Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Chi Ma1, Tomy Varghese.   

Abstract

Echocardiographic strain imaging is a promising new method for quantifying and displaying the health of cardiac muscle. Accurate regional myocardial function analysis requires high spatial and temporal resolution in addition to fidelity to the underlying deformation. However, all current clinical approaches use speckle-tracking algorithms applied to B-mode images derived from envelope signals. Such approaches are inherently of lower spatial resolution, since they require larger data blocks for deformation tracking due to the absence of phase information. In this paper, we compare the strain estimation performance using B-mode, envelope and radiofrequency signals, utilizing data acquired from a uniformly elastic tissue mimicking phantom, cardiac simulation, and clinical in vivo data. Signal-to-noise ratio improvements using radiofrequency signals for linear and phased array geometries were 5.80 dB and 9.48 dB over that obtained with envelope signals (at peak strain) in phantom studies, respectively. Cardiac simulation studies demonstrate that when averaged over the two cardiac cycles, the mean standard deviation of estimated strain using envelope signals from two of the six segments for a short-axes view (anterior and anterolateral) were 48% and 44% higher than that obtained using radiofrequency signals. These segments were chosen since one was along while the other was situated lateral to the beam propagation direction. In a similar manner, in vivo analysis on a volunteer also indicate that the standard deviation of the estimated strain using B-mode and envelope signals were 16% and 42% higher than that obtained using radiofrequency signals in the anteroseptal segment, and 45% and 27% in the anterior segment. These results demonstrate the significant reduction in the variability of strain estimated along with improvements in the spatial resolution and signal-to-noise ratios obtained using radiofrequency signals.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23259981      PMCID: PMC3650907          DOI: 10.1016/j.ultras.2012.11.005

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  44 in total

Review 1.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association.

Authors:  Manuel D Cerqueira; Neil J Weissman; Vasken Dilsizian; Alice K Jacobs; Sanjiv Kaul; Waren K Laskey; Dudley J Pennell; John A Rumberger; Thomas Ryan; Mario S Verani
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

2.  Multiresolution imaging in elastography.

Authors:  T Varghese; M Bilgen; J Ophir
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

3.  Accuracy of sonographic elastography in the differential diagnosis of enlarged cervical lymph nodes: comparison with conventional B-mode sonography.

Authors:  Farzana Alam; Kumiko Naito; Jun Horiguchi; Hiroshi Fukuda; Toshihiro Tachikake; Katsuhide Ito
Journal:  AJR Am J Roentgenol       Date:  2008-08       Impact factor: 3.959

4.  A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues.

Authors:  E Konofagou; J Ophir
Journal:  Ultrasound Med Biol       Date:  1998-10       Impact factor: 2.998

5.  Noise reduction in elastograms using temporal stretching with multicompression averaging.

Authors:  T Varghese; J Ophir; I Céspedes
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

6.  Elastography: elasticity imaging using ultrasound with application to muscle and breast in vivo.

Authors:  I Céspedes; J Ophir; H Ponnekanti; N Maklad
Journal:  Ultrason Imaging       Date:  1993-04       Impact factor: 1.578

7.  Axial-shear strain imaging for differentiating benign and malignant breast masses.

Authors:  Haiyan Xu; Min Rao; Tomy Varghese; Amy Sommer; Sara Baker; Timothy J Hall; Gale A Sisney; Elizabeth S Burnside
Journal:  Ultrasound Med Biol       Date:  2010-11       Impact factor: 2.998

8.  Myocardial elastography at both high temporal and spatial resolution for the detection of infarcts.

Authors:  Jianwen Luo; Kana Fujikura; Shunichi Homma; Elisa E Konofagou
Journal:  Ultrasound Med Biol       Date:  2007-06-13       Impact factor: 2.998

9.  Regional myocardial perfusion and mechanics: a model-based method of analysis.

Authors:  R Mazhari; J H Omens; L K Waldman; A D McCulloch
Journal:  Ann Biomed Eng       Date:  1998 Sep-Oct       Impact factor: 3.934

10.  Ultrasonic imaging of myocardial strain using cardiac elastography.

Authors:  Tomy Varghese; J A Zagzebski; P Rahko; C S Breburda
Journal:  Ultrason Imaging       Date:  2003-01       Impact factor: 1.578

View more
  16 in total

1.  Analysis of 2-d ultrasound cardiac strain imaging using joint probability density functions.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2014-03-06       Impact factor: 2.998

Review 2.  Imaging the Propagation of the Electromechanical Wave in Heart Failure Patients with Cardiac Resynchronization Therapy.

Authors:  Ethan Bunting; Litsa Lambrakos; Paul Kemper; William Whang; Hasan Garan; Elisa Konofagou
Journal:  Pacing Clin Electrophysiol       Date:  2016-12-02       Impact factor: 1.976

3.  Cardiac Lesion Mapping In Vivo Using Intracardiac Myocardial Elastography.

Authors:  Ethan Bunting; Clement Papadacci; Elaine Wan; Vincent Sayseng; Julien Grondin; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-01       Impact factor: 2.725

4.  Stochastic precision analysis of 2D cardiac strain estimation in vivo.

Authors:  E A Bunting; J Provost; E E Konofagou
Journal:  Phys Med Biol       Date:  2014-10-21       Impact factor: 3.609

5.  Hierarchical Motion Estimation With Bayesian Regularization in Cardiac Elastography: Simulation and In Vivo Validation.

Authors:  Rashid Al Mukaddim; Nirvedh H Meshram; Carol C Mitchell; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-07-12       Impact factor: 2.725

6.  Catheter Ablation Lesion Visualization With Intracardiac Strain Imaging in Canines and Humans.

Authors:  Vincent Sayseng; Julien Grondin; Vasant A Salgaonkar; Christopher S Grubb; Maryam Basij; Mohammad Mehrmohammadi; Vivek Iyer; Daniel Wang; Hasan Garan; Elaine Y Wan; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-04-15       Impact factor: 2.725

7.  Monitoring Canine Myocardial Infarction Formation and Recovery via Transthoracic Cardiac Strain Imaging.

Authors:  Vincent Sayseng; Rebecca A Ober; Christopher S Grubb; Rachel A Weber; Elisa Konofagou
Journal:  Ultrasound Med Biol       Date:  2020-07-27       Impact factor: 2.998

8.  Intracardiac myocardial elastography in canines and humans in vivo.

Authors:  Julien Grondin; Elaine Wan; Alok Gambhir; Hasan Garan; Elisa Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

9.  Segmental Analysis of Cardiac Short-Axis Views Using Lagrangian Radial and Circumferential Strain.

Authors:  Chi Ma; Xiao Wang; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2015-11-16       Impact factor: 1.578

10.  Radial basis functions for combining shape and speckle tracking in 4D echocardiography.

Authors:  Colin B Compas; Emily Y Wong; Xiaojie Huang; Smita Sampath; Ben A Lin; Prasanta Pal; Xenophon Papademetris; Karl Thiele; Donald P Dione; Mitchel Stacy; Lawrence H Staib; Albert J Sinusas; Matthew O'Donnell; James S Duncan
Journal:  IEEE Trans Med Imaging       Date:  2014-06       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.