed tomography dose reduction.

Authors:  Martin L D Gunn; Jennifer R Kohr
Journal:  Emerg Radiol       Date:  2009-11-20

Review 7.  Computed tomography--old ideas and new technology.

Authors:  Dominik Fleischmann; F Edward Boas
Journal:  Eur Radiol       Date:  2011-01-20       Impact factor: 5.315

8.  Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography.

Authors:  Yoshinori Funama; Katsuyuki Taguchi; Daisuke Utsunomiya; Seitaro Oda; Yumi Yanaga; Yasuyuki Yamashita; Kazuo Awai
Journal:  J Comput Assist Tomogr       Date:  2011 Jul-Aug       Impact factor: 1.826

9.  Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung.

Authors:  Michinobu Nagao; Kenya Murase; Yoshifumi Yasuhara; Junpei Ikezoe; Kenji Eguchi; Hiroshi Mogami; Koichi Mandai; Masao Nakata; Yumi Ooshiro
Journal:  Invest Radiol       Date:  2002-12       Impact factor: 6.016

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  5 in total

1.  Low-dose CT screening using hybrid iterative reconstruction: confidence ratings of diagnoses of simulated lesions other than lung cancer.

Authors:  N Sakai; H Yabuuchi; M Kondo; Y Matsuo; T Kamitani; M Nagao; M Jinnouchi; M Yonezawa; T Kojima; Y Yano; H Honda
Journal:  Br J Radiol       Date:  2015-07-08       Impact factor: 3.039

2.  Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study.

Authors:  K W Doo; E-Y Kang; H S Yong; O H Woo; K Y Lee; Y-W Oh
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

3.  Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) improves chest CT image quality and reduces radiation exposure.

Authors:  Tsuneo Yamashiro; Tetsuhiro Miyara; Osamu Honda; Hisashi Kamiya; Kiyoshi Murata; Yoshiharu Ohno; Noriyuki Tomiyama; Hiroshi Moriya; Mitsuhiro Koyama; Satoshi Noma; Ayano Kamiya; Yuko Tanaka; Sadayuki Murayama
Journal:  PLoS One       Date:  2014-08-25       Impact factor: 3.240

4.  Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.

Authors:  Ki Baek Lee; Hyun Woo Goo
Journal:  Korean J Radiol       Date:  2018-01-02       Impact factor: 3.500

Review 5.  Radiation dose reduction considerations and imaging patterns of ground glass opacities in coronavirus: risk of over exposure in computed tomography.

Authors:  Mohammad Ahmmad Rawashdeh; Charbel Saade
Journal:  Radiol Med       Date:  2020-09-08       Impact factor: 6.313