Literature DB >> 23239536

High friction moments in large hard-on-hard hip replacement bearings in conditions of poor lubrication.

Nicholas E Bishop1, Arne Hothan, Michael M Morlock.   

Abstract

Disappointing clinical results for large diameter metal replacement bearings for the hip are related to compromised lubrication due to poor cup placement, which increases wear as well as friction moments. The latter can cause overload of the implant-bone interfaces and the taper junction between head and stem. We investigated the influence of lubrication conditions on friction moments in modern hip bearings. Friction moments for large diameter metal and ceramic bearings were measured in a hip simulator with cup angles varying from 0° to 60°. Two diameters were tested for each bearing material, and measurements were made in serum and in dry conditions, representing severely compromised lubrication. Moments were lower for the ceramic bearings than for the metal bearings in lubricated conditions, but approached those for metal bearings at high cup inclination. In dry conditions, friction moments increased twofold to 12 Nm for metal bearings. For ceramic bearings, the increase was more than fivefold to over 25 Nm. Although large diameter ceramic bearings demonstrate an improvement in friction characteristics in the lubricated condition, they could potentially replicate problems currently experienced due to high friction moments in metal bearings once lubrication is compromised.
Copyright © 2012 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23239536     DOI: 10.1002/jor.22255

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  19 in total

1.  CORR Insights(®): Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Philip C Noble
Journal:  Clin Orthop Relat Res       Date:  2015-08-21       Impact factor: 4.176

2.  Taper design affects failure of large-head metal-on-metal total hip replacements.

Authors:  Nader A Nassif; Danyal H Nawabi; Kirsten Stoner; Marcella Elpers; Timothy Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

Review 3.  Corrosion of the Head-Stem Taper Junction-Are We on the Verge of an Epidemic?: Review Article.

Authors:  Michael Morlock; Dennis Bünte; Julian Gührs; Nicholas Bishop
Journal:  HSS J       Date:  2016-09-20

4.  Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Georgios K Triantafyllopoulos; Marcella E Elpers; Jayme C Burket; Christina I Esposito; Douglas E Padgett; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

5.  601 metal-on-metal total hip replacements with 36 mm heads a 5 minimum year follow up: Levels of ARMD remain low despite a comprehensive screening program.

Authors:  Amit Atrey; Alister Hart; Nasir Hussain; Jonathon Waite; Andrew J Shepherd; Steve Young
Journal:  J Orthop       Date:  2016-10-31

Review 6.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

7.  How screw connections influence the primary stability of acetabular cups under consideration of different bone models.

Authors:  Gafar Adam Ahmed; Linda Auge; Jessica Loke; Carlos Alfonso Fonseca Ulloa; Christian Fölsch; Markus Rickert; Bernd Alexander Ishaque; Alexander Jahnke
Journal:  J Orthop       Date:  2020-06-06

8.  The lubrication performance of the ceramic-on-ceramic hip implant under starved conditions.

Authors:  Qingen Meng; Jing Wang; Peiran Yang; Zhongmin Jin; John Fisher
Journal:  J Mech Behav Biomed Mater       Date:  2015-06-10

9.  Quantification of the Contact Area at the Head-Stem Taper Interface of Modular Hip Prostheses.

Authors:  Florian Witt; Julian Gührs; Michael M Morlock; Nicholas E Bishop
Journal:  PLoS One       Date:  2015-08-17       Impact factor: 3.240

10.  Hard-on-hard lubrication in the artificial hip under dynamic loading conditions.

Authors:  Robert Sonntag; Jörn Reinders; Johannes S Rieger; Daniel W W Heitzmann; J Philippe Kretzer
Journal:  PLoS One       Date:  2013-08-07       Impact factor: 3.240

View more