Literature DB >> 23264711

Development of a Head Scanner for Proton CT.

H F-W Sadrozinski1, R P Johnson, S Macafee, A Plumb, D Steinberg, A Zatserklyaniy, V Bashkirov F Hurley, R Schulte.   

Abstract

We describe a new head scanner developed for Proton Computed Tomography (pCT) in support of proton therapy treatment planning, aiming at reconstructing an accurate map of the stopping power (S.P.) in a phantom and, in the future, in patients. The system consists of two silicon telescopes which track the proton before and after the phantom/patient, and an energy detector which measures the residual energy or range of the proton to reconstruct the Water Equivalent Path Length (WEPL) in the phantom. Based on the experience of the existing prototype and extensive Geant4 simulations and CT reconstructions, the new pCT scanner will support clinically useful proton fluxes.

Entities:  

Year:  2012        PMID: 23264711      PMCID: PMC3524593          DOI: 10.1016/j.nima.2012.04.029

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  2 in total

1.  The most likely path of an energetic charged particle through a uniform medium.

Authors:  D C Williams
Journal:  Phys Med Biol       Date:  2004-07-07       Impact factor: 3.609

2.  Water-equivalent path length calibration of a prototype proton CT scanner.

Authors:  R F Hurley; R W Schulte; V A Bashkirov; A J Wroe; A Ghebremedhin; H F-W Sadrozinski; V Rykalin; G Coutrakon; P Koss; B Patyal
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

  2 in total
  19 in total

1.  Novel scintillation detector design and performance for proton radiography and computed tomography.

Authors:  V A Bashkirov; R W Schulte; R F Hurley; R P Johnson; H F-W Sadrozinski; A Zatserklyaniy; T Plautz; V Giacometti
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Tracker Readout ASIC for Proton Computed Tomography Data Acquisition.

Authors:  Robert P Johnson; Joel Dewitt; Cole Holcomb; Scott Macafee; Hartmut F-W Sadrozinski; David Steinberg
Journal:  IEEE Trans Nucl Sci       Date:  2013-10       Impact factor: 1.679

3.  The effect of beam purity and scanner complexity on proton CT accuracy.

Authors:  P Piersimoni; J Ramos-Méndez; T Geoghegan; V A Bashkirov; R W Schulte; B A Faddegon
Journal:  Med Phys       Date:  2017-01-09       Impact factor: 4.071

4.  Proton tracking for medical imaging and dosimetry.

Authors:  J T Taylor; P P Allport; G L Casse; N A Smith; I Tsurin; N M Allinson; M Esposito; A Kacperek; J Nieto-Camero; T Price; C Waltham
Journal:  J Instrum       Date:  2015-02-10       Impact factor: 1.415

5.  Operation of the Preclinical Head Scanner for Proton CT.

Authors:  H F-W Sadrozinski; T Geoghegan; E Harvey; R P Johnson; T E Plautz; A Zatserklyaniy; V Bashkirov; R F Hurley; P Piersimoni; R W Schulte; P Karbasi; K E Schubert; B Schultze; V Giacometti
Journal:  Nucl Instrum Methods Phys Res A       Date:  2016-02-07       Impact factor: 1.455

6.  Proton-counting radiography for proton therapy: a proof of principle using CMOS APS technology.

Authors:  G Poludniowski; N M Allinson; T Anaxagoras; M Esposito; S Green; S Manolopoulos; J Nieto-Camero; D J Parker; T Price; P M Evans
Journal:  Phys Med Biol       Date:  2014-05-01       Impact factor: 3.609

7.  Development of a high resolution voxelised head phantom for medical physics applications.

Authors:  V Giacometti; S Guatelli; M Bazalova-Carter; A B Rosenfeld; R W Schulte
Journal:  Phys Med       Date:  2017-01-17       Impact factor: 2.685

8.  200 MeV proton radiography studies with a hand phantom using a prototype proton CT scanner.

Authors:  Tia Plautz; V Bashkirov; V Feng; F Hurley; R P Johnson; C Leary; S Macafee; A Plumb; V Rykalin; H F-W Sadrozinski; K Schubert; R Schulte; B Schultze; D Steinberg; M Witt; A Zatserklyaniy
Journal:  IEEE Trans Med Imaging       Date:  2014-04       Impact factor: 10.048

9.  Development of proton computed tomography detectors for applications in hadron therapy.

Authors:  Vladimir A Bashkirov; Robert P Johnson; Hartmut F-W Sadrozinski; Reinhard W Schulte
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-08-08       Impact factor: 1.455

10.  A Fast Experimental Scanner for Proton CT: Technical Performance and First Experience with Phantom Scans.

Authors:  Robert P Johnson; Vladimir Bashkirov; Langley DeWitt; Valentina Giacometti; Robert F Hurley; Pierluigi Piersimoni; Tia E Plautz; Hartmut F-W Sadrozinski; Keith Schubert; Reinhard Schulte; Blake Schultze; Andriy Zatserklyaniy
Journal:  IEEE Trans Nucl Sci       Date:  2015-12-10       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.