Literature DB >> 21983002

Three-dimensional fit of CAD/CAM-made zirconia copings.

Ovidiu Moldovan1, Ralph G Luthardt, Nicoleta Corcodel, Heike Rudolph.   

Abstract

OBJECTIVES: CAD/CAM-technologies aim for a standardized, accurate production of dental restorations out of high strength materials (zirconia). The three-dimensional internal fit of CAD/CAM-manufactured zirconia copings was evaluated in vitro to verify the realizability of this aim.
METHODS: The analysis was based on ceramic master dies of prepared teeth and corresponding virtual CAD surfaces. Five copings per die were manufactured with two different CAD/CAM-technologies: milling and grinding. The internal fit was determined by a three-dimensional replica technique by optical digitization and computer-assisted analysis.
RESULTS: Mean internal gaps were 134/84μm (SD 78/28) for molar and 93/69μm (SD 56/35) for premolar copings (milling/grinding) using a digitizable silicone for the replicas representing the cement space; they were statistically significant regarding tooth and CAD/CAM-system (p<0.001). SIGNIFICANCE: All zirconia copings showed an internal accuracy of fit where the gap widths ranged within the current clinical recommendations. However, there still is room for improvement and further standardization of CAD/CAM-technologies. Copyright Â
© 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21983002     DOI: 10.1016/j.dental.2011.09.006

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  27 in total

1.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

2.  The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems.

Authors:  Petya K Brawek; Stefan Wolfart; Lutz Endres; Armin Kirsten; Sven Reich
Journal:  Clin Oral Investig       Date:  2013-01-31       Impact factor: 3.573

3.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

4.  Fracture resistance of three-unit zirconia fixed partial denture with modified framework.

Authors:  Arthur Partiyan; Essam Osman; Mohammad M Rayyan; Moustafa Aboushelib; Ahmed Ibrahim; Ryo Jimbo
Journal:  Odontology       Date:  2016-04-15       Impact factor: 2.634

5.  Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Authors:  Brunna Mota Ferrairo; Fernanda Furtado Piras; Feranda Ferruzzi Lima; Heitor Marques Honório; Marco Antonio Hungaro Duarte; Ana Flávia Sanches Borges; José Henrique Rubo
Journal:  Clin Oral Investig       Date:  2020-08-11       Impact factor: 3.573

6.  Evaluation of different approaches for using a laser scanner in digitization of dental impressions.

Authors:  Wan-Sun Lee; Woong-Chul Kim; Hae-Young Kim; Wook-Tae Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

7.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

8.  Effect of span length on the fit of zirconia framework fabricated using CAD/CAM system.

Authors:  Jeong-Yol Lee; Sang-Jin Choi; Min-Soo Kim; Ha-Young Kim; Young-Soo Kim; Sang-Wan Shin
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

9.  Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques.

Authors:  Ki-Baek Kim; Jae-Hong Kim; Woong-Chul Kim; Hae-Young Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

10.  In vitro evaluation of the bond strength between various ceramics and cobalt-chromium alloy fabricated by selective laser sintering.

Authors:  Eun-Jeong Bae; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.