Literature DB >> 24653525

Tracker Readout ASIC for Proton Computed Tomography Data Acquisition.

Robert P Johnson1, Joel Dewitt1, Cole Holcomb1, Scott Macafee1, Hartmut F-W Sadrozinski1, David Steinberg1.   

Abstract

A unique CMOS chip has been designed to serve as the front-end of the tracking detector data acquisition system of a pre-clinical prototype scanner for proton computed tomography (pCT). The scanner is to be capable of measuring one to two million proton tracks per second, so the chip must be able to digitize the data and send it out rapidly while keeping the front-end amplifiers active at all times. One chip handles 64 consecutive channels, including logic for control, calibration, triggering, buffering, and zero suppression. It outputs a formatted cluster list for each trigger, and a set of field programmable gate arrays merges those lists from many chips to build the events to be sent to the data acquisition computer. The chip design has been fabricated, and subsequent tests have demonstrated that it meets all of its performance requirements, including excellent low-noise performance.

Entities:  

Keywords:  Application specific integrated circuits; computed tomography; low-noise amplifiers; mixed analog digital integrated circuits; particle tracking; silicon radiation detectors

Year:  2013        PMID: 24653525      PMCID: PMC3957097          DOI: 10.1109/TNS.2013.2274663

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  5 in total

1.  Treatment planning and verification of proton therapy using spot scanning: initial experiences.

Authors:  Antony J Lomax; Terence Böhringer; Alessandra Bolsi; Doelf Coray; Frank Emert; Gudrun Goitein; Martin Jermann; Shixiong Lin; Eros Pedroni; Hanspeter Rutz; Otto Stadelmann; Beate Timmermann; Jorn Verwey; Damien C Weber
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

2.  Radiological use of fast protons.

Authors:  R R WILSON
Journal:  Radiology       Date:  1946-11       Impact factor: 11.105

3.  A case study in proton pencil-beam scanning delivery.

Authors:  Hanne M Kooy; Benjamin M Clasie; Hsiao-Ming Lu; Thomas M Madden; Hassan Bentefour; Nicolas Depauw; Judy A Adams; Alexei V Trofimov; Denis Demaret; Thomas F Delaney; Jacob B Flanz
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-02-01       Impact factor: 7.038

4.  A performance study of the Loma Linda proton medical accelerator.

Authors:  G Coutrakon; J Hubbard; J Johanning; G Maudsley; T Slaton; P Morton
Journal:  Med Phys       Date:  1994-11       Impact factor: 4.071

5.  Development of a Head Scanner for Proton CT.

Authors:  H F-W Sadrozinski; R P Johnson; S Macafee; A Plumb; D Steinberg; A Zatserklyaniy; V Bashkirov F Hurley; R Schulte
Journal:  Nucl Instrum Methods Phys Res A       Date:  2012-04-13       Impact factor: 1.455

  5 in total
  6 in total

1.  An evaluation of spatial resolution of a prototype proton CT scanner.

Authors:  Tia E Plautz; V Bashkirov; V Giacometti; R F Hurley; R P Johnson; P Piersimoni; H F-W Sadrozinski; R W Schulte; A Zatserklyaniy
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

2.  Operation of the Preclinical Head Scanner for Proton CT.

Authors:  H F-W Sadrozinski; T Geoghegan; E Harvey; R P Johnson; T E Plautz; A Zatserklyaniy; V Bashkirov; R F Hurley; P Piersimoni; R W Schulte; P Karbasi; K E Schubert; B Schultze; V Giacometti
Journal:  Nucl Instrum Methods Phys Res A       Date:  2016-02-07       Impact factor: 1.455

3.  Development of a high resolution voxelised head phantom for medical physics applications.

Authors:  V Giacometti; S Guatelli; M Bazalova-Carter; A B Rosenfeld; R W Schulte
Journal:  Phys Med       Date:  2017-01-17       Impact factor: 2.685

4.  Development of proton computed tomography detectors for applications in hadron therapy.

Authors:  Vladimir A Bashkirov; Robert P Johnson; Hartmut F-W Sadrozinski; Reinhard W Schulte
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-08-08       Impact factor: 1.455

5.  A Fast Experimental Scanner for Proton CT: Technical Performance and First Experience with Phantom Scans.

Authors:  Robert P Johnson; Vladimir Bashkirov; Langley DeWitt; Valentina Giacometti; Robert F Hurley; Pierluigi Piersimoni; Tia E Plautz; Hartmut F-W Sadrozinski; Keith Schubert; Reinhard Schulte; Blake Schultze; Andriy Zatserklyaniy
Journal:  IEEE Trans Nucl Sci       Date:  2015-12-10       Impact factor: 1.679

6.  Software platform for simulation of a prototype proton CT scanner.

Authors:  Valentina Giacometti; Vladimir A Bashkirov; Pierluigi Piersimoni; Susanna Guatelli; Tia E Plautz; Hartmut F-W Sadrozinski; Robert P Johnson; Andriy Zatserklyaniy; Thomas Tessonnier; Katia Parodi; Anatoly B Rosenfeld; Reinhard W Schulte
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.506

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.