Literature DB >> 14761021

Positronium: review of symmetry, conserved quantities and decay for the radiological physicist.

Michael D Harpen1.   

Abstract

The PET-CT scanner, which overlays a high spatial resolution CT image on a relatively low resolution physiologic PET image, has greatly increased the efficacy of the PET imaging modality. With the resulting increase in the presence of PET imaging in the radiologic and medical physics communities, medical physicists can expect professional responsibilities in acceptance testing, quality assurance, radiation safety and resident teaching of this new modality. With this in mind we present a review of a subtle aspect of PET: the formation, symmetry properties and decay of positronium; the hydrogen like positron-electron complex which forms prior to annihilation.

Entities:  

Mesh:

Year:  2004        PMID: 14761021     DOI: 10.1118/1.1630494

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  A GSO tweezers-type coincidence detector for tumor detection.

Authors:  Seiichi Yamamoto; Tatsuya Higashi; Michio Senda
Journal:  Radiol Phys Technol       Date:  2013-01-03

2.  Genuine Multipartite Entanglement in the 3-Photon Decay of Positronium.

Authors:  Beatrix C Hiesmayr; Pawel Moskal
Journal:  Sci Rep       Date:  2017-11-10       Impact factor: 4.379

3.  Performance assessment of the 2 γpositronium imaging with the total-body PET scanners.

Authors:  P Moskal; D Kisielewska; R Y Shopa; Z Bura; J Chhokar; C Curceanu; E Czerwiński; M Dadgar; K Dulski; J Gajewski; A Gajos; M Gorgol; R Del Grande; B C Hiesmayr; B Jasińska; K Kacprzak; A Kamińska; Ł Kapłon; H Karimi; G Korcyl; P Kowalski; N Krawczyk; W Krzemień; T Kozik; E Kubicz; P Małczak; M Mohammed; Sz Niedźwiecki; M Pałka; M Pawlik-Niedźwiecka; M Pędziwiatr; L Raczyński; J Raj; A Ruciński; S Sharma; S Shivani; M Silarski; M Skurzok; E Ł Stępień; S Vandenberghe; W Wiślicki; B Zgardzińska
Journal:  EJNMMI Phys       Date:  2020-06-30

4.  Witnessing Entanglement In Compton Scattering Processes Via Mutually Unbiased Bases.

Authors:  Beatrix C Hiesmayr; Pawel Moskal
Journal:  Sci Rep       Date:  2019-06-03       Impact factor: 4.379

5.  A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators.

Authors:  D Kamińska; A Gajos; E Czerwiński; D Alfs; T Bednarski; P Białas; C Curceanu; K Dulski; B Głowacz; N Gupta-Sharma; M Gorgol; B C Hiesmayr; B Jasińska; G Korcyl; P Kowalski; W Krzemień; N Krawczyk; E Kubicz; M Mohammed; Sz Niedźwiecki; M Pawlik-Niedźwiecka; L Raczyński; Z Rudy; M Silarski; A Wieczorek; W Wiślicki; B Zgardzińska; M Zieliński; P Moskal
Journal:  Eur Phys J C Part Fields       Date:  2016-08-09       Impact factor: 4.590

6.  Positron annihilation localization by nanoscale magnetization.

Authors:  Yaser H Gholami; Hushan Yuan; Moses Q Wilks; Lee Josephson; Georges El Fakhri; Marc D Normandin; Zdenka Kuncic
Journal:  Sci Rep       Date:  2020-11-20       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.