Multiresolution imaging in elastography.

T Varghese1, M Bilgen, J Ophir.   

Abstract

The range of strains that can be imaged by any practical elastographic imaging system is inherently limited, and a performance measure is valuable to evaluate these systems from the signal and noise properties of their output images. Such a measure was previously formulated for systems employing cross-correlation based time-delay estimators through the strain filter. While the strain filter predicts the signal-to-noise ratio (SNR(e)) for each tissue strain in the elastogram and provides valuable insights into the nature of image noise, it understated the effects of image resolution (axial resolution, as determined by the cross-correlation window length) on the noise. In this work, the strain filter is modified to study the strain noise at multiple resolutions. The effects of finite window length on signal decorrelation and on the variance of the strain estimator are investigated. Long-duration windows are preferred for improved sensitivity, dynamic range, and SNR(e). However, in this limit the elastogram is degraded due to poor resolution. The results indicate that for nonzero strain, a window length exists at which the variance of strain estimator attains its minima, and consequently the elastographic sensitivity, dynamic range and SNR(e) are strongly affected by the selected window length. Simulation results corroborate the theoretical results, illustrating the presence of a window length where the strain estimation variance is minimized for a given strain value. Multiresolution elastography, where the strain estimate with the highest SNR(e) obtained by processing the pre- and post-compression waveforms at different window lengths is used to generate a composite elastogram and is proposed to improve elastograms. All the objective elastogram parameters (namely: SNR(e), dynamic range, sensitivity and the average elastographic resolution-defined as the cross-correlation window length) are improved with multiresolution elastography when compared to the traditional method of utilizing a single window length to generate the elastogram. Experimental results using a phantom with a hard inclusion illustrates the improvement in elastogram obtained using multiresolution analysis.

Year:  1998        PMID: 18244159     DOI: 10.1109/58.646912

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  Ultrasound elastography based on multiscale estimations of regularized displacement fields.

Authors:  Claire Pellot-Barakat; Frédérique Frouin; Michael F Insana; Alain Herment
Journal:  IEEE Trans Med Imaging       Date:  2004-02       Impact factor: 10.048

2.  Lagrangian displacement tracking using a polar grid between endocardial and epicardial contours for cardiac strain imaging.

Authors:  Chi Ma; Tomy Varghese
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Improvement of elastographic displacement estimation using a two-step cross-correlation method.

Authors:  Hao Chen; Hairong Shi; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2007-01       Impact factor: 2.998

4.  Correlation analysis of the beam angle dependence for elastography.

Authors:  Min Rao; Tomy Varghese
Journal:  J Acoust Soc Am       Date:  2006-06       Impact factor: 1.840

5.  Multilevel hybrid 2D strain imaging algorithm for ultrasound sector/phased arrays.

Authors:  Hao Chen; Tomy Varghese
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

Review 6.  Medical ultrasound: imaging of soft tissue strain and elasticity.

Authors:  Peter N T Wells; Hai-Dong Liang
Journal:  J R Soc Interface       Date:  2011-06-16       Impact factor: 4.118

7.  Ultrasonic measurement of scleral cross-sectional strains during elevations of intraocular pressure: method validation and initial results in posterior porcine sclera.

Authors:  Junhua Tang; Jun Liu
Journal:  J Biomech Eng       Date:  2012-09       Impact factor: 2.097

8.  Ultrasound 2D Strain Estimator Based on Image Registration for Ultrasound Elastography.

Authors:  Xiaofeng Yang; Mylin Torres; Stephanie Kirkpatrick; Walter J Curran; Tian Liu
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-03-20

9.  Comparison of cardiac displacement and strain imaging using ultrasound radiofrequency and envelope signals.

Authors:  Chi Ma; Tomy Varghese
Journal:  Ultrasonics       Date:  2012-11-29       Impact factor: 2.890

10.  Methods for robust in vivo strain estimation in the carotid artery.

Authors:  M McCormick; T Varghese; X Wang; C Mitchell; M A Kliewer; R J Dempsey
Journal:  Phys Med Biol       Date:  2012-10-18       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.