Literature DB >> 9004428

Noise reduction in elastograms using temporal stretching with multicompression averaging.

T Varghese1, J Ophir, I Céspedes.   

Abstract

Elastography uses estimates of the time delay (obtained by cross-correlation) to compute strain estimates in tissue due to quasistatic compression. Because the time delay estimates do not generally occur at the sampling intervals, the location of the cross-correlation peak does not give an accurate estimate of the time delay. Sampling errors in the time-delay estimate are reduced using signal interpolation techniques to obtain subsample time-delay estimates. Distortions of the echo signals due to tissue compression introduce correlation artifacts in the elastogram. These artifacts are reduced by a combination of small compressions and temporal stretching of the postcompression signal. Random noise effects in the resulting elastograms are reduced by averaging several elastograms, obtained from successive small compressions (assuming that the errors are uncorrelated). Multicompression averaging with temporal stretching is shown to increase the signal-to-noise ratio in the elastogram by an order of magnitude, without sacrificing sensitivity, resolution or dynamic range. The strain filter concept is extended in this article to theoretically characterize the performance of multicompression averaging with temporal stretching.

Mesh:

Year:  1996        PMID: 9004428     DOI: 10.1016/s0301-5629(96)00128-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  19 in total

1.  Maximum-likelihood approach to strain imaging using ultrasound

Authors: 
Journal:  J Acoust Soc Am       Date:  2000-03       Impact factor: 1.840

2.  Ultrasound elastography based on multiscale estimations of regularized displacement fields.

Authors:  Claire Pellot-Barakat; Frédérique Frouin; Michael F Insana; Alain Herment
Journal:  IEEE Trans Med Imaging       Date:  2004-02       Impact factor: 10.048

3.  Improvements in elastographic contrast-to-noise ratio using spatial-angular compounding.

Authors:  Udomchai Techavipoo; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2005-04       Impact factor: 2.998

4.  Spatial angular compounding for elastography without the incompressibility assumption.

Authors:  Min Rao; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2005-10       Impact factor: 1.578

5.  Spatial-angular compounding for elastography using beam steering on linear array transducers.

Authors:  Min Rao; Quan Chen; Hairong Shi; Tomy Varghese
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

6.  Correlation analysis of the beam angle dependence for elastography.

Authors:  Min Rao; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2006-06       Impact factor: 1.840

7.  Two-dimensional simulations of displacement accumulation incorporating shear strain.

Authors:  Matthew Bayer; Timothy J Hall; Lucio P Neves; A A O Carneiro
Journal:  Ultrason Imaging       Date:  2014-01       Impact factor: 1.578

8.  Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasonics       Date:  2012-11-29       Impact factor: 2.890

9.  Variance and covariance of accumulated displacement estimates.

Authors:  Matthew Bayer; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

10.  Large-Strain 3-D in Vivo Breast Ultrasound Strain Elastography Using a Multi-compression Strategy and a Whole-Breast Scanning System.

Authors:  Yuqi Wang; Matthew Bayer; Jingfeng Jiang; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2019-09-21       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.