Literature DB >> 12898388

A degeneracy study in the circulant and bordered-circulant approach to birdcage and planar coils.

Y-C N Cheng1, T P Eagan, T Chmielewski, J Flock, M-C Kang, T K Kidane, Sh M Shvartsman, R W Brown.   

Abstract

A method for finding closed-form solutions for the normal mode frequencies of systems with circulant (2 pi/n) symmetry was investigated. This method is particularly useful for questions of degeneracy that arise when one considers parallel imaging techniques like SENSE and SMASH in MRI. It is applicable to systems that include birdcage coils as well as planar coils with the appropriate rotational symmetry. A proof is given that complete degeneracy of all normal mode frequencies is impossible when all mutual inductive couplings are included. We tested the method against measurements made on a planar coil array and on an 8-element birdcage coil. The inclusion of the co-rotating end-ring mode changes the fundamental symmetry of the system from circulant to 'bordered circulant.' Closed-form solutions for the normal mode frequencies of a bordered circulant system are also given.

Mesh:

Year:  2003        PMID: 12898388     DOI: 10.1007/s10334-003-0009-5

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  6 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Coupling and decoupling theory and its application to the MRI phased array.

Authors:  Ray F Lee; Randy O Giaquinto; Christopher J Hardy
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

4.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

5.  BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

Authors:  Chih-Liang Chin; Christopher M Collins; Shizhe Li; Bernard J Dardzinski; Michael B Smith
Journal:  Concepts Magn Reson       Date:  2002-06-28

6.  Design of matching networks for low noise preamplifiers.

Authors:  A Reykowski; S M Wright; J R Porter
Journal:  Magn Reson Med       Date:  1995-06       Impact factor: 4.668

  6 in total
  2 in total

1.  A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy.

Authors:  Ryan Brown; Karthik Lakshmanan; Guillaume Madelin; Prodromos Parasoglou
Journal:  Neuroimage       Date:  2015-09-13       Impact factor: 6.556

2.  An eight-channel sodium/proton coil for brain MRI at 3 T.

Authors:  Karthik Lakshmanan; Ryan Brown; Guillaume Madelin; Yongxian Qian; Fernando Boada; Graham C Wiggins
Journal:  NMR Biomed       Date:  2017-12-27       Impact factor: 4.044

  2 in total