Literature DB >> 1881259

Generalized electrical analysis of low-pass and high-pass birdcage resonators.

R J Pascone1, B J Garcia, T M Fitzgerald, T Vullo, R Zipagan, P T Cahill.   

Abstract

The radio-frequency 'birdcage resonator' has found wide use in MRI/MRS for its field homogeneity and signal-noise characteristics. This paper presents a general analysis, derived from lumped element transmission line theory, of the electrical behavior of unloaded, N-column birdcage resonators applicable to several versions of the basic design including low-pass and high-pass coils. Analytic expressions and computer results are presented for both types of coil describing resonant frequencies, input and characteristic impedances, dispersion relations, pass-bands, resonant peak bandwidth and Q. Theoretical expressions for normalized resonant frequency difference ratios independent of element values and resonator geometry have been developed for generic low- and high-pass coils. Experimental measurements of resonant frequencies were made for six coils, and the average agreement with theoretical predictions was approximately 4%.

Entities:  

Mesh:

Year:  1991        PMID: 1881259     DOI: 10.1016/0730-725x(91)90428-o

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  A fast and accurate simulator for the design of birdcage coils in MRI.

Authors:  Giulio Giovannetti; Luigi Landini; Maria Filomena Santarelli; Vincenzo Positano
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

2.  BirdcageBuilder: Design of Specified-Geometry Birdcage Coils with Desired Current Pattern and Resonant Frequency.

Authors:  Chih-Liang Chin; Christopher M Collins; Shizhe Li; Bernard J Dardzinski; Michael B Smith
Journal:  Concepts Magn Reson       Date:  2002-06-28

3.  Advanced theory of driven birdcage resonator with losses for biomedical magnetic resonance imaging and spectroscopy.

Authors:  Alexander Novikov
Journal:  Magn Reson Imaging       Date:  2011-02       Impact factor: 2.546

4.  A volume birdcage coil with an adjustable sliding tuner ring for neuroimaging in high field vertical magnets: ex and in vivo applications at 21.1T.

Authors:  Chunqi Qian; Ihssan S Masad; Jens T Rosenberg; Malathy Elumalai; William W Brey; Samuel C Grant; Peter L Gor'kov
Journal:  J Magn Reson       Date:  2012-05-30       Impact factor: 2.229

5.  Electromagnetic characterisation of MR RF coils using the transmission-line modelling method.

Authors:  P J Cassidy; S Grieve; K Clarke; D J Edwards
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

  5 in total