Literature DB >> 11181005

Application of an [(18)F]fluorodeoxyglucose-sensitive probe for the intraoperative detection of malignancy.

R Essner1, E C Hsueh, P I Haigh, E C Glass, Y Huynh, F Daghighian.   

Abstract

BACKGROUND: Whole-body positron emission tomography (PET) has been shown to be a highly sensitive method for detecting malignancy not imaged by conventional modalities. We have adapted a hand-held gamma-ray-sensitive probe to detect the radiation emission from the [(18)F]fluorodeoxyglucose (FDG) used in PET imaging. This pilot study was devised to examine the feasibility of using a hand-held probe to intraoperatively differentiate normal from tumor-bearing tissue.
MATERIALS AND METHODS: A commercially available gamma probe was adapted to detect the radioactivity released from FDG and examined to determine the in vitro sensitivity for localization of a FDG point source. Eight consecutive patients underwent resection of metastatic colon cancer or melanoma; each received a preoperative injection of 7--10 mCi of FDG. The gamma probe was used to determine radioactive counts per second from tumor and normal tissue, and ratios of tumor to adjacent normal background were calculated.
RESULTS: In vitro studies with a FDG point source demonstrated the probe could identify the source with a 50% reduction in maximum counts 1.7 +/- 0.1 cm from the source (full-width half-maximum measurement). Based on the results of their preoperative PET scans 17 tumors were identified from the 8 patients. Of the 17 tumors assessed the in vivo tumor-to-background ratios varied from 1.16:1 to 4.67:1 for the melanoma patients (13 tumors) and from 1.19:1 to 7.92:1 for colon cancer patients (4 tumors). Thirteen tumors were resected; four (2 patients) were unresectable.
CONCLUSIONS: This study demonstrates the use of a hand-held gamma-ray-sensitive probe to intraoperatively differentiate the radioactivity released from FDG from tumor-bearing and adjacent normal tissue. While further studies are necessary for us to optimize the use of this probe, the intraoperative detection of FDG-avid malignancies may ultimately improve our ability to completely resect patients with metastatic disease. Copyright 2001 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11181005     DOI: 10.1006/jsre.2000.6069

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  19 in total

1.  PET probes and oncological surgery: a productive new marriage for nuclear medicine?

Authors:  Orazio Schillaci
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10       Impact factor: 9.236

2.  Comprehensive evaluation of occupational radiation exposure to intraoperative and perioperative personnel from 18F-FDG radioguided surgical procedures.

Authors:  Stephen P Povoski; Ismet Sarikaya; William C White; Steven G Marsh; Nathan C Hall; George H Hinkle; Edward W Martin; Michael V Knopp
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07-10       Impact factor: 9.236

3.  A GSO tweezers-type coincidence detector for tumor detection.

Authors:  Seiichi Yamamoto; Tatsuya Higashi; Michio Senda
Journal:  Radiol Phys Technol       Date:  2013-01-03

4.  The use of intraoperative PET probe to resect metastatic melanoma.

Authors:  Grant O Lee; Nicholas G Costouros; Terry Groome; Mohammed Kashani-Sabet; Stanley P L Leong
Journal:  BMJ Case Rep       Date:  2010-07-15

Review 5.  A comprehensive overview of radioguided surgery using gamma detection probe technology.

Authors:  Stephen P Povoski; Ryan L Neff; Cathy M Mojzisik; David M O'Malley; George H Hinkle; Nathan C Hall; Douglas A Murrey; Michael V Knopp; Edward W Martin
Journal:  World J Surg Oncol       Date:  2009-01-27       Impact factor: 2.754

6.  Evaluation and clinically relevant applications of a fluorescent imaging analog to fluorodeoxyglucose positron emission tomography.

Authors:  Rahul A Sheth; Lee Josephson; Umar Mahmood
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

7.  A novel method to localize antibody-targeted cancer deposits intraoperatively using handheld PET beta and gamma probes.

Authors:  Vivian E Strong; John Humm; Paul Russo; Achim Jungbluth; W Douglas Wong; Farhad Daghighian; Lloyd Old; Yuman Fong; Steven M Larson
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

8.  Prospective comparison of two gamma probes for intraoperative detection of 18F-FDG: in vitro assessment and clinical evaluation in differentiated thyroid cancer patients with iodine-negative recurrence.

Authors:  Chantal Curtet; Thomas Carlier; Eric Mirallié; Caroline Bodet-Milin; Caroline Rousseau; Jacques Barbet; Francoise Kraeber-Bodéré
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-05-24       Impact factor: 9.236

9.  Portable PET probes are a novel tool for intraoperative localization of tumor deposits.

Authors:  Vivian E Strong; Charles J Galanis; Christopher C Riedl; Valerie A Longo; Farhad Daghighian; John L Humm; Steven M Larson; Yuman Fong
Journal:  Ann Surg Innov Res       Date:  2009-02-21

10.  Radiation exposure to surgical staff during F-18-FDG-guided cancer surgery.

Authors:  P A Andersen; A H Chakera; T L Klausen; T Binderup; H S Grossjohann; E Friis; C Palnaes Hansen; G Schmidt; A Kjaer; B Hesse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-23       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.