Literature DB >> 23300039

Impact of organ-specific dose reduction on the image quality of head and neck CT angiography.

L Schimmöller1, R S Lanzman, P Heusch, S Dietrich, F Miese, J Aissa, T A Heusner, G Antoch, P Kröpil.   

Abstract

OBJECTIVES: Organ-specific dose reduction (OSDR) algorithms can reduce radiation on radiosensitive organs up to 59 %. This study evaluates the influence of a new OSDR algorithm on image quality of head and neck computed tomographic angiography (CTA) in clinical routine.
METHODS: Sixty-two consecutive patients (68 ± 13 years) were randomised into two groups and imaged using 128-row multidetector CT. Group A (n = 31) underwent conventional CTA and group B (n = 31) CTA with a novel OSDR algorithm. Subjective and objective image quality were statistically compared. Subjective image quality was rated on a five-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated with region-of-interest measurements.
RESULTS: The SNR of the common carotid artery and middle cerebral artery was 53.6 ± 22.7 and 43.3 ± 15.3 (group A) versus 54.1 ± 20.5 and 46.2 ± 14.6 (group B). The CNR was 40.0 ± 19.3 and 29.7 ± 12.0 (group A) compared with 40.7 ± 16.8 and 32.9 ± 10.9 (group B), respectively. Subjective image quality was excellent in both groups (mean score 4.4 ± 0.7 versus 4.4 ± 0.6). Differences between the two groups were not significant.
CONCLUSIONS: The novel OSDR algorithm does not compromise image quality of head and neck CTA. Its application can be recommended for CTA in clinical routine to protect the thyroid gland and ocular lenses from unnecessary high radiation. KEY POINTS: • Organ-specific dose reduction (OSDR) can significantly reduce radiation exposure during CT • OSDR does not compromise image quality of head and neck CTA • OSDR can significantly lower the risk of radiation damage to sensitive organs • OSDR can easily be applied in routine clinical practice.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23300039     DOI: 10.1007/s00330-012-2750-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  23 in total

1.  Organ-based computed tomographic (CT) radiation dose reduction to the lenses: impact on image quality for CT of the head.

Authors:  Anja Judith Reimann; Chris Davison; Thor Bjarnason; Yogesh Thakur; Thakur Yogesh; Karl Kryzmyk; John Mayo; Savvas Nicolaou
Journal:  J Comput Assist Tomogr       Date:  2012 May-Jun       Impact factor: 1.826

2.  [Awareness of radiation exposure of thoracic CT scans and conventional radiographs: what do non-radiologists know?].

Authors:  C M Heyer; S Peters; S Lemburg; V Nicolas
Journal:  Rofo       Date:  2007-01-29

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

Review 4.  Principles of CT: radiation dose and image quality.

Authors:  Lee W Goldman
Journal:  J Nucl Med Technol       Date:  2007-11-15

5.  Medical radiation exposure in the U.S. in 2006: preliminary results.

Authors:  Fred A Mettler; Bruce R Thomadsen; Mythreyi Bhargavan; Debbie B Gilley; Joel E Gray; Jill A Lipoti; John McCrohan; Terry T Yoshizumi; Mahadevappa Mahesh
Journal:  Health Phys       Date:  2008-11       Impact factor: 1.316

6.  Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma.

Authors:  Patric Kröpil; Roland Fenk; Lars B Fritz; Dirk Blondin; Guido Kobbe; Ulrich Mödder; Mathias Cohnen
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

7.  Automated computed tomography dose-saving algorithm to protect radiosensitive tissues: estimation of radiation exposure and image quality considerations.

Authors:  Dominik Ketelsen; Markus Buchgeister; Michael Fenchel; Bernhard Schmidt; Thomas G Flohr; Roland Syha; Christoph Thomas; Ilias Tsiflikas; Claus D Claussen; Martin Heuschmid
Journal:  Invest Radiol       Date:  2012-02       Impact factor: 6.016

8.  Iterative reconstruction improves evaluation of native aortic and mitral valves by retrospectively ECG-gated thoracoabdominal CTA.

Authors:  Martin J Willemink; Jesse Habets; Pim A de Jong; Arnold M R Schilham; Willem P Th M Mali; Tim Leiner; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2012-10-13       Impact factor: 5.315

9.  Bismuth shielding, organ-based tube current modulation, and global reduction of tube current for dose reduction to the eye at head CT.

Authors:  Jia Wang; Xinhui Duan; Jodie A Christner; Shuai Leng; Katharine L Grant; Cynthia H McCollough
Journal:  Radiology       Date:  2012-01       Impact factor: 11.105

10.  Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists.

Authors:  Gabriel Chodick; Nural Bekiroglu; Michael Hauptmann; Bruce H Alexander; D Michal Freedman; Michele Morin Doody; Li C Cheung; Steven L Simon; Robert M Weinstock; André Bouville; Alice J Sigurdson
Journal:  Am J Epidemiol       Date:  2008-07-29       Impact factor: 4.897

View more
  2 in total

1.  Evaluation of the impact of organ-specific dose reduction on image quality in pediatric chest computed tomography.

Authors:  Johannes Boos; Patric Kröpil; Dirk Klee; Philipp Heusch; Lars Schimmöller; Jörg Schaper; Gerald Antoch; Rotem S Lanzman
Journal:  Pediatr Radiol       Date:  2014-03-29

2.  Impact of increasing levels of adaptive statistical iterative reconstruction on image quality in oil-based postmortem CT angiography in coronary arteries.

Authors:  Andrea Steuwe; Judith Boeven; Lena Cordes; Stefano Draisci; Johannes Boos; Silke Grabherr; Christine Bruguier; Hannan Dalyanoglu; Gerald Antoch; Joel Aissa
Journal:  Int J Legal Med       Date:  2021-02-24       Impact factor: 2.686

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.