Literature DB >> 15538658

An efficient design for birdcage probes dedicated to small-animal imaging experiments.

M Lupu1, J L Dimicoli, A Volk, J Mispelter.   

Abstract

We are presenting, in this paper, a simple, easily reproducible and easily tuneable design for home-built birdcage probes inducing a linearly polarised B1 field. A simple tuning method is proposed which preserves the induced field homogeneity that characterises in general the birdcage design. This is achieved by adding two extra rings (link rings) that allow one to connect two opposed points on the birdcage end rings via tuning capacitors. All the development stages, from design to practical realisation, are presented, step by step, in order to facilitate experimentalist work. Some images obtained with the birdcage probe are presented, accompanied by the B1 maps in transverse as well as longitudinal planes. Finally, a few suggestions are made for obtaining a circularly polarised magnetic field configuration.

Mesh:

Year:  2004        PMID: 15538658     DOI: 10.1007/s10334-004-0059-3

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  6 in total

1.  Error-tolerant RF litz coils for NMR/MRI.

Authors:  F D Doty; G Entzminger; C D Hauck
Journal:  J Magn Reson       Date:  1999-09       Impact factor: 2.229

Review 2.  Sensitivity and power deposition in a high-field imaging experiment.

Authors:  D I Hoult; D Phil
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

3.  Practical aspects of birdcage coils.

Authors:  F D Doty; G Entzminger; C D Hauck; J P Staab
Journal:  J Magn Reson       Date:  1999-05       Impact factor: 2.229

4.  A birdcage coil tuned by RF shielding for application at 9.4 T.

Authors:  B J Dardzinski; S Li; C M Collins; G D Williams; M B Smith
Journal:  J Magn Reson       Date:  1998-03       Impact factor: 2.229

5.  BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

Authors:  Chih-Liang Chin; Christopher M Collins; Shizhe Li; Bernard J Dardzinski; Michael B Smith
Journal:  Concepts Magn Reson       Date:  2002-06-28

6.  Equivalent circuit for birdcage resonators.

Authors:  M D Harpen
Journal:  Magn Reson Med       Date:  1993-02       Impact factor: 4.668

  6 in total
  3 in total

1.  A 20-channel receive-only mouse array coil for a 3 T clinical MRI system.

Authors:  Boris Keil; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald; Florian M Meise; Laura M Schreiber; Klaus J Klose; Johannes T Heverhagen
Journal:  Magn Reson Med       Date:  2011-03-23       Impact factor: 4.668

2.  Simultaneous dynamic T1 and T2* measurement for AIF assessment combined with DCE MRI in a mouse tumor model.

Authors:  Melanie Heilmann; Christine Walczak; Julien Vautier; Jean-Luc Dimicoli; Carole D Thomas; Mihaela Lupu; Joël Mispelter; Andreas Volk
Journal:  MAGMA       Date:  2007-10-11       Impact factor: 2.310

3.  Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy.

Authors:  Wm Potter; L Wang; Kk McCully; Q Zhao
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2013-08-01       Impact factor: 1.176

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.