Literature DB >> 23357903

Membrane hydrophone measurement and numerical simulation of HIFU fields up to developed shock regimes.

Olga V Bessonova1, Volker Wilkens.   

Abstract

For the characterization of high-intensity focused ultrasound (HIFU) fields, hydrophone measurements should be performed in water in the whole range of the radiated power; however, cavitation occurs at high output, leading to the destruction of the hydrophone. To avoid this problem, a new hydrophone with additional protective layers covering the electrodes was developed and tested in the experiments. A single-element 1-MHz focusing ultrasound source was used for detailed measurements of the acoustic field in the axial and lateral planes. Measurements were performed with a new membrane hydrophone up to the focal peak compressional and rarefactional pressures of 55.6 and of 12.8 MPa, respectively, when the shock front had already formed in the waveform. Numerical modeling for the beams of periodic waves with an initially uniform amplitude distribution was performed, based on the Khokhlov-Zabolotskaya-Kuznetsov equation. Numerical solutions were compared with the experimental data and found to be in good agreement (within 10%). The influences of the limited bandwidth and the spatial averaging effect of the hydrophone on the accurate measurements of the acoustic field parameters were also investigated.

Entities:  

Year:  2013        PMID: 23357903     DOI: 10.1109/TUFFC.2013.2565

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  20 in total

1.  Infrared mapping of ultrasound fields generated by medical transducers: feasibility of determining absolute intensity levels.

Authors:  Vera A Khokhlova; Svetlana M Shmeleva; Leonid R Gavrilov; Eleanor Martin; Neelaksh Sadhoo; Adam Shaw
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Variation of High-Intensity Therapeutic Ultrasound (HITU) Pressure Field Characterization: Effects of Hydrophone Choice, Nonlinearity, Spatial Averaging and Complex Deconvolution.

Authors:  Yunbo Liu; Keith A Wear; Gerald R Harris
Journal:  Ultrasound Med Biol       Date:  2017-07-21       Impact factor: 2.998

4.  Correction for frequency-dependent hydrophone response to nonlinear pressure waves using complex deconvolution and rarefactional filtering: application with fiber optic hydrophones.

Authors:  Keith Wear; Yunbo Liu; Paul M Gammell; Subha Maruvada; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

5.  Directivity and Frequency-Dependent Effective Sensitive Element Size of Membrane Hydrophones: Theory Versus Experiment.

Authors:  Keith A Wear; Christian Baker; Piero Miloro
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-24       Impact factor: 2.725

6.  Shock formation and nonlinear saturation effects in the ultrasound field of a diagnostic curvilinear probe.

Authors:  Maria M Karzova; Petr V Yuldashev; Oleg A Sapozhnikov; Vera A Khokhlova; Bryan W Cunitz; Wayne Kreider; Michael R Bailey
Journal:  J Acoust Soc Am       Date:  2017-04       Impact factor: 1.840

7.  Dependence of inertial cavitation induced by high intensity focused ultrasound on transducer F-number and nonlinear waveform distortion.

Authors:  Tatiana Khokhlova; Pavel Rosnitskiy; Christopher Hunter; Adam Maxwell; Wayne Kreider; Gail Ter Haar; Marcia Costa; Oleg Sapozhnikov; Vera Khokhlova
Journal:  J Acoust Soc Am       Date:  2018-09       Impact factor: 1.840

8.  Correction for Hydrophone Spatial Averaging Artifacts for Circular Sources.

Authors:  Keith A Wear; Anant Shah; Christian Baker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-11-24       Impact factor: 2.725

9.  Rapid quantitative imaging of high intensity ultrasonic pressure fields.

Authors:  Huiwen Luo; Jiro Kusunose; Gianmarco Pinton; Charles F Caskey; William A Grissom
Journal:  J Acoust Soc Am       Date:  2020-08       Impact factor: 1.840

10.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.